Filter interviews by
The least count of a Micro Meter is 0.01 mm and the least count of a Vernier Caliper is 0.02 mm.
Least count of Micro Meter: 0.01 mm
Least count of Vernier Caliper: 0.02 mm
I applied via Walk-in and was interviewed before Oct 2023. There was 1 interview round.
The least count of a vernier scale is the smallest measurement that can be read on the scale.
The least count is determined by the number of divisions on the main scale and the vernier scale.
It is calculated as the difference between one smallest division on the main scale and one division on the vernier scale.
For example, if the main scale has divisions of 1 mm and the vernier scale has 10 divisions that cover 9 main s
I applied via Walk-in and was interviewed in Jun 2022. There were 2 interview rounds.
The least count of Vernier Caliper is the smallest measurement that can be read on the scale.
The least count of a Vernier Caliper is typically 0.02 mm or 0.001 inches.
It is determined by the number of divisions on the main scale and the Vernier scale.
For example, if the main scale has 20 divisions and the Vernier scale has 18 divisions, the least count would be 0.02 mm.
I applied via Walk-in and was interviewed before Feb 2022. There were 2 interview rounds.
Yes, I am familiar with and have experience using measuring instruments like Bore Gauge, Height Gauge, Micrometer, Vernier Caliper, and PPG.
I have used these instruments extensively in my previous roles as a Quality Engineer
I am familiar with the proper calibration and maintenance of these instruments
I understand the importance of accurate measurements in ensuring product quality
Examples of how I have used these instru...
Yes, I have studied Mechanical Drawing.
I have taken courses in Mechanical Drawing during my engineering studies.
I am proficient in reading and interpreting technical drawings.
I have experience using CAD software to create and modify mechanical drawings.
I understand the importance of accurate and detailed drawings in ensuring quality in manufacturing processes.
8D and CAPA are problem-solving methodologies used in quality management.
8D stands for 8 Disciplines and is used to identify, correct and prevent problems
CAPA stands for Corrective and Preventive Action and is used to identify and eliminate the root cause of a problem
Both methodologies involve a structured approach to problem-solving and require documentation of the process and results
They are commonly used in industri...
Shree Nath Engineering Works interview questions for popular designations
I applied via Walk-in and was interviewed before May 2022. There were 2 interview rounds.
The least count of micrometer is 0.01 mm or 0.001 cm.
Least count is the smallest measurement that can be read on a measuring instrument.
Micrometer is used to measure small distances with high accuracy.
The least count of a micrometer depends on the number of divisions on the thimble and the pitch of the screw.
For example, if the thimble has 50 divisions and the pitch of the screw is 0.5 mm, then the least count would be
GD&T stands for Geometric Dimensioning and Tolerancing. It is a system used to define and communicate engineering tolerances.
GD&T is a language used to communicate design intent and engineering tolerances
It uses symbols, such as concentricity, perpendicularity, and flatness, to specify the allowable variation in a part's geometry
GD&T is used in industries such as aerospace, automotive, and manufacturing
It helps ensure ...
Get interview-ready with Top Shree Nath Engineering Works Interview Questions
Top trending discussions
I applied via Naukri.com and was interviewed in Dec 2020. There was 1 interview round.
QMS stands for Quality Management System. It is a set of policies, processes, and procedures required for planning and execution of quality control.
QMS ensures that products or services meet customer requirements and comply with regulations
It includes quality planning, quality control, quality assurance, and quality improvement
ISO 9001 is a widely recognized QMS standard
QMS is important for industries such as healthcar
To reduce rejections and reworks, implement a robust quality control system and focus on continuous improvement.
Implement a quality control system to catch defects early
Train employees on proper procedures and techniques
Conduct regular audits to identify areas for improvement
Analyze root causes of rejections and reworks to prevent future occurrences
Collaborate with suppliers to improve incoming materials quality
Utilize...
The return type of web elements is usually a string.
Web elements typically return a string value.
Examples of web elements include text boxes, buttons, and links.
The string value returned by a web element can be used for various purposes, such as verification or input manipulation.
I appeared for an interview in Jan 2025.
Studying for a Bachelor of Engineering in Mechanical Engineering has provided me with technical knowledge in various areas.
Solid mechanics and materials science
Thermodynamics and heat transfer
Fluid mechanics and aerodynamics
Mechanical design and analysis
Manufacturing processes and automation
based on 5 interviews
Interview experience
based on 1 review
Rating in categories
Quality Engineer
5
salaries
| ₹1.8 L/yr - ₹1.8 L/yr |
Quaity Control Engineer
4
salaries
| ₹1.8 L/yr - ₹2.2 L/yr |
Quality Controller
3
salaries
| ₹1.4 L/yr - ₹1.8 L/yr |
Refrigeration Technician
3
salaries
| ₹4.8 L/yr - ₹6 L/yr |
TCS
Accenture
Wipro
Cognizant