Filter interviews by
Intermediate roll is a crucial component in the production process, used for shaping and forming materials.
Intermediate roll is typically made of high-quality steel or other durable materials.
It is used in various industrial processes such as rolling mills, paper mills, and metal forming.
The profile of intermediate roll includes dimensions like diameter, length, and surface finish.
It plays a key role in shaping and for
I was interviewed in Jul 2022.
I have experience in dealing with project delays and have successfully implemented strategies to get the project back on track.
Identify the root cause of the delay
Re-evaluate the project timeline and adjust accordingly
Communicate with stakeholders and team members to ensure everyone is aware of the delay and the plan to get back on track
Implement strategies such as increasing resources or adjusting project scope to mak...
Safety test
I applied via Walk-in and was interviewed before Mar 2020. There were 6 interview rounds.
To manage the site, I will focus on communication, organization, safety, and quality control.
Regular communication with team members and stakeholders
Establishing clear goals and timelines
Ensuring compliance with safety regulations and protocols
Implementing quality control measures to ensure work meets standards
Regular site inspections to identify and address issues
Maintaining accurate records and documentation
Managing ...
Legal documentation refers to the written agreements, contracts, permits, licenses, and other legal papers required for a construction project.
Building permits
Environmental permits
Contract agreements
Insurance policies
Safety regulations
Employment contracts
Liability waivers
Job planning involves creating a detailed plan for completing a project, while cash flow refers to the movement of money in and out of a business.
Job planning involves breaking down a project into smaller tasks and assigning timelines and resources to each task.
Cash flow management involves monitoring the inflow and outflow of money in a business to ensure that there is enough cash to cover expenses.
Effective job plann...
Excellent Projects interview questions for popular designations
Top trending discussions
I applied via LinkedIn and was interviewed in Dec 2022. There were 6 interview rounds.
I applied via Referral and was interviewed in Oct 2022. There were 2 interview rounds.
I applied via Naukri.com and was interviewed before Oct 2021. There was 1 interview round.
Safety precautions include wearing appropriate PPE, following proper procedures, and regular equipment maintenance. Steel wastage control involves accurate BBS preparation and monitoring on site.
Wear appropriate PPE such as hard hats, safety glasses, and steel-toed boots
Follow proper procedures for handling equipment and materials
Regularly maintain equipment to ensure it is in good working condition
Prepare accurate BBS...
The skill for finishing activities till handover to client requires attention to detail, effective communication, and time management.
Create a detailed project plan with clear timelines and milestones
Regularly communicate progress and any potential delays to the client
Ensure all tasks are completed to a high standard and meet client expectations
Conduct thorough testing and quality assurance before handover
Provide clear...
I applied via Referral and was interviewed in Jan 2022. There were 2 interview rounds.
I applied via Naukri.com and was interviewed in Nov 2021. There was 1 interview round.
Section box is used to isolate a portion of the model for viewing/editing. Scope box is used to define the boundary of a view.
Section box is used to cut a section of the model for better visibility and editing.
Scope box is used to define the boundary of a view and control the visibility of elements outside the boundary.
Section box is used in 3D views while scope box is used in plan, section, elevation views.
Section box...
Linking CAD files in Revit provides better control and flexibility.
Linked CAD files can be updated without affecting the Revit model.
Linked CAD files can be managed separately from the Revit model.
Linked CAD files can be controlled with visibility settings.
Importing CAD files can increase file size and slow down performance.
Linking CAD files allows for better collaboration with external consultants.
Linked CAD files can
There are three types of Revit file linking process: Overlay, Attachment, and Imported CAD. We use it to link external files to our Revit project.
Overlay: used to display the linked file on top of the host model
Attachment: used to attach the linked file to the host model
Imported CAD: used to import CAD files into Revit
We use linking process to collaborate with other disciplines, to reference external files, and to crea...
posted on 17 Mar 2021
I applied via Naukri.com and was interviewed in Feb 2021. There was 1 interview round.
The input required for a single line diagram includes information about the electrical system components and their connections.
Information about the electrical system components such as generators, transformers, switchgear, and loads
The connections between these components including the type of connection and the ratings of the equipment
The voltage level of the system and the type of system grounding
The protective devi...
Motor feeder and power feeder requirements are essential for electrical design engineers to ensure proper functioning of electrical systems.
Motor feeder requirements include selecting the appropriate motor size, voltage, and current rating.
