Transformer vector group is a method used to represent the phase shift between the primary and secondary windings of a transformer.
Transformer vector group indicates the relationship between the primary and secondary winding phases.
It helps in determining the connection and phase shift of the transformer windings.
Common vector groups include Yy0, Yd1, Dyn11, etc.
Vector group is important for parallel operation of trans
VBD test is conducted in transformers to ensure insulation integrity and detect any potential faults.
VBD test helps in identifying any weak spots in the insulation of the transformer
It helps in preventing breakdowns and ensuring the safety and reliability of the transformer
By conducting VBD test, any potential faults can be detected early and necessary maintenance can be carried out
It is a standard procedure in transfo
I applied via Walk-in and was interviewed in Jul 2023. There were 3 interview rounds.
I was interviewed in Aug 2023.
I applied via Naukri.com
I applied via Walk-in and was interviewed in Mar 2022. There were 2 interview rounds.
posted on 28 Dec 2024
posted on 1 Apr 2023
I applied via Walk-in and was interviewed in Mar 2023. There were 2 interview rounds.
posted on 28 May 2023
I applied via Referral and was interviewed before May 2022. There were 2 interview rounds.
AHU stands for Air Handling Unit.
AHU is a device used to regulate and circulate air as part of a heating, ventilation, and air conditioning (HVAC) system.
It typically consists of a blower, heating or cooling elements, filters, dampers, and sound attenuators.
AHUs are commonly found in commercial and industrial buildings to maintain indoor air quality and comfort.
Examples of AHU manufacturers include Trane, Carrier, and
Air Handling Unit
AHU stands for Air Handling Unit
AHUs are used to regulate and circulate air as part of HVAC systems
They typically consist of a blower, heating or cooling elements, filters, and dampers
AHUs are commonly found in commercial and industrial buildings
posted on 10 Oct 2024
I applied via Referral and was interviewed in Sep 2024. There was 1 interview round.
Transformer vector group is a method used to represent the phase shift between the primary and secondary windings of a transformer.
Transformer vector group indicates the relationship between the primary and secondary winding phases.
It helps in determining the connection and phase shift of the transformer windings.
Common vector groups include Yy0, Yd1, Dyn11, etc.
Vector group is important for parallel operation of trans
VBD test is conducted in transformers to ensure insulation integrity and detect any potential faults.
VBD test helps in identifying any weak spots in the insulation of the transformer
It helps in preventing breakdowns and ensuring the safety and reliability of the transformer
By conducting VBD test, any potential faults can be detected early and necessary maintenance can be carried out
It is a standard procedure in transfo
Interview experience
based on 8 reviews
Rating in categories
Facility Manager
69
salaries
| ₹3.1 L/yr - ₹9.3 L/yr |
Facility Executive
46
salaries
| ₹2.2 L/yr - ₹4.8 L/yr |
Supervisor
37
salaries
| ₹1.4 L/yr - ₹4.5 L/yr |
Electrical Engineer
34
salaries
| ₹2.2 L/yr - ₹6.3 L/yr |
Electrical Maintenance Engineer
33
salaries
| ₹1.2 L/yr - ₹5 L/yr |
Urban Company
Housejoy
Qube Services
Timesaverz