i
Tata Power Delhi Distribution
Filter interviews by
I applied via Company Website and was interviewed in May 2020. There were 6 interview rounds.
Power factor improvement methods involve various techniques to reduce reactive power and improve the efficiency of electrical systems.
Installing power factor correction capacitors
Using synchronous condensers
Applying static VAR compensators
Implementing phase advancers
Utilizing active power filters
Employing harmonic filters
Optimizing motor and equipment sizing
Educating users on power factor awareness and management
The type of distribution network preferred depends on the product and target market.
Direct distribution is preferred for high-end products with a niche market.
Indirect distribution is preferred for mass-market products with a wide target audience.
Hybrid distribution is a combination of both direct and indirect distribution.
Factors such as cost, control, and customer reach should be considered when choosing a distributi
Phase advancer devices are used to improve the power factor of induction motors.
Phase advancer devices are used in induction motors to improve their power factor.
They work by creating a magnetic field that leads the rotor magnetic field, which helps to increase the motor's efficiency.
Examples of phase advancer devices include capacitors, resistors, and inductors.
They are commonly used in industrial settings to improve ...
A ring main unit is a type of switchgear used in power distribution networks.
It is used to control and protect electrical power systems.
It is typically used in medium voltage applications.
It consists of a ring of switches and fuses that can be used to isolate different sections of the network.
It is commonly used in industrial and commercial settings.
Examples of ring main unit manufacturers include ABB, Siemens, and Sch
Reducing losses in distribution network can be achieved through proper maintenance, upgrades, and monitoring.
Regular maintenance of equipment and infrastructure
Upgrading to more efficient technology
Monitoring for leaks and other issues
Implementing smart grid technology
Training staff on best practices
Improving communication and coordination between departments
Investing in renewable energy sources
Using data analytics to
Top trending discussions
I applied via Recruitment Consultant and was interviewed before Sep 2019. There was 1 interview round.
Implement access control, surveillance systems, and security policies to minimize security personnel.
Install access control systems to restrict unauthorized entry
Deploy surveillance systems to monitor activities
Implement security policies to ensure compliance
Train employees on security awareness and emergency response
Conduct regular security audits to identify vulnerabilities
Effective material management in a factory involves proper planning, procurement, storage, and distribution of materials.
Develop a comprehensive material management plan
Ensure timely procurement of raw materials
Implement an efficient storage system
Establish a streamlined distribution process
Regularly monitor inventory levels and adjust accordingly
Returnable and non-returnable stores require different management strategies.
Returnable stores require a system for tracking returned items and restocking them appropriately.
Non-returnable stores require careful inventory management to avoid overstocking and waste.
Consider offering incentives for customers to return items, such as discounts on future purchases.
Train staff on proper handling and processing of returns.
Re...
During a strike against the factory, managing requires effective communication, contingency planning, and prioritizing employee safety.
Communicate regularly with employees to keep them informed and address concerns
Develop contingency plans to minimize disruption to operations and customer service
Prioritize employee safety and well-being, including providing security measures if necessary
Consider negotiating with the st...
To manage and control theft, philferage, vandalism and stobages, one can implement security measures and conduct regular inspections.
Implement security measures such as CCTV cameras, security guards, and access control systems.
Conduct regular inspections to identify any potential security breaches and take necessary actions.
Train employees on security protocols and encourage them to report any suspicious activity.
Maint...
There are 5 classes of fire and each requires a specific type of extinguisher.
Class A fires involve ordinary combustibles like wood, paper, and cloth. Water or foam extinguishers are used.
Class B fires involve flammable liquids like gasoline and oil. Carbon dioxide or dry chemical extinguishers are used.
Class C fires involve electrical equipment. Carbon dioxide or dry chemical extinguishers are used.
Class D fires invol...
PASS procedures are used during firefighting to ensure safety of firefighters.
PASS stands for Pull, Aim, Squeeze, Sweep.
Pull the pin to activate the extinguisher.
Aim the nozzle at the base of the fire.
Squeeze the handle to release the extinguishing agent.
Sweep the nozzle from side to side to cover the area of the fire.
PASS is also used as a distress signal if a firefighter becomes trapped or lost.
The firefighter activa...
Yes, behaviour based safety involves identifying and addressing unsafe behaviours to prevent accidents.
Encourage employees to report unsafe behaviours
Provide training on safe behaviours and consequences of unsafe behaviours
Implement a reward system for safe behaviours
Conduct regular safety audits to identify areas for improvement
Examples: wearing PPE, following proper lifting techniques, reporting near misses
I applied via Company Website and was interviewed in Oct 2022. There were 3 interview rounds.
I applied via Naukri.com and was interviewed before Mar 2023. There was 1 interview round.
The DCS architecture of our plant is a distributed control system with a hierarchical structure. The governing system is a combination of PLCs and SCADA.
Our DCS is based on a distributed control system architecture
It has a hierarchical structure with multiple levels of control
The governing system is a combination of PLCs and SCADA
The PLCs are responsible for controlling the individual processes
The SCADA system provides...
Flame scanner detects flame by analyzing the light emitted by the flame.
Flame scanner uses a photodetector to measure the intensity of light emitted by the flame.
The photodetector sends a signal to the controller which analyzes the signal to determine if there is a flame or not.
The controller compares the signal to a pre-set threshold to determine if the light intensity is high enough to indicate a flame.
If the signal ...
I applied via Naukri.com and was interviewed in May 2024. There were 2 interview rounds.
General Technical with awareness about domain
I applied via Referral and was interviewed in Feb 2023. There were 2 interview rounds.
Selection priority refers to the criteria or factors used to determine the order in which candidates are chosen for a position.
Selection priority is based on the qualifications, skills, and experience of the candidates.
It may also consider factors such as cultural fit, leadership potential, and alignment with company values.
The selection priority can vary depending on the specific needs and goals of the organization.
Fo...
I usually ask the referring person how they know the candidate.
I ask for the name of the person who referred them
I ask how they know the person
I may ask for more information about their relationship or work experience
I verify the referral by contacting the person who referred them
I applied via Referral and was interviewed before Nov 2023. There was 1 interview round.
I appeared for an interview in Feb 2023.
based on 23 reviews
Rating in categories
Assistant Manager
231
salaries
| ₹5.6 L/yr - ₹15.6 L/yr |
Manager
149
salaries
| ₹7 L/yr - ₹18 L/yr |
Senior Executive
148
salaries
| ₹4.7 L/yr - ₹16 L/yr |
Officer
102
salaries
| ₹3.8 L/yr - ₹7 L/yr |
Assistant Officer
89
salaries
| ₹3.2 L/yr - ₹6 L/yr |
Adani Power
ReNew
Adani Green Energy
Vestas