Hard work versus smart work.
The power plug earth wire is bigger in size to ensure safety and prevent electrical shocks.
The earth wire provides a path for the current to flow in case of a fault or short circuit.
A larger wire size reduces resistance and allows for the safe dissipation of excess current.
It helps to protect individuals and equipment from electric shock hazards.
The earth wire is connected to the ground, which acts as a reference point...
Copper (Cu) conductor will take larger current than Aluminum (Al) conductor of the same size.
Copper has a higher electrical conductivity than Aluminum.
Copper has a lower resistivity than Aluminum.
Copper has better thermal conductivity than Aluminum.
Copper is more commonly used in high-current applications.
Aluminum is often used in overhead power transmission lines due to its lighter weight.
Pulse width modulation (PWM) is a technique used in VFD to control the speed of the motor by adjusting the width of the pulses of voltage supplied to the motor.
PWM is a method of controlling the amount of power delivered to a load without changing the voltage level.
In VFD, PWM is used to control the speed of the motor by varying the width of the pulses of voltage supplied to the motor.
The width of the pulses is control...
I applied via Walk-in and was interviewed before Dec 2019. There were 4 interview rounds.
Disputes can be resolved through negotiation, mediation, arbitration or litigation.
Negotiation involves discussion and compromise to reach a mutually acceptable solution.
Mediation involves a neutral third party who helps the parties reach a settlement.
Arbitration involves a neutral third party who makes a binding decision after hearing both sides.
Litigation involves taking the dispute to court and having a judge or jur...
Mecon interview questions for popular designations
posted on 9 Jan 2018
Get interview-ready with Top Mecon Interview Questions
Internal combustion engines burn fuel inside the engine while external combustion engines burn fuel outside the engine.
Internal combustion engines are commonly used in cars, motorcycles, and airplanes.
External combustion engines are less common and include steam engines and Stirling engines.
Internal combustion engines are more efficient and powerful than external combustion engines.
External combustion engines are typic...
DC motor works on the principle of Lorentz force.
DC motor converts electrical energy into mechanical energy.
It consists of a rotor and a stator.
When current flows through the coil, it produces a magnetic field.
The magnetic field interacts with the magnetic field of the permanent magnet, producing a torque that rotates the rotor.
The direction of rotation can be reversed by reversing the direction of current flow.
Commutator is a device used in electric motors to convert AC to DC.
It consists of a set of copper segments attached to the rotor of the motor.
It helps in reversing the direction of current flow in the armature winding.
It ensures that the torque produced by the motor is unidirectional.
Examples include DC motors, generators, and some types of welding machines.
Back EMF is directly proportional to speed and number of poles in a DC motor.
Back EMF is generated in the opposite direction to the applied voltage.
As the motor speeds up, the back EMF increases.
The number of poles in the motor determines the frequency of the back EMF.
More poles result in a higher frequency and a smoother rotation.
Back EMF is used to control the speed of the motor.
Slipring and squirrel cage induction motors differ in their rotor construction and starting torque.
Slipring motor has a wound rotor with slip rings and brushes while squirrel cage motor has a simple rotor with bars and end rings.
Slipring motor has high starting torque and can be used for heavy loads while squirrel cage motor has low starting torque and is suitable for light loads.
Slipring motor can be controlled by var...
Synchronous motors rotate at a fixed speed while slipring induction motors have variable speed.
Synchronous motors have a constant speed and require an external power source to start
Slipring induction motors have a variable speed and can start on their own
Synchronous motors are used in applications where constant speed is required, such as in clocks and timers
Slipring induction motors are used in applications where vari...
Speed, frequency and number of poles are interrelated in a 3-phase induction motor.
The speed of the motor is directly proportional to the frequency of the power supply.
The number of poles in the motor determines the speed at which it operates.
For a given frequency, the speed of the motor decreases as the number of poles increases.
For a given number of poles, the speed of the motor increases as the frequency of the powe
Fleming's left-hand rule states that the direction of motion of a DC motor is perpendicular to both the magnetic field and the direction of current flow.
Fleming's left-hand rule is used to determine the direction of motion of a DC motor.
The rule states that the direction of motion is perpendicular to both the magnetic field and the direction of current flow.
The thumb represents the direction of motion, the first finger...
Yes, I play video games in my free time.
I enjoy playing action-adventure games like Assassin's Creed and Uncharted.
I also like playing sports games like FIFA and NBA 2K.
Sometimes I play puzzle games like Tetris or Candy Crush.
Playing video games helps me relax and unwind after a long day.
My native place is famous for its ancient temples and rich cultural heritage.
The city has a famous temple dedicated to Lord Shiva
The annual cultural festival attracts tourists from all over the world
The city is known for its traditional dance forms and music
The local cuisine is a blend of different flavors and spices
The city has a rich history dating back to the ancient times
Top trending discussions
The duration of Mecon interview process can vary, but typically it takes about less than 2 weeks to complete.
based on 35 interviews
Interview experience
Assistant Project Engineer
370
salaries
| ₹2.6 L/yr - ₹7 L/yr |
Executive
170
salaries
| ₹5.8 L/yr - ₹13.5 L/yr |
Executive Engineer
98
salaries
| ₹5 L/yr - ₹12 L/yr |
Project Engineer
83
salaries
| ₹3.5 L/yr - ₹10 L/yr |
Senior Manager
50
salaries
| ₹13 L/yr - ₹30 L/yr |
Engineers India
BHEL
TCS
Larsen & Toubro Limited