I applied via Approached by Company and was interviewed before Jun 2020. There were 2 interview rounds.
Power factor correction methods, load flow analysis, and different types of transformer tests are important topics in operations management.
Power factor correction methods are used to improve the power factor of electrical systems, which helps in reducing energy losses and improving efficiency.
Load flow analysis is a technique used to study the flow of power in an electrical network, helping in determining voltage leve...
Top trending discussions
I appeared for an interview in Sep 2020.
I applied via Approached by Company and was interviewed in Dec 2023. There were 2 interview rounds.
Channel sales refers to the process of selling products through third-party distributors or partners rather than directly to the end customers.
Involves using intermediaries such as wholesalers, retailers, or value-added resellers to reach customers
Allows companies to expand their reach and access new markets
Requires effective communication and collaboration with channel partners
Examples include selling software through...
Solar on grid system is a type of solar power system that is connected to the main electricity grid.
Solar panels generate electricity from sunlight
Excess electricity can be fed back into the grid
Reduces dependency on traditional power sources
Commonly used in residential and commercial buildings
posted on 29 Aug 2023
I applied via Naukri.com and was interviewed before Aug 2022. There were 5 interview rounds.
There is general aptitude test.
I applied via Referral and was interviewed in Sep 2023. There was 1 interview round.
I appeared for an interview before Jan 2024.
Tests conducted on power transformers include insulation resistance test, turns ratio test, and power factor test.
Insulation resistance test checks the insulation of the transformer windings.
Turns ratio test verifies the turns ratio between primary and secondary windings.
Power factor test measures the efficiency of the transformer in converting power.
Other tests include winding resistance test, transformer oil testing,
Specifications for a 33 kV transmission line and how to select appropriate specifications
Specifications for a 33 kV transmission line include conductor size, insulation type, tower height, and distance between towers
Conductor size should be chosen based on current carrying capacity and voltage drop considerations
Insulation type should be selected based on environmental conditions and required insulation levels
Tower hei...
As an Assistant Manager, my job profile involves assisting the manager in overseeing daily operations, managing staff, and ensuring customer satisfaction.
Assist manager in daily operations
Manage staff and delegate tasks
Ensure customer satisfaction and handle customer complaints
Create work schedules and monitor employee performance
Relay coordination in electrical systems is the process of ensuring that protective relays operate in a coordinated manner to isolate faults while minimizing disruption to the system.
Relay coordination involves setting time-current curves for protective relays to ensure that the relay closest to the fault operates first.
It is important to coordinate relays to prevent unnecessary tripping of healthy equipment during a f...
I applied via LinkedIn and was interviewed before Mar 2023. There was 1 interview round.
I applied via Approached by Company and was interviewed before Oct 2023. There was 1 interview round.
Currently working as a Sales Manager at XYZ Company
Responsible for leading a team of sales representatives
Developing sales strategies to meet targets
Analyzing sales data and trends
Building relationships with clients and vendors
posted on 24 Jul 2023
I applied via Approached by Company and was interviewed in Jun 2023. There were 3 interview rounds.
Testing of equipments involves ensuring they are functioning properly and meet safety standards.
Regularly inspect equipment for any signs of damage or wear
Conduct performance tests to ensure equipment is functioning as expected
Calibrate equipment regularly to maintain accuracy
Follow manufacturer's guidelines for testing and maintenance
Keep detailed records of testing and maintenance activities
Train staff on proper use ...
based on 1 review
Rating in categories
Assistant Manager
231
salaries
| ₹5.6 L/yr - ₹15.6 L/yr |
Manager
149
salaries
| ₹7 L/yr - ₹18 L/yr |
Senior Executive
147
salaries
| ₹4.8 L/yr - ₹16 L/yr |
Officer
100
salaries
| ₹3.8 L/yr - ₹7 L/yr |
Assistant Officer
92
salaries
| ₹3 L/yr - ₹6 L/yr |
Adani Power
ReNew
Adani Green Energy
Vestas