Filter interviews by
Clear (1)
I applied via Naukri.com and was interviewed in May 2021. There were 3 interview rounds.
The code used in RMC refers to the various standards and regulations followed in the Quality Control (QC) process.
ISO 9001:2015 - Quality Management System
ISO 13485:2016 - Medical devices - Quality management systems
FDA 21 CFR Part 820 - Quality System Regulation for medical devices
ICH Q7 - Good Manufacturing Practice Guide for Active Pharmaceutical Ingredients
ASTM E2500 - Standard Guide for Specification, Design, and ...
IS code stands for Indian Standard code and is a set of standards established by the Bureau of Indian Standards (BIS) for various products and services.
IS 456:2000 - Code of practice for plain and reinforced concrete
IS 2062:2011 - Specification of steel for general structural purposes
IS 1343:2012 - Code of practice for prestressed concrete
IS 1608:2005 - Mechanical testing of metals
IS 302-2-24:1992 - Safety of household...
Top trending discussions
I applied via Recruitment Consultant and was interviewed in Jun 2019. There were 3 interview rounds.
Concrete mix design involves determining the proportions of ingredients to create a specific concrete mixture.
The mix design process considers factors such as strength, workability, and durability.
Ingredients typically include cement, water, aggregates, and admixtures.
The proportions of each ingredient are determined based on the desired properties of the concrete and the specific application.
For example, a mix designe...
I applied via Company Website and was interviewed in Nov 2019. There were 3 interview rounds.
I applied via Approached by Company and was interviewed before Mar 2021. There was 1 interview round.
I applied via Company Website and was interviewed in Oct 2020. There were 4 interview rounds.
I applied via Company Website and was interviewed before Jan 2021. There were 4 interview rounds.
Fcao affects the setting time, strength, and durability of cement.
Fcao (free lime) is a byproduct of cement hydration.
Excess fcao can lead to delayed setting time and reduced strength.
Insufficient fcao can result in quick setting and decreased durability.
Optimal fcao content ensures proper hydration and desired cement properties.
based on 2 reviews
Rating in categories
Assistant Manager
527
salaries
| ₹0 L/yr - ₹0 L/yr |
Deputy Manager
199
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Executive
122
salaries
| ₹0 L/yr - ₹0 L/yr |
Sales Executive
72
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Sales Manager
70
salaries
| ₹0 L/yr - ₹0 L/yr |
UltraTech Cement
ACC
Ambuja Cements
Shree Cement