Filter interviews by
I applied via Walk-in and was interviewed in Sep 2023. There were 2 interview rounds.
Slump test is a concrete test to measure the consistency and workability of freshly mixed concrete.
It involves filling a slump cone with concrete, then removing the cone and measuring how much the concrete slumps or settles.
The amount of slump can indicate the water content, mix proportions, and consistency of the concrete.
A higher slump value indicates a more workable mix, while a lower slump value indicates a stiffer...
Concrete mix design involves determining the proportions of ingredients to achieve desired properties.
Concrete mix design is the process of selecting suitable ingredients and determining their proportions to produce concrete with desired properties.
Factors to consider in mix design include strength, workability, durability, and cost.
Examples of ingredients in concrete mix design are cement, water, aggregates, and admix
Pile foundation is a type of deep foundation used to transfer loads from a structure to a stronger layer of soil or rock deep below the surface.
Pile foundations are used when shallow foundations are not feasible due to weak soil conditions or high structural loads.
There are different types of pile foundations, including driven piles, bored piles, and screw piles.
Pile foundations can be made of materials such as concret...
TCE interview questions for designations
I applied via Approached by Company and was interviewed in Oct 2022. There were 3 interview rounds.
Technical questions about Construction engineering..
Get interview-ready with Top TCE Interview Questions
I applied via Approached by Company and was interviewed before Mar 2023. There was 1 interview round.
I applied via Walk-in and was interviewed before Oct 2022. There were 4 interview rounds.
I applied via Company Website and was interviewed in Jun 2022. There were 3 interview rounds.
I applied via Referral and was interviewed in Feb 2022. There were 2 interview rounds.
The height of Piperack tier 1 depends on various factors such as the size of the pipes and the distance between them.
The height of Piperack tier 1 can range from 3 to 6 meters.
The height is determined by the size of the pipes and the distance between them.
The height also depends on the weight of the pipes and the load they can bear.
The height may vary based on the location and the purpose of the Piperack.
Consulting the...
Codes and standards are guidelines and regulations that ensure safety, quality, and consistency in various industries.
Codes and standards are developed by industry organizations, government agencies, and professional associations.
They cover a wide range of topics such as building codes, electrical codes, safety standards, and environmental regulations.
Compliance with codes and standards is often mandatory and failure t...
A pile is a long, cylindrical structure made of materials such as concrete, steel, or wood, used to support heavy loads.
Piles are commonly used in construction to support buildings, bridges, and other structures.
They are driven or drilled into the ground to provide stability and prevent settling or shifting.
Different types of piles include timber, concrete, steel, and composite piles.
Pile foundations are often used in ...
Vertical load test of pile is a test to determine the load carrying capacity of a pile.
A vertical load is applied to the pile using a hydraulic jack or a reaction frame.
The load is increased until the pile reaches its ultimate capacity or a predetermined limit.
The test helps in determining the pile's load settlement behavior and its ultimate bearing capacity.
The test is commonly used in the construction industry to ens...
Lateral load test of pile is a test to determine the lateral capacity of a pile.
It involves applying a horizontal load to the pile and measuring the deflection.
The test is conducted by using a hydraulic jack or a reaction frame.
The lateral load test helps in determining the lateral load capacity of the pile.
The test results are used to design the foundation of the structure.
The lateral load test is important for struct...
Yes
Yes, there is an IS code for vertical load test of piles.
The relevant IS code is IS 2911 (Part 4): 2013 - 'Design and construction of pile foundations - Load test on piles'.
This code provides guidelines for conducting vertical load tests on piles to determine their load-carrying capacity and performance.
The code covers various aspects such as test setup, instrumentation, loading procedures, acceptance criteria, and ...
Vertical load test of pile is done to determine the load carrying capacity of the pile.
To ensure the pile can support the intended load
To determine the settlement of the pile under load
To verify the design assumptions
To assess the quality of the pile installation
Examples: bridge piers, high-rise buildings, transmission towers
Vertical load test is a procedure to determine the load-bearing capacity of a structure.