Power feeder requirements involve determining the load requirements and selecting the appropriate cable size and voltage drop.
Proper coordination and protection devices such as circu...
Hazardous area classification involves categorizing areas based on the presence of flammable gases, vapors, or dusts.
Hazardous areas are classified based on the likelihood of the presence of flammable substances.
Temperature Class refers to the maximum surface temperature of equipment that can be used in a hazardous area.
Hazardous areas are categorized into zones based on the frequency and duration of the presence of fl...
1.25 FLA is taken for circuit breaker and 1.5 times for contactor to ensure protection against overloading and short circuits.
1.25 FLA is the maximum current that a circuit breaker can handle without tripping.
1.5 times FLA is taken for contactor to ensure that it can handle the inrush current during motor starting.
This also provides protection against short circuits and overloading.
For example, if the full load current...
Percentage Impedance is a measure of the voltage drop in a transformer during a short circuit. It determines the ability of the transformer to withstand short circuit currents.
Percentage Impedance is the ratio of the rated voltage of a transformer to the short circuit current at its terminals, expressed as a percentage.
It represents the internal impedance of the transformer and is usually provided by the manufacturer.
A...
Protection schemes for transformers and generators.
Overcurrent protection
Differential protection
Distance protection
Restricted earth fault protection
Backup protection
Buchholz relay protection
Thermal overload protection
Under/over voltage protection
Neutral grounding protection
Cable sizing is calculated using the formula for voltage drop, which takes into account resistive and inductive drop. Voltage drop is limited to 5% to ensure efficient power transmission.
Cable sizing is determined by calculating the voltage drop using the formula: VD = (I * L * R * 2) / 1000
Resistive drop is calculated using Ohm's Law: Vr = I * R
Inductive drop is calculated using the formula: Vi = I * X
Voltage drop is ...
Earthing calculation standards and resistances for substation and lightning protection.
Earthing calculation involves determining the resistance of the earth electrode system.
The standard used for earthing calculation is IEEE 80.
The resistance in substation should be less than 1 ohm.
The resistance for lightning protection should be less than 10 ohms.
Factors affecting earthing calculation include soil resistivity, electr...
The motor contribution to the short circuit current is significant and needs to be considered in electrical design.
The motor's impedance affects the short circuit current level.
The motor's starting current can cause a significant increase in short circuit current.
The motor's location in the electrical system can affect its contribution to the short circuit current.
The motor's size and type can also impact its contribut...
Types of contactors include AC, DC, reversing, and definite purpose. Maximum efficiency of transformer depends on load and design.
AC contactors are used for alternating current circuits
DC contactors are used for direct current circuits
Reversing contactors are used to reverse the direction of current flow
Definite purpose contactors are designed for specific applications
Maximum efficiency of transformer is achieved at fu...
Non-linear loads are electrical devices that do not have a linear relationship between the voltage and current.
Non-linear loads draw non-sinusoidal current waveforms.
They can cause harmonic distortion in the electrical system.
Examples of non-linear loads include computers, televisions, and variable speed drives.
Linear loads have a linear relationship between voltage and current, such as incandescent light bulbs.
Linear
Explanation of lighting calculation, light loss factor, utilisation factor, and minimum lux required in substation.
Lighting calculation involves determining the amount of light required in a space.
Light loss factor is the reduction in light output due to factors such as dirt, dust, and aging of lamps.
Utilisation factor is the ratio of light received by a surface to the total light output of the lamps.
Formula for lighti...
APFC stands for Automatic Power Factor Correction. Series reactor is a device used to limit current flow.
APFC is a system that automatically corrects the power factor of an electrical network.
It uses capacitors to improve the power factor and reduce energy consumption.
Series reactor is a device that is used to limit the flow of current in a circuit.
It is used to protect equipment from overvoltage and to reduce harmonic...
based on 34 reviews
Rating in categories
Mechanical Engineer
27
salaries
| ₹2.4 L/yr - ₹8 L/yr |
Safety Officer
13
salaries
| ₹2.5 L/yr - ₹4.8 L/yr |
Mechanical Maintenance Engineer
9
salaries
| ₹2.4 L/yr - ₹6.5 L/yr |
Maintenance Engineer
8
salaries
| ₹3.6 L/yr - ₹10 L/yr |
QA QC Engineer
7
salaries
| ₹3.3 L/yr - ₹6.2 L/yr |
Reliance Industries
TCS
Infosys
Wipro