Filter interviews by
Clear (1)
I applied via Newspaper Ad and was interviewed in Feb 2024. There was 1 interview round.
Top trending discussions
I was interviewed before Nov 2016.
Yes, I am willing to work at any location for the Senior Engineer position.
I am open to relocating for the right opportunity
I have experience working in different locations
I am flexible and adaptable to new environments
I have a proven track record of staying calm and focused in challenging situations, allowing me to problem-solve effectively.
I have experience working in high-pressure environments and have successfully delivered projects on time despite obstacles.
I am adaptable and can quickly assess a situation to determine the best course of action.
I have strong problem-solving skills and can think creatively to find solutions in ad
I applied via Approached by Company and was interviewed in Aug 2017. There were 5 interview rounds.
I applied via Naukri.com and was interviewed before Jun 2019. There were 3 interview rounds.
Implement stack data structure
Use an array or linked list to store elements
Push operation adds element to top of stack
Pop operation removes element from top of stack
Peek operation returns top element without removing it
Global variables are accessible from any part of the program and can be modified by any function.
Global variables are declared outside of any function.
They can be accessed and modified by any function in the program.
If a function modifies the value of a global variable, the new value is visible to all other functions.
Global variables can be useful for sharing data between functions.
However, overuse of global variables
Program to transpose a matrix
Iterate through rows and columns of the matrix
Swap the elements at (i,j) and (j,i) positions
Return the transposed matrix
Pre and post fix operators are used to increment or decrement a value before or after it is used in an expression.
Pre-fix operator (++x) increments the value of x and returns the new value.
Post-fix operator (x++) returns the value of x and then increments it.
Both operators can be used with variables of numeric data types.
They can also be used with pointers to increment or decrement the memory address they point to.
I applied via Referral and was interviewed before Apr 2021. There was 1 interview round.
I applied via Company Website and was interviewed in Jun 2024. There were 2 interview rounds.
Tomarrow, power system
Machine power system drive
I applied via Company Website and was interviewed in Jan 2022. There were 2 interview rounds.
I applied via Recruitment Consulltant and was interviewed in Mar 2022. There was 1 interview round.
DCS tag assigning process involves assigning unique names to process variables for monitoring and control.
DCS tag assigning process is crucial for efficient process control and monitoring.
Each tag represents a process variable and is assigned a unique name for easy identification.
Tags can be assigned manually or automatically based on the process requirements.
Tag naming conventions should be consistent and follow indus...
I applied via Company Website and was interviewed in May 2023. There were 2 interview rounds.
Equipment used in steam turbine include turbine blades, nozzles, casing, rotor, bearings, and governor.
Turbine blades: convert steam energy into mechanical energy
Nozzles: control the flow of steam into the turbine
Casing: contains and directs the steam flow through the turbine
Rotor: connected to the turbine blades and rotates to generate power
Bearings: support the rotor and reduce friction
Governor: regulates the speed o
Woodward 505 is a versatile control system used in industrial applications.
The Woodward 505 is a widely used control system in industries such as power generation, oil and gas, and marine.
It offers advanced features like PID control, sequencing, and communication capabilities.
The Woodward 505 is known for its reliability and robustness in harsh operating environments.
It can be easily integrated with various types of se
The Honeywell DCS (Distributed Control System) is a modular system consisting of controllers, I/O modules, and operator stations.
Consists of controllers, I/O modules, and operator stations
Uses a network to communicate between components
Allows for centralized control and monitoring of processes
Supports various communication protocols such as Modbus, OPC, etc.
Example: Honeywell Experion PKS
PID stands for Proportional-Integral-Derivative, a control loop feedback mechanism used in engineering.
PID is a control algorithm that calculates an error value as the difference between a desired setpoint and a measured process variable.
Proportional (P) control responds to the current error value.
Integral (I) control accumulates past errors to correct the present error.
Derivative (D) control predicts future errors bas...
To assign a new channel in Honeywell DCS, you need to access the configuration software and follow the steps to add the channel.
Access the Honeywell DCS configuration software
Navigate to the channel configuration section
Add a new channel by specifying the channel number, type, and other relevant parameters
Save the changes and verify the new channel is successfully assigned
Interlocks and permissives are safety mechanisms in place to prevent unsafe operation of boiler and turbine systems.
Interlocks prevent certain actions from taking place unless specific conditions are met
Permissives allow certain actions to take place only if specific conditions are met
Example of interlock: Boiler feed pump interlock prevents the boiler from starting unless the feed pump is running
Example of permissive:...
based on 1 interview
Interview experience
Assistant Manager
211
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Engineer
156
salaries
| ₹0 L/yr - ₹0 L/yr |
Manager
105
salaries
| ₹0 L/yr - ₹0 L/yr |
Engineer
69
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant General Manager
59
salaries
| ₹0 L/yr - ₹0 L/yr |
BHEL
Thermax Limited
Siemens
Tata Power