DCS architecture is a control system used in industrial automation to monitor and control processes.
DCS consists of multiple controllers connected to input/output devices and operator stations.
Controllers communicate with each other and with operator stations to control the process.
Redundancy is often built into DCS architecture for reliability.
Example: A typical DCS architecture includes a central control room with op...
Top trending discussions
Current is the flow of electric charge in a circuit.
Current is measured in Amperes (A)
It is the rate of flow of electric charge through a conductor
There are two types of current - AC (alternating current) and DC (direct current)
Examples of current include the flow of electrons in a wire when a light bulb is turned on
Voltage is the difference in electric potential between two points in a circuit, measured in volts.
Voltage is the driving force that pushes electric current through a circuit
It is measured in volts (V)
Voltage can be positive or negative, depending on the direction of current flow
Higher voltage means more potential energy available to move electrons
Example: A battery provides voltage to power a light bulb
Ohm's law states that the current flowing through a conductor is directly proportional to the voltage applied across it, and inversely proportional to the resistance of the conductor.
Ohm's law is expressed as V = I * R, where V is voltage, I is current, and R is resistance.
It helps in calculating the current flowing through a circuit when the voltage and resistance are known.
It can also be used to determine the resista...
posted on 12 Sep 2024
To install a temperature transmitter, you need to properly mount the transmitter, connect the wiring, configure the settings, and test the transmitter.
Mount the temperature transmitter in a suitable location near the temperature source.
Connect the wiring according to the manufacturer's instructions, ensuring proper grounding.
Configure the settings such as range, output signal, and calibration using the transmitter's di...
posted on 13 May 2024
I applied via Recruitment Consulltant and was interviewed before May 2023. There was 1 interview round.
posted on 14 Nov 2022
4-20 mA signal is preferred over 0-20 mA signal due to its ability to detect faults and provide a clear zero point.
4-20 mA signal has a clear zero point, making it easier to detect faults in the system.
It allows for a wider range of measurement values, as the 0-4 mA range can be used to indicate faults or out-of-range conditions.
4-20 mA signal is less susceptible to noise and interference compared to 0-20 mA signal.
It ...
An orifice tab is used to accurately measure the flow rate of a fluid through a pipeline.
It creates a differential pressure across the orifice plate, which is proportional to the flow rate.
The tab is placed upstream of the orifice plate to ensure accurate measurement.
The tab can be designed in different shapes and sizes depending on the application.
It is commonly used in industries such as oil and gas, chemical, and wa...
An orifice in a pipeline can be identified by measuring the pressure drop across it.
Measure the pressure drop across the pipeline using a differential pressure transmitter
Compare the pressure drop with the expected value for the given orifice size
Use a flow meter to confirm the flow rate through the orifice
Inspect the pipeline for any markings or labels indicating the presence of an orifice
Orifice tap is provided to measure the pressure drop across the orifice plate.
Measures pressure drop
Helps calculate flow rate
Used in flow measurement systems
Orifice tab is provided to indicate the size of the orifice and its flow rate.
Orifice tab helps in identifying the size of the orifice and its flow rate.
It is used in flow measurement devices like orifice plates, venturi meters, etc.
The tab is usually made of stainless steel and is welded to the orifice plate.
The tab is marked with a number or letter to indicate the size of the orifice.
The flow rate can be calculated u...
RTD measures temperature using resistance while thermistor uses resistance-temperature relationship.
RTD has a linear resistance-temperature relationship while thermistor has a non-linear one.
RTD has a higher accuracy and stability compared to thermistor.
RTD is more expensive than thermistor.
RTD is commonly used in industrial applications while thermistor is used in consumer electronics.
Examples of RTD include platinum,...
posted on 15 Apr 2023
posted on 14 Oct 2022
I applied via Recruitment Consulltant and was interviewed in Apr 2022. There were 3 interview rounds.
posted on 15 Nov 2022
I applied via Referral and was interviewed before Nov 2021. There were 4 interview rounds.
Calibration of pressure and temperature involves adjusting instruments to ensure accurate readings.
Calibration involves comparing the readings of a device to a known standard and making adjustments if necessary.
For pressure calibration, a pressure gauge is connected to a reference standard to check accuracy.
Temperature calibration may involve using a temperature bath with known values to adjust a thermometer.
Regular ca...
Interview experience
based on 2 reviews
Rating in categories
Field Operator
72
salaries
| ₹15 L/yr - ₹36 L/yr |
Operations Engineer
34
salaries
| ₹20.4 L/yr - ₹65 L/yr |
DCS Operator
32
salaries
| ₹24 L/yr - ₹42 L/yr |
Instrumentation Technician
23
salaries
| ₹3.8 L/yr - ₹13 L/yr |
Operator
22
salaries
| ₹24 L/yr - ₹31.5 L/yr |
Indian Oil Corporation
Reliance Industries
Bharat Petroleum
Hindustan Petroleum