Filter interviews by
I applied via Naukri.com and was interviewed in Mar 2022. There were 2 interview rounds.
Technical
I applied via Referral and was interviewed before Jan 2021. There were 6 interview rounds.
Top trending discussions
I applied via Approached by Company and was interviewed in Jun 2024. There were 5 interview rounds.
Manager and technical officer
One split AC installation work explain
I applied via Walk-in and was interviewed before Aug 2023. There was 1 interview round.
I applied via Naukri.com and was interviewed in Feb 2024. There was 1 interview round.
I applied via Naukri.com and was interviewed in Mar 2022. There were 2 interview rounds.
Good gd
Nice one
I applied via Walk-in and was interviewed before May 2022. There were 2 interview rounds.
Power on no display cause
Check if the power cable is properly connected
Ensure the monitor is turned on and functioning
Verify if the graphics card is seated correctly
Check if the display cable is securely connected
Test the system with a different monitor or display
Diagnosis steps for no display issue
Check if the power cable is properly connected
Ensure the monitor is turned on and the brightness is adjusted
Inspect the video cable for any damages or loose connections
Try connecting the monitor to a different device to rule out compatibility issues
Check the graphics card or integrated graphics settings
Restart the computer and check if the display comes back
I applied via Walk-in and was interviewed before Dec 2021. There were 3 interview rounds.
VFD is a device used to control the speed of an electric motor by varying the frequency and voltage supplied to it.
VFD stands for Variable Frequency Drive
It converts AC power to DC power and then back to AC power at a variable frequency and voltage
It allows for precise control of motor speed and energy savings
Examples of VFD applications include HVAC systems, pumps, and conveyor belts
Screw and Centrifugal Chillers are two types of chillers used in HVAC systems. The basic difference lies in their compression technology.
Screw Chillers use a rotary screw compressor to compress the refrigerant gas while Centrifugal Chillers use a centrifugal compressor.
Screw Chillers are more efficient at part-load conditions while Centrifugal Chillers are more efficient at full-load conditions.
Screw Chillers are suita...
based on 20 reviews
Rating in categories
Territory Sales Manager
37
salaries
| ₹2 L/yr - ₹7.5 L/yr |
Assistant Manager
35
salaries
| ₹4.6 L/yr - ₹9.1 L/yr |
Branch Manager
33
salaries
| ₹7 L/yr - ₹18 L/yr |
Area Sales Manager
28
salaries
| ₹4.3 L/yr - ₹9.5 L/yr |
Service Engineer
22
salaries
| ₹1.8 L/yr - ₹4.2 L/yr |
Intex Technologies
Karbonn Mobile
Lava International
DiGiSPICE