Filter interviews by
I applied via Referral and was interviewed in Aug 2023. There was 1 interview round.
Top trending discussions
I applied via campus placement at Birla Institute of Technology and Science (BITS), Pilani and was interviewed in Jul 2024. There were 3 interview rounds.
Social media connecting people
Sfd and bmd diagrams show the variation of shear force and bending moment along the length of a structural member.
SFD (Shear Force Diagram) shows the variation of shear force along the length of a beam or structural member.
BMD (Bending Moment Diagram) shows the variation of bending moment along the length of a beam or structural member.
SFD and BMD are essential for analyzing the internal forces and moments in a structu...
I am a structural engineer with 5 years of experience in designing and analyzing buildings and bridges.
Graduated with a degree in Civil Engineering
Worked on various projects including high-rise buildings and pedestrian bridges
Proficient in software such as AutoCAD and SAP2000
I am open to job locations that offer opportunities for growth and development.
I am willing to relocate for the right job opportunity
I prefer job locations with good transportation options
I am open to both urban and rural locations depending on the job requirements
I applied via Naukri.com and was interviewed in Jun 2024. There were 2 interview rounds.
posted on 25 Nov 2024
I applied via Campus Placement and was interviewed in Oct 2024. There was 1 interview round.
I joined the company because of its innovative projects and collaborative work environment.
Opportunity to work on cutting-edge projects
Collaborative work environment
Company's reputation in the industry
Career growth opportunities
I applied via LinkedIn and was interviewed in Feb 2024. There were 2 interview rounds.
Static analysis deals with loads that do not change over time, while dynamic analysis considers loads that vary with time.
Static analysis is used to determine the effects of loads that do not change over time, such as dead loads and live loads.
Dynamic analysis considers loads that vary with time, such as wind loads, seismic loads, and vibrations.
Static analysis is simpler and less computationally intensive compared to ...
Spectral fatigue analysis is performed by calculating the stress response of a structure to dynamic loads over a range of frequencies.
Determine the dynamic loads acting on the structure
Calculate the stress response of the structure using spectral methods
Analyze the stress response at different frequencies to assess fatigue damage
Consider factors such as material properties, load history, and environmental conditions
Use...
I prioritize transparency, disclose the conflict, and recuse myself if necessary.
Prioritize transparency and disclose the conflict to all parties involved
Evaluate the situation and determine if recusal is necessary
Seek guidance from a supervisor or ethics committee if unsure how to proceed
My notice period is currently one month.
Notice period is one month
I am required to give one month notice before leaving my current position
I can start a new position after one month
Yes, I have extensive experience with basements and below ground structures.
I have designed and analyzed numerous basements for residential and commercial buildings.
I am familiar with waterproofing techniques and soil mechanics related to below ground structures.
I have experience with retaining walls, foundations, and underground parking structures.
I have worked on projects involving deep excavations and shoring system...
I applied via Approached by Company and was interviewed in Apr 2024. There were 2 interview rounds.
Orifice std refers to standard orifice sizes used in engineering. Types of taps include flange taps, corner taps, and D and D/2 taps.
Orifice std refers to standard sizes of orifices used in flow measurement
Types of taps include flange taps, corner taps, and D and D/2 taps
Flange taps are used for large pipes, corner taps for small pipes, and D and D/2 taps for general applications
Pressure gauge operating range refers to the minimum and maximum pressure values that the gauge can accurately measure.
Pressure gauge operating range is typically specified by the manufacturer.
It is important to ensure that the pressure being measured falls within the gauge's operating range to ensure accurate readings.
For example, a pressure gauge with an operating range of 0-100 psi should not be used to measure pres
Straight length requirements for orifice flow element ensure accurate measurement by allowing flow to stabilize before reaching the element.
Straight length requirements typically range from 10 to 44 pipe diameters upstream and 5 to 22 pipe diameters downstream of the orifice.
These requirements help prevent flow disturbances and ensure accurate measurement of flow rate.
For example, if the pipe diameter is 4 inches, the ...
I applied via Referral and was interviewed in Nov 2023. There was 1 interview round.
Pipe wall thickness can be calculated using various methods based on the material, pressure, and temperature of the pipe.
Calculate using Barlow's formula: t = PD/(2S - 0.8P)
Consider factors like material properties, pressure, temperature, and safety factor
Consult relevant codes and standards for specific calculations
Use software tools like CAESAR II for complex piping systems
Lead Engineer
45
salaries
| ₹13 L/yr - ₹25.1 L/yr |
Senior Engineer
41
salaries
| ₹6.9 L/yr - ₹14.5 L/yr |
Senior Design Engineer
25
salaries
| ₹8 L/yr - ₹12.7 L/yr |
Material Analyst
10
salaries
| ₹2.8 L/yr - ₹4 L/yr |
Senior Software Engineer
9
salaries
| ₹6.5 L/yr - ₹14.3 L/yr |
Ford Motor
Hyundai Motor India Engineering
Renault Nissan Technology & Business Centre India
Mahindra & Mahindra