Filter interviews by
I was interviewed in Jul 2024.
Factors that increase plant efficiency include technology upgrades, maintenance practices, employee training, and energy management strategies.
Investing in technology upgrades to improve equipment performance and reduce energy consumption
Implementing regular maintenance practices to ensure equipment operates at peak efficiency
Providing employee training to optimize plant operations and reduce downtime
Implementing energ...
Coal pyrolysis is the process of heating coal in the absence of oxygen to break it down into simpler compounds.
Coal pyrolysis involves heating coal at high temperatures (typically 400-800 degrees Celsius) in the absence of oxygen.
During pyrolysis, coal breaks down into volatile gases, tar, and char.
The volatile gases can be used as fuel or chemical feedstock, while the tar and char can be further processed into various...
CFR stands for Code of Federal Regulations, a set of rules published by the federal government of the United States.
CFR is a collection of regulations that govern various aspects of federal law in the United States.
It is organized by subject matter into 50 titles, each covering a specific area of law.
CFR is updated annually and is available online for public access.
It is used by government agencies, businesses, and ind...
The number of fire balls in an MHI boiler varies depending on the size and model of the boiler.
The number of fire balls in an MHI boiler can range from 1 to 8 or more, depending on the specific design and capacity of the boiler.
The size and capacity of the boiler will determine the number of fire balls needed to efficiently heat the water and produce steam.
For example, a smaller MHI boiler may have 1 or 2 fire balls, w...
Turbine heat rate is a measure of how efficiently a turbine converts fuel into electricity.
Turbine heat rate is the amount of fuel energy required to produce one unit of electricity (typically expressed in BTU/kWh or kJ/kWh).
A lower heat rate indicates higher efficiency, as less fuel is needed to generate the same amount of electricity.
Factors affecting turbine heat rate include turbine design, operating conditions, an
Seeking new challenges and opportunities for growth.
Desire for career advancement
Looking for new challenges
Opportunity for professional growth
Change in company culture or values
Relocation to a new area
The good thing in my present company is the supportive and collaborative work environment.
Supportive and collaborative work environment
Opportunities for growth and development
Strong leadership and communication
Positive company culture
I have 5 years of experience as a Unit Controller and I am expecting a CTC of $80,000 per annum.
5 years of experience as a Unit Controller
Expected CTC of $80,000 per annum
Strong understanding of financial analysis and reporting
Experience in budgeting and forecasting
Proficient in financial software and tools
I applied via Referral and was interviewed in Mar 2024. There was 1 interview round.
My letter writing skills are strong and professional.
I have experience drafting formal letters, emails, and reports in my previous roles.
I pay attention to detail, grammar, and formatting to ensure clear and effective communication.
I am able to tailor my writing style to suit the audience and purpose of the communication.
I have received positive feedback on my written communication skills from colleagues and supervisor
I rate myself 8 out of 10 in advance excel skills.
Proficient in creating complex formulas and functions
Skilled in data analysis and visualization using pivot tables and charts
Experienced in VLOOKUP, INDEX-MATCH, and conditional formatting
Familiar with macros and automation in Excel
Continuous learning and improvement in advanced Excel techniques
I applied via Walk-in and was interviewed in Apr 2024. There was 1 interview round.
Hydraulic diagnosis involves identifying and fixing issues with hydraulic systems in diesel engines.
Check for leaks in the hydraulic system
Inspect hydraulic fluid levels and quality
Test hydraulic pressure and flow rates
Look for damaged or worn hydraulic components
Use diagnostic tools like pressure gauges and flow meters
Consult manufacturer's guidelines for troubleshooting
Consider potential causes such as air in the sys
I applied via Campus Placement
Jaiprakash Power Ventures interview questions for popular designations
Get interview-ready with Top Jaiprakash Power Ventures Interview Questions
I applied via Walk-in and was interviewed before Oct 2023. There were 2 interview rounds.
Subjective regarding self and your experience
I applied via Walk-in and was interviewed in Aug 2022. There was 1 interview round.
I applied via Approached by Company and was interviewed before Jan 2023. There was 1 interview round.
The type of excitation system in a generator determines how the generator is powered and controlled.
There are mainly two types of excitation systems: static excitation system and brushless excitation system.
Static excitation systems use a separate DC power source to provide the field current to the generator.
Brushless excitation systems use the generator's own output to power the field winding.
Each type of excitation s...
Buchholz Relay is a protective device used in oil-filled transformers to detect faults such as internal arcing or overheating.
Monitors oil flow in transformer
Detects faults like internal arcing or overheating
Triggers alarm or trips circuit if fault detected
I applied via Naukri.com and was interviewed before Apr 2023. There was 1 interview round.
Kirchhoff's law states that the total current entering a junction must equal the total current leaving the junction.
Kirchhoff's current law (KCL) is based on the principle of conservation of charge.
It is used to analyze electrical circuits and determine unknown currents.
Mathematically, KCL is expressed as the sum of currents entering a node equals the sum of currents leaving the node.
Top trending discussions
Interview experience
based on 183 reviews
Rating in categories
Senior Engineer
50
salaries
| ₹5.5 L/yr - ₹9.4 L/yr |
Plant Engineer
48
salaries
| ₹7 L/yr - ₹12.6 L/yr |
Engineer
38
salaries
| ₹3.9 L/yr - ₹8 L/yr |
Deputy Chief Engineer
31
salaries
| ₹7.8 L/yr - ₹12 L/yr |
Electrical Engineer
24
salaries
| ₹4.1 L/yr - ₹7.1 L/yr |
NTPC
Tata Power
Adani Power
NHPC