Filter interviews by
I applied via Walk-in and was interviewed before May 2022.Ā There were 3 interview rounds.
I am a highly organized and detail-oriented project manager with experience in leading cross-functional teams and delivering successful projects.
I have a proven track record of delivering projects on time and within budget
I am skilled in stakeholder management and communication
I am experienced in using project management tools such as Jira and Asana
I am constantly seeking to improve my skills and stay up-to-date with i...
The testing of VRF system piping is done at a pressure of 1.5 times the maximum working pressure.
VRF system piping is tested at 1.5 times the maximum working pressure
This is to ensure the system can handle the maximum pressure it may encounter during operation
I applied via Referral and was interviewed before Jan 2021.Ā There were 4 interview rounds.
HVAC stands for Heating, Ventilation, and Air Conditioning. It refers to the technology used for indoor environmental comfort.
HVAC is a system that controls the temperature, humidity, and air quality in buildings.
It includes components such as furnaces, air conditioners, ventilation systems, and thermostats.
Heating is provided by systems like boilers or electric heaters.
Ventilation ensures fresh air circulation and rem...
To calculate duct manually with help of Ishare, follow these steps:
Determine the airflow rate required for the space
Calculate the friction loss in the duct using the Darcy-Weisbach equation
Select the appropriate duct size based on the airflow rate and friction loss
Use Ishare to calculate the pressure drop across the duct
Adjust the duct size and/or airflow rate as necessary to meet design requirements
Duct sizing with Ductul involves calculating the required airflow and selecting the appropriate duct size.
Calculate the required airflow based on the room size and usage
Determine the friction loss in the duct system
Select the appropriate duct size based on the calculated airflow and friction loss
Consider the material and shape of the duct for optimal performance
Use Ductul software for accurate calculations and sizing
Heat load calculation can be done using Excel sheet E-20
Open Excel sheet E-20
Enter the relevant data such as room dimensions, insulation, and equipment
Use formulas to calculate the heat load
Consider factors such as solar gain and occupancy
Review and adjust calculations as necessary
AutoCAD commands are used to create, edit and manipulate 2D and 3D designs.
LINE - draw a straight line
CIRCLE - draw a circle
RECTANGLE - draw a rectangle
TRIM - trim objects to a specified boundary
EXTEND - extend objects to a specified boundary
MOVE - move objects to a new location
COPY - create a copy of an object
ARRAY - create a pattern of objects
MIRROR - create a mirrored copy of an object
SCALE - resize objects proporti...
Top trending discussions
I applied via Recruitment Consultant and was interviewed in Mar 2021.Ā There were 3 interview rounds.
A framework is a set of guidelines, standards, and tools used to develop software applications.
A framework provides a structure for developers to build upon
It includes pre-written code and libraries to simplify development
Frameworks can be specific to a programming language or platform
Examples include React for web development and TensorFlow for machine learning
I applied via Campus Placement and was interviewed before Nov 2020.Ā There were 4 interview rounds.
posted on 19 Nov 2020
I applied via Campus Placement and was interviewed in Jan 2021.Ā There were 3 interview rounds.
Swap two numbers with and without temporary variable
Without temporary variable: Use addition and subtraction
With temporary variable: Use a third variable to store the value of one of the numbers
Example without temporary variable: a=5, b=7; a=a+b; b=a-b; a=a-b;
Example with temporary variable: a=5, b=7; temp=a; a=b; b=temp;
I applied via Naukri.com and was interviewed in Jan 2020.Ā There were 3 interview rounds.
Depreciation is necessary to allocate the cost of an asset over its useful life.
Depreciation helps in matching the cost of an asset with the revenue it generates.
It allows for the recognition of the wear and tear, obsolescence, and loss of value of assets over time.
Depreciation expense reduces taxable income, resulting in tax savings for companies.
It helps in determining the true profitability and financial position of...
I applied via Naukri.com and was interviewed in Oct 2020.Ā There was 1 interview round.
Second level cache is a caching mechanism used to improve performance by storing frequently accessed data in memory.
Second level cache is implemented at the application level and can be configured using frameworks like Hibernate.
To optimize SQL queries, one can use indexes, avoid using SELECT *, and use JOINs instead of subqueries.
SOLID principles are a set of design principles for writing maintainable and scalable cod...
To deploy an application in AWS, you need to create an EC2 instance, configure security groups, install necessary software, and upload your application code.
Create an EC2 instance in the desired region and select the appropriate instance type
Configure security groups to allow traffic to and from the instance
Install necessary software and dependencies on the instance
Upload your application code to the instance
Start the ...
I applied via Referral and was interviewed before Mar 2021.Ā There was 1 interview round.
based on 1 interview
Interview experience
based on 5 reviews
Rating in categories
Hvac Design Engineer
5
salaries
| ā¹1.8 L/yr - ā¹2.6 L/yr |
Project Engineer Hvac
4
salaries
| ā¹2.2 L/yr - ā¹4.2 L/yr |
Design Engineer
3
salaries
| ā¹1.4 L/yr - ā¹1.8 L/yr |
Hvac Engineer
3
salaries
| ā¹2.5 L/yr - ā¹3 L/yr |