There are several types of valves in instrumentation.
Gate valve
Ball valve
Butterfly valve
Globe valve
Check valve
Diaphragm valve
Needle valve
Plug valve
Pressure relief valve
Safety valve
PT, LT and LVDT are types of sensors used in engineering for measuring pressure, temperature and displacement respectively.
PT stands for Pressure Transducer and is used to measure pressure in various applications such as hydraulic systems, engines, and pipelines.
LT stands for Linear Transducer and is used to measure temperature in various applications such as engines, HVAC systems, and industrial processes.
LVDT stands ...
Calibration of I/P converter involves adjusting the output pressure to match the input signal.
Connect the I/P converter to a pressure source and a signal generator
Adjust the input signal to the desired value
Measure the output pressure and adjust it to match the input signal
Repeat the process at different input signal levels to ensure accuracy
Document the calibration results for future reference
A load cell is a transducer that converts force into an electrical signal. Calibration involves applying known loads and adjusting the output signal.
Load cell measures force or weight
It converts the force into an electrical signal
Calibration involves applying known loads and adjusting the output signal
Calibration can be done using a calibration machine or weights
Calibration should be done regularly to ensure accurate r
posted on 13 Apr 2022
I applied via Campus Placement and was interviewed before Apr 2021. There were 2 interview rounds.
Journal knowledge of plastic raw material and their defect
I appeared for an interview before Jan 2022.
SCADA can be configured by setting up communication protocols, defining data points, creating graphical interfaces, and configuring alarms.
Set up communication protocols such as Modbus, DNP3, or OPC to communicate with field devices
Define data points by specifying the tags for each device or sensor being monitored
Create graphical interfaces by designing screens that display real-time data in a user-friendly format
Confi...
I/O modules can be configured by setting up the input and output signals, assigning addresses, and configuring communication protocols.
Identify the type of I/O module being used (analog, digital, etc.)
Assign addresses to the input and output signals for communication
Configure the communication protocols such as Modbus, Profibus, etc.
Set up the parameters for data transmission and reception
Test the configured I/O module
Assigning an IP address involves configuring the network settings of a device to enable communication with other devices on the same network.
Access the network settings of the device
Choose a suitable IP address based on the network's subnet
Assign the IP address along with subnet mask and default gateway
Ensure no IP address conflicts with other devices on the network
Save the settings and test the connection
I appeared for an interview before Feb 2024.
Math resoning english gk
I applied via Naukri.com and was interviewed before Sep 2023. There were 2 interview rounds.
Seeking new challenges and opportunities for growth
Looking for a new challenge to further develop my skills and experience
Interested in taking on more responsibilities and leadership roles
Seeking opportunities for career advancement and professional development
Experienced maintenance supervisor with strong leadership skills and a proven track record of successfully managing maintenance operations.
Over 5 years of experience in supervising maintenance teams
Skilled in developing and implementing maintenance schedules
Proven ability to troubleshoot and resolve maintenance issues efficiently
Strong communication and interpersonal skills
Led a team of 10 maintenance technicians at pr
I applied via Approached by Company and was interviewed in Dec 2024. There was 1 interview round.
Line balancing is the process of assigning tasks to workstations in a way that evens out the workload and maximizes efficiency.
Line balancing aims to minimize idle time and bottlenecks by distributing work evenly across workstations.
It involves analyzing the production process to determine the optimal sequence of tasks and the appropriate number of workers at each workstation.
For example, in a manufacturing plant, line...
Kaizen is a Japanese business philosophy of continuous improvement involving all employees.
Kaizen focuses on making small, incremental changes to processes to improve efficiency and quality.
It involves employees at all levels of the organization in identifying and implementing improvements.
Kaizen promotes a culture of continuous learning and innovation.
Examples of kaizen include implementing a new workflow to reduce wa...
based on 3 reviews
Rating in categories
Production Supervisor
532
salaries
| ₹1.9 L/yr - ₹5.5 L/yr |
Junior Officer
387
salaries
| ₹2.5 L/yr - ₹6 L/yr |
Production Officer
238
salaries
| ₹3 L/yr - ₹6.5 L/yr |
Operation Assistant
211
salaries
| ₹2.5 L/yr - ₹4.5 L/yr |
Management Assistant
208
salaries
| ₹3 L/yr - ₹7.5 L/yr |
Bosch
Samvardhana Motherson Group
Ceat Tyres
UNO Minda