PRV stands for Pressure Relief Valve.
PRV is a safety device used to protect equipment or systems from overpressure.
It automatically releases excess pressure to prevent damage or failure.
PRVs are commonly used in various industries, including solar power plants.
They are typically installed in solar thermal systems to prevent pressure buildup.
PRVs are designed to open when the pressure exceeds a predetermined level and c...
The maximum voltage of a solar module depends on various factors such as the type of module and its design.
The maximum voltage of a solar module is determined by the number of solar cells connected in series.
Monocrystalline solar modules typically have a maximum voltage of around 30 to 40 volts.
Polycrystalline solar modules usually have a maximum voltage of around 25 to 35 volts.
Thin-film solar modules generally have a...
I applied via Approached by Company and was interviewed in Jul 2024. There was 1 interview round.
Experienced procurement executive with a strong track record of cost savings and supplier relationship management.
Over 10 years of experience in procurement roles
Successfully negotiated contracts resulting in significant cost savings
Implemented supplier performance metrics to improve efficiency
Led cross-functional teams to streamline procurement processes
I am currently working as a Procurement Executive responsible for sourcing, negotiating, and purchasing goods and services for the company.
Sourcing suppliers for various goods and services
Negotiating contracts and prices with vendors
Managing relationships with suppliers
Ensuring timely delivery of goods and services
Analyzing market trends and pricing to make informed purchasing decisions
Emergency response plan
Discussion about JSA prepare
I applied via Naukri.com and was interviewed in Sep 2023. There were 3 interview rounds.
Oriano Clean Energy interview questions for popular designations
I applied via Recruitment Consulltant and was interviewed in Jun 2023. There were 3 interview rounds.
For development & completing of project.
Top trending discussions
posted on 14 Oct 2021
I appeared for an interview in Apr 2024.
I appeared for an interview in Jul 2024.
As a Senior Engineer in the plant, my responsibilities include overseeing operations, managing projects, ensuring compliance with regulations, and leading a team of engineers.
Overseeing day-to-day operations in the plant
Managing projects related to plant upgrades or expansions
Ensuring compliance with safety and environmental regulations
Leading and mentoring a team of engineers
Troubleshooting technical issues and implem
Tan delta testing is conducted in power transformers to assess the insulation condition and detect any potential faults.
Tan delta testing helps in evaluating the insulation quality of power transformers.
It can detect any potential issues such as moisture, contamination, or aging of insulation materials.
By measuring the tan delta value, engineers can assess the dielectric losses in the transformer.
Regular tan delta test...
A vector group is a method used to represent the phase relationship between the primary and secondary windings of a transformer.
Vector group indicates the connection of transformer windings and the phase shift between them.
It is represented by a combination of letters and numbers, such as Yd1, Dyn11, etc.
Different vector groups have different phase relationships, affecting the transformer's performance and operation.
Ve...
Considerations when erecting an IDT (Inverter duty Transformer)
Ensure the transformer is designed for inverter duty applications
Properly size the transformer based on the inverter's output power
Consider the harmonic content of the inverter's output when selecting the transformer
Provide adequate ventilation and cooling for the transformer to handle the increased heat generated by the inverter
Ensure proper grounding and ...
Star-delta connection is a method used in power transformers to reduce starting current and improve efficiency.
Star-delta connection involves connecting the primary windings of the transformer in a star configuration during starting, and then switching to a delta configuration during normal operation.
This method helps in reducing the starting current drawn by the transformer, which is beneficial for the power system.
It...
High-tension (HT) lines use different types of conductors with varying current capacities.
Types of conductors used in HT lines include aluminum, steel, and composite materials
Aluminum conductors are commonly used due to their lightweight and high conductivity
Steel conductors are used for their strength and durability
Composite conductors are a newer technology that offer a balance of strength and conductivity
Current cap...
The distance between poles in 33KV high tension lines is typically around 50-60 meters.
The distance between poles in high tension lines is determined by factors such as terrain, voltage level, and local regulations.
In general, the distance can range from 50 to 60 meters for 33KV high tension lines.
This distance is important to ensure proper support and insulation of the conductors between poles.
The process of laying LT cables involves planning, trenching, laying the cables, jointing, testing, and backfilling.
Plan the route and depth of the trench for laying the cables.
Excavate the trench to the required depth and width.
Lay the cables in the trench, ensuring proper alignment and support.
Joint the cables together using appropriate connectors.
Test the cables for continuity and insulation resistance.
Backfill the ...
The process for attaching modules involves identifying connection points, aligning the modules, securing them in place, and testing for functionality.
Identify connection points on both modules
Align the modules properly to ensure a secure fit
Secure the modules in place using appropriate fasteners or connectors
Test the functionality of the attached modules to ensure proper connection
Seeking new challenges and opportunities for growth in a more innovative environment.
Desire for new challenges and opportunities
Seeking growth and advancement
Looking for a more innovative work environment
I come from a close-knit family of four, including my parents and younger sister.
My parents have always been supportive of my career choices and encouraged me to pursue my passion for engineering.
I have a younger sister who is currently studying computer science at university, following in my footsteps.
We enjoy spending quality time together, whether it's going on family vacations or simply having dinner at home.
posted on 14 Mar 2024
based on 6 interviews
Interview experience
based on 47 reviews
Rating in categories
Electrical Site Engineer
10
salaries
| ₹2 L/yr - ₹3.7 L/yr |
Senior Manager
9
salaries
| ₹9.8 L/yr - ₹25 L/yr |
Deputy Manager
9
salaries
| ₹7.6 L/yr - ₹10.2 L/yr |
Assistant Manager
7
salaries
| ₹3.8 L/yr - ₹9.5 L/yr |
Project Manager
7
salaries
| ₹10.5 L/yr - ₹13.6 L/yr |
UTL Solar
Danfoss Power Solutions
LM Wind Power
Senvion