I appeared for an interview in Feb 2025, where I was asked the following questions.
In my previous role, I managed facility operations, ensuring efficiency and compliance with safety standards.
Oversaw daily operations of the facility, including maintenance and security.
Implemented energy-saving initiatives that reduced costs by 15%.
Coordinated with vendors for timely repairs and service contracts.
Led a team of 10 staff members, providing training and performance evaluations.
Developed and maintained em
I possess a diverse range of technical skills in facility management, including HVAC systems, electrical systems, and safety protocols.
Proficient in HVAC system maintenance and troubleshooting, ensuring optimal performance and energy efficiency.
Experienced in managing electrical systems, including wiring, circuit breakers, and lighting installations.
Skilled in implementing safety protocols and compliance measures, redu...
I applied via Company Website and was interviewed in Oct 2023. There were 2 interview rounds.
Electrical and maintanance
There are several types of chillers used in facilities, including air-cooled, water-cooled, absorption, and centrifugal chillers.
Air-cooled chillers use air to remove heat from the refrigerant.
Water-cooled chillers use water to remove heat from the refrigerant.
Absorption chillers use a heat source, such as natural gas or steam, to drive the refrigeration cycle.
Centrifugal chillers use centrifugal force to compress the
Regular checks and maintenance are essential for ensuring the proper functioning of DG (Diesel Generator) systems.
Daily visual inspections for leaks, damages, and loose connections.
Weekly checks for fuel levels, coolant levels, and battery condition.
Monthly load testing to ensure the generator can handle the required load.
Annual maintenance including oil and filter changes, spark plug replacement, and thorough cleaning...
UPS stands for Uninterruptible Power Supply. There are three types of UPS: standby, line-interactive, and online.
UPS stands for Uninterruptible Power Supply.
UPS provides backup power to critical equipment during power outages or fluctuations.
The three types of UPS are standby, line-interactive, and online.
Standby UPS switches to battery power when the main power source fails.
Line-interactive UPS regulates voltage fluct...
Safety precautions before working
Conduct a thorough risk assessment of the work area
Ensure all necessary personal protective equipment (PPE) is available and worn
Implement proper training and education on safety procedures
Inspect and maintain tools and equipment regularly
Establish emergency response plans and procedures
Promote a culture of safety and encourage reporting of hazards or incidents
UPS (Uninterruptible Power Supply) safety measures include surge protection, battery backup, and automatic voltage regulation.
Surge protection safeguards electronic devices from power surges or spikes.
Battery backup provides temporary power during outages, preventing data loss or equipment damage.
Automatic voltage regulation stabilizes voltage levels, protecting equipment from fluctuations.
UPS systems may have audible ...
To maintain a transformer, regular inspections, cleaning, and testing are necessary.
Perform regular visual inspections to check for any signs of damage or leaks.
Clean the transformer regularly to remove dust, dirt, and debris.
Test the transformer's insulation resistance to ensure it is within acceptable limits.
Monitor the transformer's temperature and oil levels regularly.
Perform oil analysis to detect any potential is...
A 52-week schedule is a plan that outlines tasks, events, or milestones for each week of a year.
A 52-week schedule helps in organizing and managing tasks throughout the year.
It can be used in various industries such as project management, event planning, and manufacturing.
Each week of the schedule may include specific goals, deadlines, or activities.
Examples of 52-week schedules include construction project timelines, ...
A chiller is a refrigeration system used to cool large spaces, while a PAC (Portable Air Conditioner) is a compact unit used for localized cooling.
Chillers are typically used in commercial or industrial settings to cool large areas such as office buildings or factories.
PACs are smaller and more portable, designed to cool specific areas or rooms.
Chillers use a refrigeration cycle to remove heat from the air or water, wh...
A clean agent fire extinguisher is typically used in server rooms.
Clean agent fire extinguishers are designed to suppress fires without leaving residue or damaging sensitive equipment.
They use chemicals like halon, carbon dioxide, or clean agents like FM-200 or Novec 1230.
These extinguishers are effective in suppressing fires involving electrical equipment and are safe for use in server rooms.
It is important to consult...
6S is a workplace organization methodology that focuses on creating a clean, efficient, and safe environment.
6S stands for Sort, Set in Order, Shine, Standardize, Sustain, and Safety.
It is derived from the 5S methodology and adds an additional focus on safety.
Sort involves removing unnecessary items from the workplace.
Set in Order involves organizing and arranging necessary items in a logical manner.
Shine refers to cle...
I applied via Naukri.com and was interviewed in Jan 2021. There were 3 interview rounds.
I applied via Recruitment Consultant and was interviewed in Sep 2019. There were 4 interview rounds.
CBRE interview questions for designations
Top trending discussions
I applied via Walk-in and was interviewed before Jun 2021. There were 2 interview rounds.
I applied via Walk-in and was interviewed before Sep 2021. There were 5 interview rounds.
Topic for group discussion was GST. I spoke in favour of GST.
posted on 27 Mar 2023
I applied via Walk-in and was interviewed in Sep 2022. There was 1 interview round.
I applied via Referral and was interviewed in Apr 2023. There were 3 interview rounds.
A fire alarm system is a network of devices designed to detect and alert people to the presence of a fire in a building.
Fire alarm systems typically consist of smoke detectors, heat detectors, alarms, and control panels.
When a fire is detected, the system activates alarms to alert occupants and authorities.
Modern fire alarm systems may also include features such as remote monitoring and automatic notification of emerge...
Energy saving refers to the practice of reducing energy consumption in order to decrease energy costs and minimize environmental impact.
Implementing energy-efficient lighting systems
Upgrading to energy-efficient appliances
Using programmable thermostats to regulate heating and cooling
Sealing air leaks in buildings to prevent energy loss
Utilizing renewable energy sources like solar panels
AMC stands for Annual Maintenance Contract, while CAMC stands for Comprehensive Annual Maintenance Contract.
AMC typically covers regular maintenance services for equipment or systems, while CAMC includes both preventive maintenance and repair services.
CAMC is more comprehensive and usually covers a wider range of services compared to AMC.
AMC may have limitations on the scope of services provided, while CAMC offers a mo...
I applied via Naukri.com and was interviewed before Nov 2021. There were 4 interview rounds.
How to manage floor, role and responsibility of executive, team handling
I want to join this organization because of its strong reputation, opportunities for growth, and alignment with my career goals.
The organization has a strong reputation in the industry, which would enhance my professional profile.
There are ample opportunities for growth and advancement within the organization.
The organization's values and mission align with my own career goals and aspirations.
I am impressed by the orga...
I appeared for an interview before Mar 2024.
based on 2 interviews
Interview experience
based on 65 reviews
Rating in categories
Assistant Manager
1.6k
salaries
| ₹3.5 L/yr - ₹10.8 L/yr |
Facility Executive
644
salaries
| ₹2.2 L/yr - ₹6.3 L/yr |
Assistant Facility Manager
517
salaries
| ₹3.5 L/yr - ₹10.2 L/yr |
Facility Manager
503
salaries
| ₹3.8 L/yr - ₹14.3 L/yr |
Deputy Manager
486
salaries
| ₹4 L/yr - ₹13.5 L/yr |
JLL
NoBroker
Cushman & Wakefield
Colliers India