i
Larsen & Toubro Limited
Proud winner of ABECA 2024 - AmbitionBox Employee Choice Awards
Filter interviews by
I electrical good work All electrical Equipment and HT and LT Breker And 3.3 kv SF6 Breker transformer work and 440 volt terminition work cable jointing work
ALL ELECTRICAL WORK HT LT Breker VCB ACB CT GO and Transformer etc
What people are saying about Larsen & Toubro Limited
I applied via Company Website
Electrician test and all questions
I applied via Walk-in and was interviewed in Oct 2023. There was 1 interview round.
ELCB stands for Earth Leakage Circuit Breaker and MCB stands for Miniature Circuit Breaker.
ELCB is a safety device used to protect against electrical shock caused by earth faults.
MCB is a type of circuit breaker that automatically switches off electrical circuits during abnormal conditions.
ELCB detects current leakage to earth and disconnects the circuit, while MCB protects against overloads and short circuits.
MCB (Miniature Circuit Breaker) provides overload protection by automatically switching off the circuit when current exceeds the rated capacity.
MCB trips when current exceeds its rated capacity to prevent overheating and potential fire hazards.
Overload protection is essential to protect electrical appliances and wiring from damage.
Examples of MCB overload protection include tripping when too many devices are connected ...
posted on 22 Apr 2024
posted on 14 Jan 2023
I applied via Indeed and was interviewed in Dec 2022. There were 2 interview rounds.
An electrical panel with a braking system is a safety feature that automatically stops the flow of electricity in case of an emergency or malfunction.
The braking system in an electrical panel is designed to prevent electrical accidents and protect both people and equipment.
It works by detecting abnormal conditions such as short circuits, overloads, or ground faults, and immediately cutting off the power supply.
This hel...
I applied via Walk-in and was interviewed in Sep 2023. There were 2 interview rounds.
I applied via Newspaper Ad and was interviewed in Mar 2024. There were 2 interview rounds.
Glanding termination
Sefty test safety code
posted on 31 Dec 2021
I applied via Recruitment Consultant and was interviewed in Dec 2021. There was 1 interview round.
Interview experience
based on 107 reviews
Rating in categories
Assistant Manager
3.9k
salaries
| ₹6.5 L/yr - ₹18 L/yr |
Senior Engineer
3.4k
salaries
| ₹4.5 L/yr - ₹12.5 L/yr |
Engineer
1.2k
salaries
| ₹1.6 L/yr - ₹9.3 L/yr |
Manager
1.1k
salaries
| ₹9.6 L/yr - ₹30 L/yr |
Assistant Construction Manager
1k
salaries
| ₹6 L/yr - ₹21 L/yr |
Tata Group
Reliance Industries
Adani Group
Mahindra & Mahindra