Filter interviews by
I applied via Naukri.com and was interviewed in Feb 2022. There were 2 interview rounds.
Top trending discussions
I applied via Recruitment Consultant and was interviewed before Apr 2020. There were 3 interview rounds.
4M, 5S, APQP, PPAP, and Quality Circle are all quality management tools used in manufacturing.
4M stands for Man, Machine, Material, and Method and is used to identify the root cause of a problem.
5S is a workplace organization method that stands for Sort, Set in Order, Shine, Standardize, and Sustain.
APQP stands for Advanced Product Quality Planning and is a framework used to ensure quality in new product development.
PP...
I applied via Recruitment Consulltant and was interviewed before Jan 2022. There were 2 interview rounds.
I applied via Naukri.com and was interviewed in Jun 2021. There were 5 interview rounds.
I applied via Recruitment Consultant and was interviewed in Aug 2021. There were 3 interview rounds.
I applied via Company Website and was interviewed before Oct 2020. There were 4 interview rounds.
SFD & BMD for a simply supported load
SFD is a diagram that shows the variation of shear force along the length of a beam
BMD is a diagram that shows the variation of bending moment along the length of a beam
For a simply supported load, the SFD will be a straight line with a constant slope
The BMD will be a parabolic curve with the maximum value at the center of the beam
The SFD and BMD can be calculated using equations an
posted on 2 Feb 2022
I applied via Walk-in and was interviewed before Feb 2021. There were 2 interview rounds.
I applied via Company Website and was interviewed before May 2021. There was 1 interview round.
Impedance is the measure of opposition to the flow of electric current in a circuit. DGR fundamental refers to the Dielectric Withstand Voltage test.
Impedance is measured in ohms and is the combination of resistance, capacitance, and inductance in a circuit.
DGR fundamental is a test to determine the maximum voltage a material can withstand without breaking down.
Basics of impedance include understanding the relationship...
I applied via Naukri.com and was interviewed in Jan 2021. There were 3 interview rounds.
Precommissioning tests of transformers ensure proper functioning and safety before energizing.
Visual inspection of transformer and its components
Measurement of insulation resistance
Measurement of winding resistance
Verification of transformer ratio and polarity
Verification of oil level and quality
Testing of protective devices
Verification of grounding
Functional testing of cooling system
Verification of nameplate data
11kv & 33kv overhead power line distribution
11kv and 33kv are common voltage levels for overhead power lines
Overhead power lines are used to distribute electricity from power stations to consumers
The voltage level determines the distance the power can be transmitted and the size of the conductors needed
Proper insulation and grounding is important for safety
Maintenance and inspection of the lines is necessary to ensure
Assistant Manager
69
salaries
| ₹4.8 L/yr - ₹10 L/yr |
Assistant Engineer
25
salaries
| ₹1.9 L/yr - ₹3.7 L/yr |
Sales Coordinator
21
salaries
| ₹2.7 L/yr - ₹5.5 L/yr |
Senior Engineer
18
salaries
| ₹4.5 L/yr - ₹6 L/yr |
Assistant Sales Manager
17
salaries
| ₹5.6 L/yr - ₹10.2 L/yr |
Ozone Overseas
Flipspaces
Eglo India
Creative Group