Filter interviews by
I applied via Job Portal and was interviewed in Aug 2023. There were 3 interview rounds.
The minimum cement content in RCC structure is typically around 300 kg/m3.
Minimum cement content is usually specified by structural engineers based on design requirements.
Higher cement content may be required for structures in aggressive environments or with special design considerations.
The minimum cement content is important for achieving the desired strength and durability of the concrete mix.
The shape of slump in a slump cone test is typically conical.
The shape of slump is conical, with the top being wider than the base.
The height of the slump is measured to determine the workability of the concrete.
Different types of slumps (true slump, shear slump, collapse slump) indicate different levels of workability.
Example: A true slump has a smooth, symmetrical shape with a slight collapse at the center.
Lapping zone of column is where two reinforcement bars overlap to ensure continuity of load transfer.
Lapping zone should be at least 50 times the diameter of the smaller bar away from the face of the support.
Proper lapping length is crucial for structural integrity and load distribution.
Lapping should be staggered in multiple layers for better strength.
Ensure proper cover and clear spacing around the lapping zone to pr
Top trending discussions
posted on 29 Jan 2021
posted on 20 Dec 2020
I applied via Naukri.com and was interviewed in Jan 2021. There were 3 interview rounds.
Precommissioning tests of transformers ensure proper functioning and safety before energizing.
Visual inspection of transformer and its components
Measurement of insulation resistance
Measurement of winding resistance
Verification of transformer ratio and polarity
Verification of oil level and quality
Testing of protective devices
Verification of grounding
Functional testing of cooling system
Verification of nameplate data
11kv & 33kv overhead power line distribution
11kv and 33kv are common voltage levels for overhead power lines
Overhead power lines are used to distribute electricity from power stations to consumers
The voltage level determines the distance the power can be transmitted and the size of the conductors needed
Proper insulation and grounding is important for safety
Maintenance and inspection of the lines is necessary to ensure
The size of a concrete cube is typically 150mm x 150mm x 150mm for standard testing purposes.
Standard size for concrete cube is 150mm x 150mm x 150mm
Used for testing the compressive strength of concrete
Other sizes may be used for specific projects or requirements
posted on 30 Aug 2021
I applied via Naukri.com and was interviewed in Aug 2021. There were 3 interview rounds.
posted on 1 Oct 2023
I applied via Walk-in and was interviewed in Apr 2023. There were 3 interview rounds.
posted on 16 Sep 2022
I applied via Company Website and was interviewed in Aug 2022. There was 1 interview round.
Slump test is a measure of the consistency of fresh concrete.
It is used to determine the workability of concrete.
The test involves filling a standard cone-shaped container with concrete and then removing the cone to see how much the concrete slumps or settles.
The amount of slump is measured in millimeters and indicates the wetness or dryness of the concrete.
Curing is the process of maintaining moisture in the concrete ...
posted on 20 Dec 2023
The density of RCC structure typically ranges from 2200 to 2500 kg/m^3.
Density of RCC is influenced by the type and proportion of materials used.
Common density range for RCC is 2200 to 2500 kg/m^3.
Higher density indicates stronger and more durable RCC structure.
posted on 12 Sep 2021
based on 5 interviews
Interview experience
based on 1 review
Rating in categories
Civil Site Engineer
16
salaries
| ₹2.9 L/yr - ₹5.8 L/yr |
Civil Engineer
13
salaries
| ₹2.4 L/yr - ₹6.5 L/yr |
Site Engineer
7
salaries
| ₹2 L/yr - ₹7 L/yr |
Senior Engineer
6
salaries
| ₹6.8 L/yr - ₹11.4 L/yr |
Senior Legal Officer
6
salaries
| ₹9 L/yr - ₹18 L/yr |
L&T Construction
Simplex Infrastructures
ITD Cementation India
Ashoka Buildcon