Filter interviews by
The nature of work in my previous organization involved analyzing large datasets to extract insights and make data-driven decisions.
Analyzing large datasets to identify trends and patterns
Creating visualizations to communicate findings to stakeholders
Developing and implementing data-driven strategies
Collaborating with cross-functional teams to drive business outcomes
During my engineering, I worked on projects related to data analysis, machine learning, and software development.
Developed a predictive model for stock price forecasting using machine learning algorithms
Created a data visualization dashboard for analyzing customer behavior patterns
Implemented a sentiment analysis tool for social media data using natural language processing techniques
I applied via Approached by Company and was interviewed in Apr 2024. There were 2 interview rounds.
Safety. Hazard. ptw. types of ptw. Work at hight. Jsa. Crane . Confined space.
Working at heights and on hazardous scaffolding requires strict safety measures to prevent accidents and injuries.
Ensure all workers are properly trained in working at heights and using scaffolding equipment
Regularly inspect scaffolding for any damage or defects
Implement fall protection systems such as guardrails, safety nets, or personal fall arrest systems
Adhere to all relevant safety regulations and guidelines
Provid...
I applied via Approached by Company and was interviewed in Jan 2022. There was 1 interview round.
Full current in an 11 KW motor depends on the voltage and efficiency of the motor.
The full current can be calculated using the formula I = P / (sqrt(3) * V * PF * EFF)
Where P is the power in kW, V is the voltage, PF is the power factor, and EFF is the efficiency
For example, if the voltage is 415V, power factor is 0.85, and efficiency is 0.95, the full current would be around 18.5A
It is important to note that the full c...
Select feeder is a type of electrical cable used to supply power to an 11 KW motor.
Select feeder is typically a three-phase cable
It is chosen based on the motor's voltage and current requirements
The cable size is determined by the distance between the motor and the power source
Select feeder is often used in industrial settings
Examples of select feeder cables include THHN, XHHW, and MC cables
The standard frequency for motors in India is 50Hz.
The frequency of a motor determines its speed.
India uses a 50Hz frequency for its motors.
This frequency is standard across the country.
Motors designed for other frequencies may not work properly in India.
Control winding is used to operate the circuit breaker in LT panel.
Control winding is an electromagnet that generates a magnetic field to operate the circuit breaker.
It is connected to the trip coil of the circuit breaker.
When the control winding is energized, it pulls the trip coil, which releases the latch of the circuit breaker.
This causes the contacts of the circuit breaker to open and interrupt the current flow.
Co...
The problem solution in LT panel control involves identifying the issue and implementing corrective measures.
Identify the root cause of the problem
Check for loose connections and damaged components
Replace faulty components
Ensure proper grounding and insulation
Perform regular maintenance and inspections
Follow safety protocols
Test the panel after repairs
Document the repairs and maintenance
Train personnel on proper operat
I was interviewed before Feb 2023.
Expected CTC will depend on the company's salary structure and my qualifications and experience.
Expected CTC will be based on the company's salary range for the position
My qualifications and experience will also play a role in determining the expected CTC
I am open to discussing and negotiating the CTC based on the overall compensation package offered
NTPC BHEL Power Projects interview questions for popular designations
Top trending discussions
I applied via Approached by Company and was interviewed in Aug 2017. There were 5 interview rounds.
posted on 20 Feb 2015
posted on 10 Sep 2015
I applied via PLACEMENT
posted on 10 Sep 2017
I was interviewed before Sep 2016.
based on 3 interviews
Interview experience
based on 49 reviews
Rating in categories
Safety Officer
8
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Engineer
5
salaries
| ₹0 L/yr - ₹0 L/yr |
Deputy Manager
5
salaries
| ₹0 L/yr - ₹0 L/yr |
Finance Coordinator
5
salaries
| ₹0 L/yr - ₹0 L/yr |
Safety Engineer
5
salaries
| ₹0 L/yr - ₹0 L/yr |
NHPC
Power Grid Corporation of India
Tata Power
Adani Power