I applied via Referral and was interviewed in Jul 2023. There were 7 interview rounds.
It was tough and lengthy questions
Random topics current affairs normal students
One coding questions to clear the final round
Top trending discussions
posted on 1 Aug 2024
posted on 29 Jun 2024
Manegement Topic of running our company
Current transformer secondary is open to prevent damage to the transformer and connected equipment.
An open secondary circuit prevents excessive current flow and protects the transformer from damage.
It allows for safe measurement and monitoring of current without risk of short circuits.
An open secondary also prevents damage to connected equipment by isolating it from high currents.
In case of a fault or overload, an open...
CT and PT are both electrical devices used in power systems, but they have different functions and applications.
CT stands for Current Transformer, while PT stands for Potential Transformer.
CTs are used to measure and transform high currents into manageable levels for instruments and protective relays.
PTs are used to measure and transform high voltages into low voltages for instruments and protective relays.
CTs are typi...
The single line diagram for HY to LT Panel diagram is a visual representation of the electrical connections and components in the system.
The single line diagram shows the flow of electrical power from the HY (High Voltage) side to the LT (Low Tension) side.
It includes the main components such as transformers, circuit breakers, switches, and control devices.
The diagram also indicates the interconnections between differe...
The number of circuit breakers used in an electrical system varies depending on the size and complexity of the system.
The number of circuit breakers used in an electrical system depends on factors such as the size of the system, the number of circuits, and the specific requirements of the building or facility.
Residential electrical systems typically have a main circuit breaker at the electrical panel, along with indivi...
In a power failure situation, effective management involves ensuring safety, communication, and contingency planning.
Ensure the safety of employees and customers by providing emergency lighting and clear evacuation procedures.
Maintain open lines of communication with staff, customers, and relevant authorities to provide updates and coordinate actions.
Implement contingency plans such as backup power sources, alternative...
B check in a generator refers to a comprehensive inspection and maintenance procedure to ensure its proper functioning.
B check involves a thorough examination of the generator's components, including the engine, fuel system, cooling system, electrical system, and control panel.
It includes tasks such as checking for leaks, inspecting belts and hoses, testing the battery, cleaning or replacing filters, and verifying prop...
I was interviewed in Jul 2023.
posted on 6 Oct 2023
I was interviewed in Sep 2023.
The name of the college is XYZ University.
Located in City, State
Offering programs in Engineering, Business, and Arts
Ranked in top 10 universities in the country
To verify a problem with the test, I would follow a systematic approach.
Review the test procedure and documentation to ensure it was followed correctly
Check the test equipment and instruments for any malfunctions or inaccuracies
Repeat the test using a different sample or control to compare results
Consult with colleagues or experts for their insights and opinions
Perform additional tests or experiments to gather more dat
posted on 27 Apr 2023
I applied via LinkedIn and was interviewed in Mar 2023. There was 1 interview round.
posted on 14 Sep 2023
I applied via campus placement at St. Peters Engineering College, Hyderabad and was interviewed before Sep 2022. There were 4 interview rounds.
Related to all electronics and communication Engineering questions likes analog and digital circuits and aptitude questions
based on 143 reviews
Rating in categories
Installation & Commissioning Engineer
33
salaries
| ₹2.2 L/yr - ₹5 L/yr |
Senior Engineer Marketing
17
salaries
| ₹5.4 L/yr - ₹8.6 L/yr |
Marketing Engineer
14
salaries
| ₹3.3 L/yr - ₹6 L/yr |
Design Engineer
13
salaries
| ₹2 L/yr - ₹4 L/yr |
Electrical Design Engineer
13
salaries
| ₹1.8 L/yr - ₹4.8 L/yr |
Dixon Technologies
Secure Meters
Centum Electronics
Jabil Circuit India