PM of AHU involves regular maintenance and cleaning of the unit and its components.
Regular inspection and cleaning of filters, coils, and fans
Checking and adjusting belts and pulleys
Testing and calibrating sensors and controls
Lubricating moving parts
Recording and analyzing performance data
Planning and scheduling maintenance activities
Ensuring compliance with safety and environmental regulations
Top trending discussions
HVAC technicians work on all types of heating, ventilation, and air conditioning systems.
HVAC technicians are responsible for installing, maintaining, and repairing heating, ventilation, and air conditioning systems in residential, commercial, and industrial buildings.
They work on various types of HVAC equipment such as furnaces, air conditioners, heat pumps, and boilers.
HVAC technicians must be knowledgeable about ele...
There are two main types of compressors: positive displacement compressors and dynamic compressors.
Positive displacement compressors include reciprocating, rotary, and scroll compressors.
Dynamic compressors include centrifugal and axial compressors.
Each type of compressor has its own advantages and disadvantages based on the specific application.
Reciprocating compressors are commonly used in household refrigerators, wh...
Differential temperature is the difference in temperature between two points or objects.
Differential temperature is commonly used in HVAC systems to measure the temperature difference between the supply and return air.
It can also refer to the temperature difference across a heat exchanger or between two different rooms in a building.
Calculating the differential temperature helps in determining the efficiency of a syste
I applied via Indeed and was interviewed in Mar 2024. There was 1 interview round.
An HVAC system is a heating, ventilation, and air conditioning system that regulates temperature, humidity, and air quality in a building.
HVAC systems control temperature, humidity, and air quality in a building
They consist of components such as furnaces, air conditioners, ductwork, and thermostats
HVAC systems can be centralized or decentralized
Regular maintenance is important to ensure efficient operation
Validation process is a methodical approach to ensuring that a system or process meets predefined requirements and specifications.
Validation process involves testing and verifying that a system or process performs as intended.
It includes documenting and analyzing results to ensure compliance with standards.
Validation process may involve validation protocols, test plans, and validation reports.
Examples of validation pro...
Differential pressure is the difference in pressure between two points in a system.
Differential pressure is used to measure the pressure drop across a filter, coil, or other HVAC component.
It is important in HVAC systems to ensure proper airflow and efficiency.
Differential pressure is typically measured in inches of water column (in. w.c.) or pascals (Pa).
Relative humidity is the amount of water vapor present in air compared to the maximum amount it can hold at a specific temperature, while humidity is the general term for the amount of water vapor in the air.
Relative humidity is expressed as a percentage, while humidity is a general term for the amount of water vapor in the air.
Relative humidity changes with temperature, while humidity is a measure of the water vapor c...
Maintaining relative humidity and temperature levels in HVAC systems is crucial for optimal performance and comfort.
Regularly monitor and adjust the humidity and temperature levels using a humidistat and thermostat.
Ensure proper ventilation to prevent moisture buildup and maintain air quality.
Use dehumidifiers or humidifiers as needed to achieve the desired RH levels.
Inspect and maintain HVAC equipment regularly to ens...
posted on 11 Aug 2023
I applied via Newspaper Ad
Work period time in the papaer
Latesh work day period time declaration
Not good last same time the request coloring maintenance worm
I applied via Approached by Company and was interviewed in Jun 2022. There were 2 interview rounds.
Hvac technician service
I applied via Campus Placement and was interviewed before Jan 2021. There were 3 interview rounds.
The sanitizer bottle is a tool.
A tool is a device used to perform a specific task.
The sanitizer bottle is used to dispense sanitizer.
It does not have any moving parts or complex mechanisms.
It is a simple tool that can be operated by hand.
I applied via Referral and was interviewed before Mar 2022. There was 1 interview round.
I applied via Approached by Company and was interviewed in Mar 2024. There was 1 interview round.
Regular maintenance of HVAC systems is essential for optimal performance and energy efficiency.
Change air filters regularly to ensure proper airflow and indoor air quality.
Inspect and clean evaporator and condenser coils to improve efficiency.
Check refrigerant levels and ensure there are no leaks.
Inspect and clean ductwork to prevent blockages and improve airflow.
Regularly schedule professional maintenance to identify ...
Differential pressure is the difference in pressure between two points in a system.
Difference pressure, also known as differential pressure, is the variance in pressure between two points in a system.
It is commonly used in HVAC systems to measure the pressure drop across filters, coils, or ducts.
Differential pressure is crucial for ensuring proper airflow and system efficiency.
It is typically measured in units such as ...
Maintaining Rh and temperature involves monitoring and adjusting humidity levels and air temperature in a controlled environment.
Regularly monitor humidity levels using a hygrometer
Adjust humidity levels by using a humidifier or dehumidifier as needed
Monitor and adjust air temperature using a thermostat
Ensure proper ventilation to prevent humidity buildup
Use HVAC systems to regulate both humidity and temperature
Maintaining differential pressure involves regular monitoring, adjusting airflow, and ensuring proper equipment functioning.
Regularly monitor differential pressure readings to ensure they are within the desired range
Adjust airflow by adjusting dampers, fan speeds, or air vents to maintain the correct pressure
Ensure proper functioning of equipment such as filters, fans, and ductwork to prevent pressure imbalances
Perform...
Relative humidity (RH) is the amount of water vapor present in air compared to the maximum amount that could be held at that temperature, while absolute humidity is the actual amount of water vapor present in the air.
Relative humidity is expressed as a percentage, while absolute humidity is expressed in grams of water vapor per cubic meter of air.
Relative humidity changes with temperature, while absolute humidity remai...
Team Member
3.9k
salaries
| ₹1.8 L/yr - ₹9.8 L/yr |
Analytical Scientist
835
salaries
| ₹3.5 L/yr - ₹13.5 L/yr |
Assistant Manager
788
salaries
| ₹4.4 L/yr - ₹16.7 L/yr |
Senior Team Member
540
salaries
| ₹3 L/yr - ₹12 L/yr |
Area Sales Manager
466
salaries
| ₹4.8 L/yr - ₹12.8 L/yr |
Sun Pharmaceutical Industries
Cipla
Biocon Limited
Lupin