Filter interviews by
I applied via Campus Placement and was interviewed in Apr 2024. There was 1 interview round.
I am a dedicated and experienced Electrical Engineer with a passion for problem-solving and innovation.
Graduated with a degree in Electrical Engineering from XYZ University
Worked at ABC Company for 5 years, specializing in power systems
Proficient in CAD software and PLC programming
Led a team in designing and implementing a new control system for a manufacturing plant
Total loads in a room can be calculated by adding up the power consumption of all devices.
Identify all electrical devices in the room
Determine the power consumption of each device
Add up the power consumption of all devices to get the total load
Various equipment such as oscilloscopes, multimeters, power supplies, and soldering irons are necessary in the industry.
Oscilloscopes for measuring and analyzing electronic signals
Multimeters for measuring voltage, current, and resistance
Power supplies for providing electrical power to circuits
Soldering irons for joining electronic components
I applied via Referral and was interviewed in Sep 2022. There were 2 interview rounds.
Development length is the length of reinforcement required to transfer the stress from steel to concrete.
It is the minimum length of reinforcement bar required to be embedded in concrete to develop its full strength.
It is influenced by the diameter of the bar, the grade of the steel, and the strength of the concrete.
It is calculated based on the bond strength between steel and concrete.
For example, if the development l...
The minimum thickness of an RCC slab depends on various factors such as span, load, and deflection criteria.
The minimum thickness of an RCC slab is typically determined by structural engineers based on the span of the slab.
The thickness also depends on the load that the slab needs to support. Heavier loads require thicker slabs.
Deflection criteria, which refers to the amount of bending or sagging the slab can tolerate,...
The number of cement bags in one cubic metre depends on the density of the cement.
The density of cement varies between 1,200 to 1,800 kg/m³
The weight of one cement bag is usually 50 kg
Therefore, the number of cement bags in one cubic metre ranges from 55 to 83 bags
Density of aggregate is the mass per unit volume of the material.
Density is an important property of aggregates used in construction.
It is measured in kg/m³ or lb/ft³.
The density of different types of aggregates varies depending on their composition.
For example, the density of granite aggregate is around 2.7 g/cm³.
The density of lightweight aggregates like expanded clay or shale is around 1.5 g/cm³.
The nominal size of a concrete cube is 150 mm.
The nominal size of a concrete cube is the length of one side of the cube.
It is used to test the compressive strength of concrete.
The standard size of a concrete cube is 150 mm, but other sizes can also be used.
The cubes are made and cured under controlled conditions before testing.
Weight of 16 mm dia steel in one metre
The weight of 16 mm diameter steel rod per metre can be calculated by using the formula D^2/162
Here, D is the diameter of the steel rod in millimeters
So, the weight of 16 mm diameter steel rod per metre is (16^2)/162 = 1.580 kg/m
The minimum diameter of steel used in a slab depends on the span, load, and thickness of the slab.
The minimum diameter of steel bars used in a slab is usually 8mm.
However, for longer spans and heavier loads, larger diameter bars may be required.
The thickness of the slab also affects the minimum diameter of steel used.
For example, a 100mm thick slab may require 10mm diameter bars.
The minimum diameter of steel used in a
The minimum diameter of steel used in a column depends on the load it needs to bear and the height of the column.
The minimum diameter of steel used in a column is typically 12mm.
However, it can vary depending on the load it needs to bear and the height of the column.
For taller columns, larger diameter steel bars may be required to ensure structural stability.
The diameter of steel used in a column should be specified in...
The ratio of M15 is 1:2:4 (cement:sand:aggregate) for concrete mix.
M15 is a mix of concrete with a compressive strength of 15 N/mm².
The ratio of M15 is commonly used for residential construction.
The ratio of M15 can be adjusted based on the specific requirements of the project.
posted on 29 Jun 2015
posted on 29 Jun 2015
posted on 14 Jul 2017
I appeared for an interview before Jul 2016.
posted on 17 Feb 2021
I applied via Walk-in and was interviewed in Aug 2020. There was 1 interview round.
I applied via Campus Placement and was interviewed before Jan 2020. There were 5 interview rounds.
posted on 23 Oct 2020
I applied via Recruitment Consultant and was interviewed in Apr 2020. There were 3 interview rounds.
I applied via Approached by Company and was interviewed before Apr 2021. There was 1 interview round.
based on 1 interview
Interview experience
based on 5 reviews
Rating in categories
Civil Site Engineer
6
salaries
| ₹3 L/yr - ₹3.6 L/yr |
HSE Officer
4
salaries
| ₹2.5 L/yr - ₹4.4 L/yr |
Senior Engineer
3
salaries
| ₹5.7 L/yr - ₹9.4 L/yr |
Civil Engineer
3
salaries
| ₹3 L/yr - ₹4.2 L/yr |
Billing Engineer
3
salaries
| ₹3 L/yr - ₹5.5 L/yr |
Megha Engineering & Infrastructures
Shapoorji Pallonji Group
Alstom Transportation
Tata Technologies