Filter interviews by
I appeared for an interview in Feb 2017.
I am a graduate with a passion for sales and marketing. I am open to being placed anywhere in India. I have knowledge about your company and am excited to learn more.
Graduate with sales and marketing background
Open to being placed anywhere in India
Familiar with the company and eager to learn more
Knowledgeable about pass book balance and cash book
Understanding of working capital and current ratio
Top trending discussions
posted on 28 May 2022
I applied via LinkedIn and was interviewed before May 2021. There were 2 interview rounds.
Good
posted on 1 Feb 2015
posted on 22 Apr 2024
I applied via Approached by Company and was interviewed in Mar 2024. There was 1 interview round.
posted on 17 Oct 2021
I appeared for an interview in Sep 2021.
posted on 11 Mar 2023
I applied via Campus Placement and was interviewed in Sep 2022. There were 2 interview rounds.
LSM and WSM are two different methods of measuring soil moisture content.
LSM stands for Laboratory Soil Moisture and WSM stands for Field Water Content.
LSM measures the moisture content of soil samples in a laboratory setting.
WSM measures the water content of soil in the field using various methods such as gravimetric, neutron probe, and time domain reflectometry.
LSM is more accurate but time-consuming, while WSM is le...
posted on 18 Jul 2022
I applied via Campus Placement
posted on 31 Jul 2024
I applied via Campus Placement and was interviewed before Jul 2023. There were 2 interview rounds.
The very first round was Online Assessment( Aptitude+Technical - MCQs).
posted on 11 Mar 2023
I applied via Approached by Company and was interviewed before Mar 2022. There was 1 interview round.
posted on 14 Jun 2021
Transformer losses refer to the energy dissipated in a transformer during its operation.
Transformer losses include copper losses and iron losses.
Copper losses occur due to the resistance of the transformer windings.
Iron losses, also known as core losses, occur due to hysteresis and eddy currents in the transformer core.
Copper losses can be minimized by using larger conductor sizes and reducing the resistance of winding...
Neutral is grounded in star connected transformer for safety and to limit voltage rise.
Grounding neutral limits voltage rise in case of unbalanced loads.
It provides a path for fault current to flow, which helps in detecting and isolating faults.
It reduces the risk of electric shock to personnel and damage to equipment.
In some countries, it is a legal requirement to ground the neutral in electrical systems.
Example: In a...
Power is the rate at which energy is transferred, while energy is the ability to do work.
Power is measured in watts, while energy is measured in joules.
Power is the rate at which energy is used or transferred, while energy is the capacity to do work.
A light bulb may have a power rating of 60 watts, but the energy it consumes over time is measured in watt-hours.
Energy can exist in different forms, such as kinetic, poten...
IGBT stands for Insulated Gate Bipolar Transistor, a power semiconductor device used for switching and amplification of electrical power.
IGBT is a three-terminal device with a collector, emitter, and gate.
It combines the advantages of MOSFET and BJT transistors.
It is commonly used in high power applications such as motor drives, power supplies, and renewable energy systems.
IGBTs have low on-state voltage drop and high ...
Relay is an electrically operated switch that uses an electromagnet to mechanically open or close a circuit.
Relays are used to control high voltage or high current circuits with low voltage signals.
They are commonly used in industrial automation, automotive applications, and household appliances.
Relays can be classified into different types based on their construction and operation, such as electromagnetic relays, soli...
CT and PT are connected in circuit to measure current and voltage respectively.
CT is connected in series with the load to measure current
PT is connected in parallel with the load to measure voltage
CT and PT are used together to measure power in a circuit
The ratio of CT and PT is important for accurate measurement
Solar PV modules convert sunlight into electricity using photovoltaic effect.
Solar PV modules consist of multiple solar cells connected in series and parallel.
Each solar cell is made of semiconductor material, usually silicon.
When sunlight hits the solar cell, it excites the electrons in the semiconductor material, creating a flow of electricity.
The electricity generated by the solar cells is direct current (DC), which...
In Star connection, line voltage is equal to the square root of 3 times phase voltage.
Line voltage is the voltage between any two line conductors in a three-phase system.
Phase voltage is the voltage between any line conductor and the neutral point in a three-phase system.
In a Star connection, all three phases are connected to a common neutral point.
The relationship between line voltage and phase voltage in Star connect...
Site Engineer
120
salaries
| ₹2 L/yr - ₹6 L/yr |
Senior Engineer
88
salaries
| ₹3.8 L/yr - ₹8.5 L/yr |
Civil Site Engineer
62
salaries
| ₹1.8 L/yr - ₹5.8 L/yr |
QA QC Engineer
51
salaries
| ₹1.8 L/yr - ₹6.6 L/yr |
MEP Engineer
49
salaries
| ₹1.4 L/yr - ₹7 L/yr |
Sterling & Wilson
Nasser S. Al Hajri Corporation
Ramky Infrastructure
Dodsal Engineering & Construction