Filter interviews by
I applied via Approached by Company and was interviewed in Oct 2024. There were 3 interview rounds.
Every thing about & your roles & responsibilities etc
SAP MM is a module in SAP ERP that deals with material management and inventory management.
SAP MM stands for SAP Material Management
It involves procurement, inventory management, and invoice verification
It helps in managing materials, vendors, and procurement processes efficiently
OEE stands for Overall Equipment Effectiveness, a measure of how well a manufacturing process is performing.
OEE is calculated by multiplying Availability, Performance, and Quality percentages.
It helps in identifying areas of improvement in production processes.
OEE is often used in lean manufacturing to optimize efficiency.
For example, if a machine has an Availability of 90%, Performance of 80%, and Quality of 95%, the
TPM stands for Total Productive Maintenance, a proactive approach to maintenance that aims to maximize equipment effectiveness.
TPM focuses on preventing equipment breakdowns through regular maintenance and employee involvement
It involves setting up autonomous maintenance teams to perform routine tasks
TPM also includes planned maintenance, quality maintenance, and focused improvement activities
Example: Implementing TPM ...
I applied via Referral
Genus Power Infrastructures interview questions for popular designations
I applied via Approached by Company and was interviewed in Oct 2023. There were 3 interview rounds.
To execute any project successfully, one must plan, organize, execute, monitor, and close the project.
Develop a detailed project plan outlining goals, tasks, timelines, and resources.
Assign roles and responsibilities to team members.
Monitor progress regularly and make adjustments as needed.
Communicate effectively with stakeholders to ensure alignment and manage expectations.
Evaluate project outcomes and lessons learned
Get interview-ready with Top Genus Power Infrastructures Interview Questions
I was interviewed in Mar 2024.
I applied via Recruitment Consulltant and was interviewed in Sep 2023. There were 2 interview rounds.
Implemented lean manufacturing principles resulting in 20% reduction in production costs.
Implemented lean manufacturing principles to streamline production processes
Introduced cost-saving measures such as reducing waste and optimizing resources
Utilized data analysis to identify inefficiencies and implement improvements
Collaborated with cross-functional teams to drive process improvement initiatives
C programming is major required skill
Diodes are electronic components that allow current to flow in one direction only. Common types include PN junction, Schottky, Zener, and light-emitting diodes (LEDs).
PN junction diode: Basic diode that allows current to flow in one direction.
Schottky diode: Faster switching diode with lower voltage drop.
Zener diode: Used for voltage regulation and protection against voltage spikes.
Light-emitting diode (LED): Emits lig...
Rectifiers are electronic devices that convert alternating current (AC) to direct current (DC). Types include half-wave, full-wave, and bridge rectifiers.
Rectifiers are used to convert AC to DC by allowing current to flow in only one direction.
Half-wave rectifiers only allow one half of the AC waveform to pass through, resulting in pulsating DC.
Full-wave rectifiers allow both halves of the AC waveform to pass through, ...
I applied via Walk-in and was interviewed in Apr 2023. There were 3 interview rounds.
Arithmatic and advance
I applied via Company Website and was interviewed in Nov 2022. There were 2 interview rounds.
1 phase energy meter measures power in single phase while 3 phase energy meter measures power in three phases.
1 phase energy meter is used for single phase loads like homes, small offices, etc.
3 phase energy meter is used for three phase loads like industrial motors, large factories, etc.
1 phase energy meter has two wires while 3 phase energy meter has four wires.
1 phase energy meter measures voltage, current, power fa...
Smart meters are advanced energy meters that record energy consumption in real-time and communicate it to the utility company.
Smart meters provide real-time energy consumption data to both the consumer and the utility company.
They can communicate wirelessly or through power lines.
Smart meters can help consumers save money by providing information on energy usage patterns.
They can also help utilities manage energy distr...
CT meter measures current while DT meter measures energy consumption.
CT meter measures the current flowing through a circuit while DT meter measures the energy consumption of a circuit over a period of time.
CT meter is used for protection and control purposes while DT meter is used for billing and energy management purposes.
CT meter is used in high voltage applications while DT meter is used in low voltage applications...
SLD stands for Single Line Diagram, a graphical representation of an electrical system.
It shows the flow of electricity in a system
It includes all the components of the system such as transformers, generators, breakers, etc.
It is used by engineers to design and analyze electrical systems
It is also used for maintenance and troubleshooting purposes
Example: SLD of a power plant or a building's electrical system
Top trending discussions
Some of the top questions asked at the Genus Power Infrastructures interview for experienced candidates -
The duration of Genus Power Infrastructures interview process can vary, but typically it takes about less than 2 weeks to complete.
based on 16 interviews
Interview experience
based on 491 reviews
Rating in categories
Engineer
140
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Engineer
119
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Manager
84
salaries
| ₹0 L/yr - ₹0 L/yr |
Junior Engineer
47
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Engineer
46
salaries
| ₹0 L/yr - ₹0 L/yr |
ABB
Siemens
BHEL
Schneider Electric Infrastructure