I applied via AngelList and was interviewed in Jan 2024. There were 2 interview rounds.
To convert a plus chiller to a minus chiller package, the refrigeration system needs to be modified to accommodate the change in temperature requirements.
Modify the refrigeration system to allow for lower temperatures
Adjust the settings and controls to operate at negative temperatures
Install additional insulation to maintain lower temperatures
Replace any components that are not rated for sub-zero temperatures
Inverter changes speed based on load, while fixed speed operates at a constant speed.
Inverter adjusts motor speed to match the required load, saving energy and reducing wear and tear.
Fixed speed motors operate at a constant speed regardless of the load, leading to higher energy consumption.
Inverter technology is commonly used in air conditioners and refrigerators for energy efficiency.
Fixed speed motors are often found...
Pump HP is calculated using the formula: HP = (Q x H) / (3960 x Efficiency)
HP = Horsepower of the pump
Q = Flow rate of the pump in gallons per minute (GPM)
H = Total head in feet
Efficiency = Efficiency of the pump as a decimal
Suction head is the vertical distance between the pump impeller and the surface of the liquid being pumped.
Suction head is important in determining the efficiency of a pump.
It is crucial for ensuring that the pump does not cavitate, which can damage the pump.
Examples of suction head include static suction head and dynamic suction head.
Chiller selection is based on various parameters such as cooling capacity, efficiency, size, noise level, and cost.
Cooling capacity: Determine the required cooling capacity based on the size of the space and heat load.
Efficiency: Look for energy-efficient models to reduce operating costs.
Size: Consider the physical dimensions of the chiller to ensure it fits in the designated space.
Noise level: Choose a chiller with lo...
The inlet and outlet temperatures for both the evaporator and condenser depend on the ambient conditions prescribed by ISHRAE.
Inlet and outlet temperatures for the evaporator and condenser will vary based on the ambient conditions specified by ISHRAE standards.
For air-cooled systems, the inlet temperature for the evaporator is typically higher than the outlet temperature, while the opposite is true for the condenser.
IS...
Designing ODU VRF with AHU involves selecting compatible units, determining capacity requirements, and ensuring proper installation.
Select compatible ODU VRF and AHU units based on capacity and efficiency requirements
Calculate the total cooling and heating load of the space to determine the capacity needed
Design the refrigerant piping and electrical connections between the ODU VRF and AHU
Ensure proper ventilation and a...
Refnets are calculated based on the number of referrals made by an individual.
Refnets are typically calculated by counting the number of referrals made by an individual.
The formula for calculating refnets may vary depending on the specific program or system being used.
Refnets can be used to track the effectiveness of referral programs and the performance of individuals in generating referrals.
PIBCV valves are typically installed on the supply side of the chilled water system.
PIBCV valves are installed on the supply side to control the flow of chilled water into the system.
They are often located near the chillers or air handling units.
PIBCV valves help regulate the temperature of the chilled water circulating in the system.
These valves are crucial for maintaining the efficiency and performance of the chilled
IK/TR stands for Installment Key/Total Receivables and NPLV stands for Net Present Loan Value.
IK/TR is a financial metric used to calculate the ratio of total installment payments to total receivables.
NPLV is a financial metric used to determine the net present value of a loan.
IK/TR is important for assessing the repayment capacity of borrowers, while NPLV helps in evaluating the profitability of loans.
Example: If a bo...
The MaX COP of VRF systems is typically higher than that of chillers.
VRF systems generally have a higher COP (Coefficient of Performance) compared to chillers.
VRF systems can achieve COP values of 4 or higher, while chillers typically have COP values around 2 to 3.
The higher COP of VRF systems makes them more energy efficient and cost-effective in the long run.
I applied via LinkedIn and was interviewed in Jan 2022. There were 2 interview rounds.
Grouting is the process of filling gaps or spaces between tiles or masonry with a cement-based material.
Grouting helps to create a uniform and stable surface.
It prevents water from seeping through gaps and causing damage.
Grouting can be done with different types of materials such as cement, epoxy, or urethane.
The process involves mixing the grout material with water to form a paste, applying it to the gaps, and then wi...
Voltas interview questions for designations
Get interview-ready with Top Voltas Interview Questions
Top trending discussions
posted on 9 Dec 2024
I applied via Approached by Company
Compressors in VCRs are used to compress the refrigerant gas, increasing its pressure and temperature for efficient heat transfer.
Compressors help in maintaining the desired temperature inside the VCR by compressing the refrigerant gas.
They increase the pressure and temperature of the refrigerant gas, making it easier to transfer heat.
Compressors play a crucial role in the cooling process of VCRs by circulating the ref...
I applied via Recruitment Consulltant and was interviewed in Dec 2022. There were 6 interview rounds.
I have 8 years of experience in HVAC sales.
8 years of experience in HVAC sales
Managed a team of sales representatives
Successfully increased sales by 20% in the last year
My total Sales Target is 50 Lakhs with 100 ODU. I handle products like electronics, home appliances, and furniture.
Total Sales Target: 50 Lakhs
Number of ODU: 100
Products handled: electronics, home appliances, furniture
Yes, I am aware of how to do heat load and BOQ preparation.
For heat load calculation, I consider factors like building size, insulation, number of occupants, and equipment usage.
For BOQ preparation, I consider materials needed, quantities required, labor costs, and any additional expenses.
I also take into account any special requirements or specifications provided by the client or project manager.
Examples: For heat loa...
I have handled territories in the Midwest region, major dealers include ABC Company and XYZ Inc., and have contributed to a 20% increase in business.
Handled territories in the Midwest region
Major dealers include ABC Company and XYZ Inc.
Contributed to a 20% increase in business
2 Hours -logical ,Apti & case based questions.
My in hand salary is the amount I receive after deductions. The fixed component of my CTC is the guaranteed portion of my salary, while the variable component depends on performance.
In hand salary is the amount received after deductions such as taxes and other withholdings.
Fixed component of CTC is the guaranteed portion of salary, such as base salary.
Variable component of CTC is the portion that can vary based on perf
My expected CTC is negotiable based on the responsibilities and benefits offered for the Assistant Manager position.
My expected CTC is based on industry standards and my level of experience.
I am open to discussing the salary range during the interview process.
I am looking for a competitive salary package that reflects my skills and contributions to the role.
1 Interview rounds
based on 88 reviews
Rating in categories
Assistant Manager
467
salaries
| ₹4 L/yr - ₹16.6 L/yr |
Service Engineer
214
salaries
| ₹1.8 L/yr - ₹9 L/yr |
AC Technician
190
salaries
| ₹0.4 L/yr - ₹6.1 L/yr |
Safety Officer
156
salaries
| ₹2.8 L/yr - ₹7 L/yr |
Senior Engineer
146
salaries
| ₹3.5 L/yr - ₹9.2 L/yr |
Blue Star
Thermax Limited
Kirloskar Brothers
Johnson Controls Hitachi Air Conditioning