I applied via Walk-in and was interviewed in Oct 2022. There were 2 interview rounds.
A 3 phase electrical system consists of three conductors carrying alternating current with a phase difference of 120 degrees.
Consists of three conductors carrying alternating current
Phases are 120 degrees apart
Commonly used in industrial and commercial applications
I applied via Walk-in and was interviewed in Aug 2020. There were 3 interview rounds.
Power factor is a measure of how effectively electrical power is being used in a circuit.
Power factor is the ratio of real power (in watts) to apparent power (in volt-amperes).
It indicates the efficiency of electrical power consumption in a circuit.
A power factor of 1 means all the power is being used effectively, while a power factor less than 1 indicates wastage of power.
Inductive loads like motors and transformers h...
A motor is an electrical device that converts electrical energy into mechanical energy.
Motors are used in a variety of applications, from powering industrial machinery to driving household appliances.
There are different types of motors, including AC motors, DC motors, and stepper motors.
Motors can be controlled using various methods, such as variable frequency drives and soft starters.
Proper maintenance and inspection ...
A star delta starter is used to reduce the starting current of a motor.
The motor is initially connected in star configuration to reduce the voltage across each winding.
After a set time, the motor is switched to delta configuration for normal operation.
The control diagram includes a timer, contactors, and overload protection.
The timer delays the switching from star to delta configuration.
The contactors are used to switc...
DOL starter is used in single-phase induction motors and small three-phase motors.
DOL starter stands for Direct-On-Line starter.
It is used to start and stop the motor directly without any intermediate control.
It is commonly used in single-phase induction motors and small three-phase motors.
DOL starter provides full voltage to the motor during starting, which can cause high starting current.
It consists of a contactor, t...
The resistive load equation is used to calculate the power consumed by a resistive load.
The equation is P = V^2/R, where P is power, V is voltage, and R is resistance.
This equation is used in electrical engineering to determine the power consumption of resistive loads such as heaters and incandescent light bulbs.
The equation can also be rearranged to solve for voltage or resistance, depending on the information given.
I...
Asynchronous motors are used for various purposes due to their simple design and low cost.
Asynchronous motors are commonly used in industrial applications such as pumps, fans, and compressors.
They are also used in household appliances like washing machines and refrigerators.
Asynchronous motors are preferred for their low maintenance and high reliability.
They are also used in electric vehicles and hybrid cars.
Asynchrono...
Transformers are classified based on their construction, purpose, and voltage level.
Based on construction: core type, shell type, and Berry type
Based on purpose: power transformer, distribution transformer, isolation transformer, autotransformer, etc.
Based on voltage level: step-up transformer, step-down transformer, and isolation transformer
Other classifications: single-phase transformer, three-phase transformer, and ...
India has a total installed capacity of over 370 GW as of 2021.
India's power generation capacity has been growing rapidly in recent years
The country has set a target of achieving 450 GW of renewable energy capacity by 2030
India is one of the world's largest producers of renewable energy, with a capacity of over 100 GW
Coal still accounts for a significant portion of India's power generation, but the government is workin
Chopper circuits are used to convert a fixed DC voltage to a variable DC voltage.
Chopper circuits are also known as DC-DC converters.
They are used in applications such as battery charging, motor control, and renewable energy systems.
Chopper circuits use high-frequency switching to control the output voltage.
Examples of chopper circuits include buck converters, boost converters, and buck-boost converters.
Top trending discussions
I applied via Company Website and was interviewed in Jul 2022. There was 1 interview round.
I applied via Naukri.com and was interviewed in Dec 2021. There were 3 interview rounds.
I applied via Naukri.com and was interviewed in Feb 2021. There was 1 interview round.
The full form of A.C. current is Alternating Current.
A.C. current stands for Alternating Current.
It is a type of electric current that periodically reverses direction.
It is commonly used in household electrical systems and power grids.
Unlike direct current (D.C.), A.C. current can easily be transformed to different voltage levels.
Examples of A.C. current include the electricity supplied by utility companies and the pow
The full form of D.C. current is Direct Current.
D.C. stands for Direct Current.
It is a type of electrical current that flows in one direction only.
It is commonly used in batteries and electronic devices.
The opposite of D.C. current is A.C. current, which alternates direction.
D.C. current is measured in amperes (A).
I applied via Company Website and was interviewed in Jan 2023. There were 3 interview rounds.
posted on 20 Jul 2021
I applied via campus placement at Vivekanand Education Societys Vivekanand Polytechnic, Nagpur and was interviewed in Jun 2021. There were 4 interview rounds.
Power factor is a measure of how efficiently electrical power is being used. It can be improved by using power factor correction techniques. ACB and VCB are types of circuit breakers used in electrical systems.
Power factor is the ratio of real power to apparent power in an electrical system.
A power factor of 1 indicates that all the power is being used efficiently, while a power factor less than 1 indicates inefficienc...
A DOL starter is a direct online motor starter that is used to start and stop motors without any speed control.
DOL starter consists of a contactor, overload relay, start and stop push buttons, and power circuit
The contactor connects the motor to the power supply when the start button is pressed
The overload relay protects the motor from overloading and overheating
The stop button breaks the circuit and stops the motor
Exa...
The most commonly used wiring in home or domestic wiring is PVC insulated copper wires.
PVC insulated copper wires are used for lighting and power circuits.
Flat PVC insulated cables are used for submersible pumps.
Armoured cables are used for outdoor wiring.
Flexible cords are used for appliances and equipment.
Wires with different colors are used for easy identification of circuits.
I applied via Company Website and was interviewed in Jul 2022. There was 1 interview round.
I applied via Naukri.com and was interviewed in Dec 2021. There were 3 interview rounds.
I applied via Naukri.com and was interviewed in Feb 2021. There was 1 interview round.
The full form of A.C. current is Alternating Current.
A.C. current stands for Alternating Current.
It is a type of electric current that periodically reverses direction.
It is commonly used in household electrical systems and power grids.
Unlike direct current (D.C.), A.C. current can easily be transformed to different voltage levels.
Examples of A.C. current include the electricity supplied by utility companies and the pow
The full form of D.C. current is Direct Current.
D.C. stands for Direct Current.
It is a type of electrical current that flows in one direction only.
It is commonly used in batteries and electronic devices.
The opposite of D.C. current is A.C. current, which alternates direction.
D.C. current is measured in amperes (A).
based on 6 reviews
Rating in categories
Area Sales Executive
393
salaries
| ₹2.4 L/yr - ₹10.2 L/yr |
Senior Area Sales Executive
249
salaries
| ₹4 L/yr - ₹11.6 L/yr |
Assistant Manager
240
salaries
| ₹6 L/yr - ₹13 L/yr |
Service Engineer
240
salaries
| ₹2.5 L/yr - ₹9.5 L/yr |
Regional Sales Manager
160
salaries
| ₹10.6 L/yr - ₹37 L/yr |
Amara Raja Energy & Mobility
HBL Power Systems
Su-Kam Power Systems
Luminous Power Technologies