The test involves applying a vertical load to the structure and measuring the resulting deflection.
The load is gradually increased until the structure reaches its maximum load-bearing capacity.
The test can be performed using hydraulic jacks, weights, or other equipment.
The results of the test are used to ensure the safety and stabil...
Lateral load test is a procedure to determine the strength and stability of a structure against horizontal forces.
The test involves applying a horizontal force to the structure and measuring its response.
The force is usually applied using hydraulic jacks or a reaction frame.
The test is performed on a representative section of the structure, such as a column or a wall.
The results of the test are used to verify the desig...
SPT test is a standard penetration test used to determine the soil's resistance to penetration.
SPT test involves driving a standard sampler into the soil using a hammer of standard weight and height.
The number of blows required to drive the sampler a certain distance is recorded as the SPT N-value.
SPT test is commonly used in geotechnical engineering to determine soil properties such as shear strength and bearing capac...
MPR, WPR, and DPR are acronyms used in various fields to represent different concepts.
MPR stands for Monthly Progress Report, which is a document that provides an overview of the progress made during a specific month.
WPR stands for Weekly Progress Report, which is a document that highlights the progress made on a weekly basis.
DPR stands for Daily Progress Report, which is a document that summarizes the daily progress m...
BBS calculation is a method used to determine the reinforcement required for a pile.
BBS stands for Bar Bending Schedule.
It involves calculating the length and number of steel bars required for the pile.
Factors such as load capacity, soil type, and pile diameter are taken into consideration.
The BBS is used to ensure the pile can withstand the required load and prevent failure.
The number of tests required for a pile depends on various factors such as the type of pile, soil conditions, and project requirements.
The number of tests can range from one to several depending on the project.
Common tests for piles include static load tests, dynamic load tests, and integrity tests.
Factors such as pile length, diameter, and soil type can affect the number of tests required.
The project specifications an...
The cut off level of pile depends on various factors such as soil type, load capacity, and design requirements.
The cut off level of pile is the depth at which the pile is embedded into the ground.
It is determined by the soil type and load capacity of the ground.
The design requirements of the structure being built also play a role in determining the cut off level of pile.
For example, if the structure requires a deeper f...
The minimum distance of detume bar of pile vertical load test is typically 2.5 times the diameter of the pile.
The detume bar is used to measure the settlement of the pile during the load test.
The minimum distance is important to ensure accurate measurement of the pile settlement.
The distance is typically 2.5 times the diameter of the pile, but may vary depending on the specific test requirements.
If the distance is too ...
Dynamic load test of pile is done to assess its load carrying capacity and integrity.
To ensure the pile can withstand the expected load and prevent failure
To determine the pile's ultimate bearing capacity
To assess the pile's integrity and detect any defects or damage
To verify the design assumptions and optimize the foundation design
Examples: bridge piers, tall buildings, wind turbines, etc.
Integrity test of pile is done to ensure the pile is structurally sound and can bear the required load.
To ensure the pile is not damaged during installation
To check if the pile is free from any defects or cracks
To verify if the pile can bear the required load
To ensure the safety of the structure and its occupants
Examples: Sonic Integrity Testing, Crosshole Sonic Logging, etc.
Top trending discussions
based on 71 reviews
Rating in categories
Assistant Manager
517
salaries
| ₹4.5 L/yr - ₹13 L/yr |
Manager
330
salaries
| ₹6.2 L/yr - ₹16.1 L/yr |
Senior Manager
318
salaries
| ₹10 L/yr - ₹22.2 L/yr |
Senior Engineer
317
salaries
| ₹3.6 L/yr - ₹10 L/yr |
Consultant
194
salaries
| ₹3.9 L/yr - ₹15.3 L/yr |
Infosys
Wipro
HCLTech
Tech Mahindra