I applied via Walk-in and was interviewed in Jul 2024. There was 1 interview round.
Orifice std refers to standard orifice sizes used in engineering. Types of taps include flange taps, corner taps, and D and D/2 taps.
Orifice std refers to standard sizes of orifices used in flow measurement
Types of taps include flange taps, corner taps, and D and D/2 taps
Flange taps are used for large pipes, corner taps for small pipes, and D and D/2 taps for general applications
Pressure gauge operating range refers to the minimum and maximum pressure values that the gauge can accurately measure.
Pressure gauge operating range is typically specified by the manufacturer.
It is important to ensure that the pressure being measured falls within the gauge's operating range to ensure accurate readings.
For example, a pressure gauge with an operating range of 0-100 psi should not be used to measure pres
Straight length requirements for orifice flow element ensure accurate measurement by allowing flow to stabilize before reaching the element.
Straight length requirements typically range from 10 to 44 pipe diameters upstream and 5 to 22 pipe diameters downstream of the orifice.
These requirements help prevent flow disturbances and ensure accurate measurement of flow rate.
For example, if the pipe diameter is 4 inches, the ...
I applied via Referral and was interviewed before May 2023. There were 2 interview rounds.
I applied via Naukri.com and was interviewed in Oct 2022. There were 2 interview rounds.
I rate myself 8 out of 10 for power electronics circuit designing.
I have extensive experience in designing power electronics circuits for various applications.
I am proficient in using simulation tools like LTSpice and MATLAB for circuit analysis and design.
I have designed and implemented several power electronics circuits, including DC-DC converters, inverters, and motor drives.
I keep myself updated with the latest tre...
I am currently working as a Sr. Engineer in design.
I am responsible for designing and developing new products.
I collaborate with cross-functional teams to gather requirements and ensure design feasibility.
I use various techniques like brainstorming, prototyping, and simulation to solve problems.
I encourage open communication and teamwork to address any issues that arise within the team.
I also conduct regular design rev...
posted on 27 Jul 2024
I applied via campus placement at Lokmanya Tilak College of Engineering, Navi Mumbai and was interviewed before Jul 2023. There were 2 interview rounds.
Technical test of 1 hr
I am an experienced Electrical Design Engineer with a strong background in designing and implementing electrical systems.
I have a Bachelor's degree in Electrical Engineering from XYZ University.
I have worked for 5+ years in the field, designing electrical systems for commercial buildings.
I am proficient in AutoCAD and other design software, ensuring accurate and efficient designs.
I have a strong understanding of electr...
posted on 17 Mar 2021
I applied via Naukri.com and was interviewed in Feb 2021. There was 1 interview round.
The input required for a single line diagram includes information about the electrical system components and their connections.
Information about the electrical system components such as generators, transformers, switchgear, and loads
The connections between these components including the type of connection and the ratings of the equipment
The voltage level of the system and the type of system grounding
The protective devi...
Motor feeder and power feeder requirements are essential for electrical design engineers to ensure proper functioning of electrical systems.
Motor feeder requirements include selecting the appropriate motor size, voltage, and current rating.
Power feeder requirements involve determining the load requirements and selecting the appropriate cable size and voltage drop.
Proper coordination and protection devices such as circu...
Hazardous area classification involves categorizing areas based on the presence of flammable gases, vapors, or dusts.
Hazardous areas are classified based on the likelihood of the presence of flammable substances.
Temperature Class refers to the maximum surface temperature of equipment that can be used in a hazardous area.
Hazardous areas are categorized into zones based on the frequency and duration of the presence of fl...
1.25 FLA is taken for circuit breaker and 1.5 times for contactor to ensure protection against overloading and short circuits.
1.25 FLA is the maximum current that a circuit breaker can handle without tripping.
1.5 times FLA is taken for contactor to ensure that it can handle the inrush current during motor starting.
This also provides protection against short circuits and overloading.
For example, if the full load current...
Percentage Impedance is a measure of the voltage drop in a transformer during a short circuit. It determines the ability of the transformer to withstand short circuit currents.
Percentage Impedance is the ratio of the rated voltage of a transformer to the short circuit current at its terminals, expressed as a percentage.
It represents the internal impedance of the transformer and is usually provided by the manufacturer.
A...
Protection schemes for transformers and generators.
Overcurrent protection
Differential protection
Distance protection
Restricted earth fault protection
Backup protection
Buchholz relay protection
Thermal overload protection
Under/over voltage protection
Neutral grounding protection
Cable sizing is calculated using the formula for voltage drop, which takes into account resistive and inductive drop. Voltage drop is limited to 5% to ensure efficient power transmission.
Cable sizing is determined by calculating the voltage drop using the formula: VD = (I * L * R * 2) / 1000
Resistive drop is calculated using Ohm's Law: Vr = I * R
Inductive drop is calculated using the formula: Vi = I * X
Voltage drop is ...
Earthing calculation standards and resistances for substation and lightning protection.
Earthing calculation involves determining the resistance of the earth electrode system.
The standard used for earthing calculation is IEEE 80.
The resistance in substation should be less than 1 ohm.
The resistance for lightning protection should be less than 10 ohms.
Factors affecting earthing calculation include soil resistivity, electr...
The motor contribution to the short circuit current is significant and needs to be considered in electrical design.
The motor's impedance affects the short circuit current level.
The motor's starting current can cause a significant increase in short circuit current.
The motor's location in the electrical system can affect its contribution to the short circuit current.
The motor's size and type can also impact its contribut...
Types of contactors include AC, DC, reversing, and definite purpose. Maximum efficiency of transformer depends on load and design.
AC contactors are used for alternating current circuits
DC contactors are used for direct current circuits
Reversing contactors are used to reverse the direction of current flow
Definite purpose contactors are designed for specific applications
Maximum efficiency of transformer is achieved at fu...
Non-linear loads are electrical devices that do not have a linear relationship between the voltage and current.
Non-linear loads draw non-sinusoidal current waveforms.
They can cause harmonic distortion in the electrical system.
Examples of non-linear loads include computers, televisions, and variable speed drives.
Linear loads have a linear relationship between voltage and current, such as incandescent light bulbs.
Linear
Explanation of lighting calculation, light loss factor, utilisation factor, and minimum lux required in substation.
Lighting calculation involves determining the amount of light required in a space.
Light loss factor is the reduction in light output due to factors such as dirt, dust, and aging of lamps.
Utilisation factor is the ratio of light received by a surface to the total light output of the lamps.
Formula for lighti...
APFC stands for Automatic Power Factor Correction. Series reactor is a device used to limit current flow.
APFC is a system that automatically corrects the power factor of an electrical network.
It uses capacitors to improve the power factor and reduce energy consumption.
Series reactor is a device that is used to limit the flow of current in a circuit.
It is used to protect equipment from overvoltage and to reduce harmonic...
based on 1 review
Rating in categories
BIM Engineer
45
salaries
| ₹3.7 L/yr - ₹11 L/yr |
Section Engineer
39
salaries
| ₹7.2 L/yr - ₹14.4 L/yr |
CAD Engg
35
salaries
| ₹2.7 L/yr - ₹6 L/yr |
Site Engineer
31
salaries
| ₹4.8 L/yr - ₹10 L/yr |
Structural Engineer
12
salaries
| ₹6 L/yr - ₹12.3 L/yr |
Siemens
Larsen & Toubro Limited
TCS
Wipro