I applied via Referral and was interviewed before Jun 2022. There were 3 interview rounds.
Top trending discussions
What is the colume
The vertical part of the building and base of the slab, distribution of load
posted on 19 Jan 2024
I applied via Naukri.com and was interviewed in Dec 2023. There was 1 interview round.
posted on 12 Mar 2024
I applied via Walk-in and was interviewed in Feb 2024. There were 2 interview rounds.
SOLAR ENERGY RELETED CIVIL CONSTRUCTION DISCUSSION
Solar system refers to the collection of planets and other objects that orbit around a star, typically referring to our own solar system with the Sun at its center.
The solar system consists of the Sun, eight planets, moons, asteroids, comets, and other celestial bodies.
The planets in our solar system are Mercury, Venus, Earth, Mars, Jupiter, Saturn, Uranus, and Neptune.
The Sun is the central star of our solar system, p...
posted on 15 Sep 2023
I applied via Job Portal and was interviewed in Aug 2023. There were 2 interview rounds.
The minimum cement content in RCC structure is typically around 300 kg/m3.
Minimum cement content is usually specified by structural engineers based on design requirements.
Higher cement content may be required for structures in aggressive environments or with special design considerations.
The minimum cement content is important for achieving the desired strength and durability of the concrete mix.
The shape of slump in a slump cone test is typically conical.
The shape of slump is conical, with the top being wider than the base.
The height of the slump is measured to determine the workability of the concrete.
Different types of slumps (true slump, shear slump, collapse slump) indicate different levels of workability.
Example: A true slump has a smooth, symmetrical shape with a slight collapse at the center.
Lapping zone of column is where two reinforcement bars overlap to ensure continuity of load transfer.
Lapping zone should be at least 50 times the diameter of the smaller bar away from the face of the support.
Proper lapping length is crucial for structural integrity and load distribution.
Lapping should be staggered in multiple layers for better strength.
Ensure proper cover and clear spacing around the lapping zone to pr
posted on 11 Mar 2024
I applied via Recruitment Consulltant and was interviewed in Sep 2023. There was 1 interview round.
Mandatory PPE in electrical work includes insulated gloves, safety glasses, and hard hats.
Insulated gloves are essential to protect against electric shock.
Safety glasses protect the eyes from potential hazards like sparks or debris.
Hard hats are necessary to prevent head injuries from falling objects or electrical hazards.
HIRA stands for Hazard Identification and Risk Assessment. Piling hazards include collapse, falling objects, noise, and vibration. Control measures include proper training, PPE, and regular inspections.
HIRA stands for Hazard Identification and Risk Assessment
Piling hazards include collapse, falling objects, noise, and vibration
Control measures include proper training for workers
Control measures include providing approp...
posted on 27 Sep 2023
I applied via Referral and was interviewed before Sep 2022. There were 2 interview rounds.
System studies involve analyzing and evaluating the performance of electrical systems to ensure efficiency and reliability.
System studies involve analyzing the behavior of electrical systems under different operating conditions.
They help identify potential issues and optimize the performance of the system.
Examples of system studies include load flow analysis, short circuit analysis, and protection coordination studies.
Load flow study is a method used in electrical engineering to analyze and calculate the flow of power in an electrical network.
Load flow study helps in determining the steady-state operating conditions of a power system.
It involves calculating the voltage magnitude and phase angle at each bus in the network.
The study considers factors like power generation, transmission line losses, and load demand.
It helps in identify...
The hydrotest pressure is 1.5 times the design pressure.
Hydrotest pressure is the pressure applied to a vessel or pipeline to check for leaks or defects.
It is usually done before commissioning the system.
For example, if the design pressure is 100 psi, the hydrotest pressure would be 150 psi.
The procedure for fit up inspection includes classification, cleaning, alignment, root gap, root face, bevel angle, and mismatch or overlap.
Classify the base metal
Clean the surface
Align the parts to be joined
Check the root gap and root face
Measure the bevel angle
Check for any mismatch or overlap
Ensure all specifications are met
Senior Engineer
27
salaries
| ₹3.5 L/yr - ₹9 L/yr |
Assistant Manager
22
salaries
| ₹5.6 L/yr - ₹14 L/yr |
Engineer
11
salaries
| ₹2.5 L/yr - ₹4.5 L/yr |
Structural Engineer
10
salaries
| ₹5.2 L/yr - ₹7.5 L/yr |
Production Engineer
10
salaries
| ₹3.3 L/yr - ₹5 L/yr |
Tata Projects
Larsen & Toubro Limited
Shapoorji Pallonji Group
Simplex Infrastructures