i
Johnson Controls
Filter interviews by
I applied via Recruitment Consultant and was interviewed in Feb 2021. There were 6 interview rounds.
I applied via Recruitment Consultant and was interviewed in Feb 2021. There were 4 interview rounds.
I was interviewed before Aug 2021.
Communication protocols are a set of rules that govern the exchange of data between devices or systems.
Protocols define the format, timing, sequencing, and error checking of data transmission.
Examples include TCP/IP, HTTP, FTP, SMTP, and Bluetooth.
Protocols can be classified as wired or wireless, serial or parallel, synchronous or asynchronous.
They are essential for ensuring interoperability and reliable communication ...
I have worked as a Test Engineer in multiple roles and projects.
Tested software applications for functionality, performance, and reliability.
Developed and executed test plans, test cases, and test scripts.
Identified and reported software defects, and worked with developers to resolve them.
Collaborated with cross-functional teams to ensure quality standards were met.
Participated in requirement analysis and design review...
Johnson Controls interview questions for popular designations
Get interview-ready with Top Johnson Controls Interview Questions
The P-H chart is a graphical representation of the properties of refrigerants used in air conditioning systems.
The chart shows the relationship between pressure, enthalpy, and temperature of the refrigerant.
It helps in selecting the right refrigerant for a particular application.
It also helps in troubleshooting air conditioning systems.
The chart is used to determine the state of the refrigerant (saturated liquid, satur...
Subcool and superheat are terms used in refrigeration and air conditioning to describe the state of refrigerant in a system.
Subcool refers to the temperature of a liquid refrigerant that is below its boiling point.
Superheat refers to the temperature of a vapor refrigerant that is above its boiling point.
Subcooling and superheating are important for ensuring the proper functioning of a refrigeration or air conditioning ...
Scroll compressor uses two interleaved spiral scrolls to compress air or refrigerant.
Scroll compressor has fewer moving parts and is more efficient than traditional compressors.
The scrolls are made of a durable material like aluminum or steel.
The scrolls rotate in opposite directions, creating pockets of air or refrigerant that are compressed as they move towards the center.
Scroll compressors are commonly used in air c...
I applied via Referral and was interviewed before Mar 2021. There was 1 interview round.
I applied via Recruitment Consulltant and was interviewed before Mar 2021. There was 1 interview round.
I applied via Naukri.com and was interviewed before Aug 2021. There were 3 interview rounds.
Golden rules of Account
Maintain accurate records
Separate personal and business finances
Reconcile accounts regularly
Monitor cash flow
Stay organized and up-to-date with tax laws
Top trending discussions
Interview experience
based on 2.8k reviews
Rating in categories
Assistant Manager
1.2k
salaries
| ₹4.5 L/yr - ₹12 L/yr |
Senior Executive
1.1k
salaries
| ₹3 L/yr - ₹9 L/yr |
Deputy Manager
647
salaries
| ₹6.8 L/yr - ₹12.6 L/yr |
Manager
353
salaries
| ₹7.8 L/yr - ₹17.4 L/yr |
Applications Engineer
346
salaries
| ₹3.9 L/yr - ₹11.5 L/yr |
Siemens
Honeywell Automation
Schneider Electric
ABB