Filter interviews by
I applied via Approached by Company and was interviewed in Sep 2023. There were 3 interview rounds.
STEEL WEIGHT, BBS,COVER BLOCK
Top trending discussions
I applied via Walk-in and was interviewed in Sep 2023. There were 3 interview rounds.
I applied via Company Website and was interviewed before Oct 2020. There were 4 interview rounds.
SFD & BMD for a simply supported load
SFD is a diagram that shows the variation of shear force along the length of a beam
BMD is a diagram that shows the variation of bending moment along the length of a beam
For a simply supported load, the SFD will be a straight line with a constant slope
The BMD will be a parabolic curve with the maximum value at the center of the beam
The SFD and BMD can be calculated using equations an
posted on 2 Feb 2022
I applied via Walk-in and was interviewed before Feb 2021. There were 2 interview rounds.
I applied via Company Website and was interviewed before May 2021. There was 1 interview round.
Impedance is the measure of opposition to the flow of electric current in a circuit. DGR fundamental refers to the Dielectric Withstand Voltage test.
Impedance is measured in ohms and is the combination of resistance, capacitance, and inductance in a circuit.
DGR fundamental is a test to determine the maximum voltage a material can withstand without breaking down.
Basics of impedance include understanding the relationship...
I applied via Naukri.com and was interviewed in Jan 2021. There were 3 interview rounds.
Precommissioning tests of transformers ensure proper functioning and safety before energizing.
Visual inspection of transformer and its components
Measurement of insulation resistance
Measurement of winding resistance
Verification of transformer ratio and polarity
Verification of oil level and quality
Testing of protective devices
Verification of grounding
Functional testing of cooling system
Verification of nameplate data
11kv & 33kv overhead power line distribution
11kv and 33kv are common voltage levels for overhead power lines
Overhead power lines are used to distribute electricity from power stations to consumers
The voltage level determines the distance the power can be transmitted and the size of the conductors needed
Proper insulation and grounding is important for safety
Maintenance and inspection of the lines is necessary to ensure
I applied via Referral and was interviewed before Aug 2022. There were 3 interview rounds.
I applied via Naukri.com and was interviewed in Oct 2021. There was 1 interview round.
posted on 2 Feb 2024
I applied via Company Website and was interviewed before Feb 2023. There were 2 interview rounds.
About project chain cycle
Voltage drop is calculated using Ohm's Law, which states that voltage drop is equal to current multiplied by resistance.
Voltage drop can be calculated using the formula V = I * R, where V is the voltage drop, I is the current flowing through the circuit, and R is the resistance of the circuit.
To calculate voltage drop, you need to know the current flowing through the circuit and the resistance of the circuit.
For exampl...
based on 1 interview
Interview experience
based on 2 reviews
Rating in categories
Civil Site Engineer
32
salaries
| ₹2.2 L/yr - ₹4.8 L/yr |
Assistant Manager
25
salaries
| ₹3.3 L/yr - ₹5.5 L/yr |
Manager - CRM
11
salaries
| ₹4.8 L/yr - ₹7.2 L/yr |
Deputy Manager
11
salaries
| ₹4 L/yr - ₹6 L/yr |
Civil Foreman
9
salaries
| ₹2.4 L/yr - ₹5 L/yr |
Realty Assistant
Sunteck Realty
JP Infra
Balaji Enterprises