Filter interviews by
I applied via Company Website and was interviewed in Jul 2023. There was 1 interview round.
25 kv Railway work involves the installation and maintenance of electrical systems for railway operations.
Installation and maintenance of 25 kv electrical systems
Ensuring safety protocols are followed
Troubleshooting and resolving electrical issues
Coordinating with team members and stakeholders
Adhering to railway regulations and standards
Top trending discussions
Designing beams and columns involves determining the size, material, and layout to support the required loads.
Consider the type of structure and the loads it will bear
Calculate the required dimensions and reinforcement based on structural analysis
Select appropriate materials such as steel or concrete
Ensure proper connections and detailing for stability and safety
Limit state of serviceability refers to the condition where a structure is still functioning properly without any excessive deflection or deformation.
Limit state of serviceability ensures that a structure remains usable and safe for occupants.
It involves checking factors like deflection, vibration, cracking, and durability.
For example, a bridge should not deflect excessively under the weight of traffic to maintain serv...
I was interviewed in Dec 2024.
I applied via Walk-in and was interviewed before May 2021. There were 2 interview rounds.
CODAL provisions for concrete refer to the guidelines and regulations set by relevant authorities, while commands of software are the specific instructions or functions within a software program.
CODAL provisions for concrete include specifications for mix design, strength requirements, and durability standards.
Commands of software for site engineers may include functions for structural analysis, quantity takeoff, and p...
The size of a concrete cube is typically 150mm x 150mm x 150mm for standard testing purposes.
Standard size for concrete cube is 150mm x 150mm x 150mm
Used for testing the compressive strength of concrete
Other sizes may be used for specific projects or requirements
posted on 31 Oct 2024
I applied via Naukri.com
Foundation footing requires a minimum cover of 50mm to 75mm for reinforcement protection.
Minimum cover of 50mm to 75mm is required for foundation footing to protect the reinforcement from corrosion and provide adequate strength.
The cover requirement may vary based on the type of soil, environmental conditions, and structural design.
Proper cover ensures durability and stability of the foundation.
In some cases, additiona...
The cover required for shuttering column up to FFL depends on the type of concrete being used and the environmental conditions.
Cover required for shuttering column up to FFL typically ranges from 25mm to 50mm.
Factors such as type of concrete mix, exposure conditions, and structural requirements can influence the required cover.
For example, in harsh environmental conditions or high-strength concrete, a higher cover may ...
I applied via Company Website and was interviewed in Jun 2023. There were 3 interview rounds.
Initial and Routine Pile Load Tests are conducted to assess the load-bearing capacity and performance of piles.
Initial Pile Load Test is performed on a single pile to determine its ultimate load capacity and settlement behavior.
Routine Pile Load Test is conducted on a representative sample of piles to verify the design assumptions and ensure the desired performance.
Initial Pile Load Test involves applying a gradually i...
Performance test of elastomeric bearings evaluates their ability to withstand load, deformation, and environmental conditions.
Performance test assesses the load-carrying capacity of elastomeric bearings.
It measures the deformation and displacement under different loads.
Tests evaluate the behavior of bearings under various environmental conditions like temperature and moisture.
Performance tests ensure the durability, st...
posted on 3 May 2023
I applied via Campus Placement and was interviewed in Apr 2023. There were 3 interview rounds.
posted on 9 Aug 2023
I was interviewed in Feb 2023.
FAR stands for Floor Area Ratio, which is the ratio of a building's total floor area to the size of the piece of land on which it is built. Floor area refers to the total area of a floor in a building, carpet area is the area within the walls, and built-up area includes carpet area plus the thickness of walls.
FAR (Floor Area Ratio) is the ratio of a building's total floor area to the size of the land it is built on.
Flo...
I applied via Walk-in and was interviewed in Feb 2023. There were 3 interview rounds.
Metro project Ugrider casting
based on 1 interview
Interview experience
based on 1 review
Rating in categories
Works Engineer
94
salaries
| ₹3.7 L/yr - ₹8.4 L/yr |
Civil Engineer
69
salaries
| ₹2.4 L/yr - ₹8 L/yr |
Assistant Manager
18
salaries
| ₹9 L/yr - ₹12.5 L/yr |
Civil Site Engineer
17
salaries
| ₹2 L/yr - ₹7 L/yr |
Deputy General Manager
16
salaries
| ₹17 L/yr - ₹27 L/yr |
Rail Vikas Nigam
NBCC
Engineers India
Mecon