Filter interviews by
posted on 21 Dec 2024
I applied via Referral and was interviewed in Nov 2024. There were 3 interview rounds.
I have 3 years of experience working as a Supply Chain Analyst for a large retail company.
Managed inventory levels to ensure optimal stock levels and minimize excess inventory
Analyzed supply chain data to identify trends and make recommendations for process improvements
Collaborated with vendors to negotiate pricing and terms for supply contracts
2 excel sheets where given, to analyze and interpret the data to give a better solution for the problem given
I chose this career because of my interest in data analysis and problem-solving in the supply chain industry.
Passion for data analysis and problem-solving
Interest in the supply chain industry
Opportunity for growth and advancement
Desire to make a positive impact on business operations
I applied via Company Website and was interviewed in Dec 2024. There were 2 interview rounds.
I applied via Walk-in and was interviewed in Jul 2024. There were 3 interview rounds.
posted on 11 Sep 2024
I was interviewed in Mar 2024.
Tell something about yourself.
HVAC stands for Heating, Ventilation, and Air Conditioning. It refers to the technology of indoor environmental comfort.
HVAC systems control temperature, humidity, and air quality in buildings.
Heating can be provided through furnaces, boilers, or heat pumps.
Ventilation involves exchanging indoor and outdoor air to improve air quality.
Air conditioning systems use refrigeration to cool indoor air.
HVAC systems are essenti...
Plumbing system refers to the network of pipes, fixtures, and fittings that deliver water and remove waste in a building.
Plumbing systems include pipes for water supply, drainage, and venting
Fixtures such as sinks, toilets, showers, and bathtubs are connected to the plumbing system
Plumbing systems also include valves, pumps, water heaters, and other equipment
Proper installation and maintenance of plumbing systems are e
FM 200 is a clean agent fire suppression system commonly used in data centers and other critical facilities.
FM 200 is a colorless, odorless gas that is stored in cylinders and discharged into the protected space in the event of a fire.
It works by reducing the oxygen levels in the air to a point where combustion is no longer sustainable.
FM 200 is non-toxic and leaves no residue, making it ideal for use in areas with sen...
LT panel room is a crucial part of electrical systems, housing electrical components for power distribution.
LT panel room is where the electrical distribution board is located for controlling and distributing power to various circuits.
Work sequence involves checking the incoming power supply, monitoring the load requirements, and ensuring proper distribution of power.
Regular maintenance and inspection of LT panel room ...
posted on 12 Dec 2024
I applied via Company Website and was interviewed in Oct 2023. There were 2 interview rounds.
Electrical and maintanance
There are several types of chillers used in facilities, including air-cooled, water-cooled, absorption, and centrifugal chillers.
Air-cooled chillers use air to remove heat from the refrigerant.
Water-cooled chillers use water to remove heat from the refrigerant.
Absorption chillers use a heat source, such as natural gas or steam, to drive the refrigeration cycle.
Centrifugal chillers use centrifugal force to compress the
Regular checks and maintenance are essential for ensuring the proper functioning of DG (Diesel Generator) systems.
Daily visual inspections for leaks, damages, and loose connections.
Weekly checks for fuel levels, coolant levels, and battery condition.
Monthly load testing to ensure the generator can handle the required load.
Annual maintenance including oil and filter changes, spark plug replacement, and thorough cleaning...
UPS stands for Uninterruptible Power Supply. There are three types of UPS: standby, line-interactive, and online.
UPS stands for Uninterruptible Power Supply.
UPS provides backup power to critical equipment during power outages or fluctuations.
The three types of UPS are standby, line-interactive, and online.
Standby UPS switches to battery power when the main power source fails.
Line-interactive UPS regulates voltage fluct...
Safety precautions before working
Conduct a thorough risk assessment of the work area
Ensure all necessary personal protective equipment (PPE) is available and worn
Implement proper training and education on safety procedures
Inspect and maintain tools and equipment regularly
Establish emergency response plans and procedures
Promote a culture of safety and encourage reporting of hazards or incidents
UPS (Uninterruptible Power Supply) safety measures include surge protection, battery backup, and automatic voltage regulation.
Surge protection safeguards electronic devices from power surges or spikes.
Battery backup provides temporary power during outages, preventing data loss or equipment damage.
Automatic voltage regulation stabilizes voltage levels, protecting equipment from fluctuations.
UPS systems may have audible ...
To maintain a transformer, regular inspections, cleaning, and testing are necessary.
Perform regular visual inspections to check for any signs of damage or leaks.
Clean the transformer regularly to remove dust, dirt, and debris.
Test the transformer's insulation resistance to ensure it is within acceptable limits.
Monitor the transformer's temperature and oil levels regularly.
Perform oil analysis to detect any potential is...
A 52-week schedule is a plan that outlines tasks, events, or milestones for each week of a year.
A 52-week schedule helps in organizing and managing tasks throughout the year.
It can be used in various industries such as project management, event planning, and manufacturing.
Each week of the schedule may include specific goals, deadlines, or activities.
Examples of 52-week schedules include construction project timelines, ...
A chiller is a refrigeration system used to cool large spaces, while a PAC (Portable Air Conditioner) is a compact unit used for localized cooling.
Chillers are typically used in commercial or industrial settings to cool large areas such as office buildings or factories.
PACs are smaller and more portable, designed to cool specific areas or rooms.
Chillers use a refrigeration cycle to remove heat from the air or water, wh...
A clean agent fire extinguisher is typically used in server rooms.
Clean agent fire extinguishers are designed to suppress fires without leaving residue or damaging sensitive equipment.
They use chemicals like halon, carbon dioxide, or clean agents like FM-200 or Novec 1230.
These extinguishers are effective in suppressing fires involving electrical equipment and are safe for use in server rooms.
It is important to consult...
6S is a workplace organization methodology that focuses on creating a clean, efficient, and safe environment.
6S stands for Sort, Set in Order, Shine, Standardize, Sustain, and Safety.
It is derived from the 5S methodology and adds an additional focus on safety.
Sort involves removing unnecessary items from the workplace.
Set in Order involves organizing and arranging necessary items in a logical manner.
Shine refers to cle...
I applied via Naukri.com and was interviewed in Sep 2023. There were 3 interview rounds.
The sequence of works in construction typically involves planning, site preparation, foundation work, structural construction, finishing touches, and final inspection.
Planning: Develop project plans, obtain permits, and create a timeline.
Site preparation: Clear the site, set up temporary facilities, and install utilities.
Foundation work: Excavate, pour footings, and construct foundation walls.
Structural construction: B...
based on 2 reviews
Rating in categories
JLL
CBRE
Square Yards
NoBroker