Closed loop control systems are feedback systems that continuously monitor and adjust the output based on the desired input.
Closed loop control systems use feedback to maintain a desired output
They continuously monitor the output and compare it to the desired input
Based on the comparison, adjustments are made to maintain the desired output
Examples include thermostat-controlled heating systems and cruise control in cars
I applied via Job Portal and was interviewed before Apr 2023. There were 2 interview rounds.
I applied via Campus Placement and was interviewed before Jun 2021. There were 4 interview rounds.
Discussion on execution of work strategy.
Efficiency of a boiler can be increased by improving insulation, optimizing combustion, and regular maintenance.
Improve insulation to reduce heat loss
Optimize combustion by adjusting air-to-fuel ratio and using efficient burners
Regular maintenance to clean and repair components
Use economizers to recover waste heat
Upgrade to high-efficiency boilers
Implement energy management systems to monitor and control boiler operati
I have worked on various DCS architectures in my career, including those for chemical plants and power plants.
Designed and implemented DCS architecture for a chemical plant project
Developed DCS architecture for a power plant project
Worked on DCS architecture for a water treatment plant project
Collaborated with team to create DCS architecture for a pharmaceutical plant project
Profibus is a widely used fieldbus communication protocol in industrial automation.
Profibus stands for Process Field Bus.
It is used for communication between field devices and control systems in industrial automation.
There are two main types of Profibus: Profibus DP (Decentralized Peripherals) and Profibus PA (Process Automation).
Profibus uses a master-slave communication model.
It is known for its high-speed data trans...
Troubleshooting Profibus involves checking physical connections, network configuration, and device settings.
Check physical connections to ensure cables are properly connected and not damaged.
Verify network configuration settings such as baud rate, parity, and address assignments.
Inspect device settings to ensure they match the network configuration and are functioning correctly.
Use diagnostic tools like Profibus analyz...
based on 1 interview
Interview experience
Chief Manager
163
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Manager
154
salaries
| ₹0 L/yr - ₹0 L/yr |
Manager
112
salaries
| ₹0 L/yr - ₹0 L/yr |
Safety Officer
62
salaries
| ₹0 L/yr - ₹0 L/yr |
Quality Engineer
43
salaries
| ₹0 L/yr - ₹0 L/yr |
Power Grid Corporation of India
Adani Transmission
Tata Power
NHPC