Filter interviews by
I applied via Company Website and was interviewed in Jul 2024. There were 3 interview rounds.
Different types of control loops include open loop, closed loop, and feedback control loops. Communication protocols include Modbus, Profibus, and HART.
Open loop control: Input signal directly controls the process without feedback.
Closed loop control: Feedback is used to adjust the process based on the output.
Feedback control loop: Compares the actual output with the desired setpoint and adjusts the process accordingly...
I have worked on various projects in my current company, including designing a new software system and implementing a new automation process.
Designed a new software system to improve efficiency in data management
Implemented a new automation process to streamline production
Collaborated with cross-functional teams to ensure project success
Seeking new challenges and opportunities for growth.
Looking for new challenges and opportunities for professional growth
Interested in exploring different industries or technologies
Seeking a company with better work-life balance or benefits
Current company may not align with long-term career goals
I am impressed by your innovative projects and strong commitment to excellence.
I admire the cutting-edge technology your organization is known for
I am excited about the opportunity to work with a talented team of engineers
Your company's reputation for quality and innovation aligns with my career goals
I applied via Recruitment Consulltant and was interviewed before May 2021. There was 1 interview round.
posted on 23 Feb 2024
Chiller and VRF systems differ in their cooling capacity, efficiency, and cost.
Chillers are better suited for large commercial buildings with high cooling loads.
VRF systems are more efficient and cost-effective for smaller buildings or individual rooms.
Chillers use water as a cooling medium, while VRF systems use refrigerant.
Chillers require more maintenance and have a longer lifespan than VRF systems.
VRF systems offer...
I applied via Referral and was interviewed before Jun 2022. There were 5 interview rounds.
I applied via Company Website and was interviewed before Jun 2023. There was 1 interview round.
Major resistance by old method involves using traditional techniques to determine the level of resistance in a material.
Use manual testing methods such as scratch testing or hardness testing to assess resistance
Refer to historical data or records of similar materials for comparison
Consult with experienced professionals who have knowledge of traditional resistance testing methods
I applied via Newspaper Ad and was interviewed before Mar 2022. There were 2 interview rounds.
Normal aptitude questions were asked.
I applied via Company Website and was interviewed in Oct 2022. There were 2 interview rounds.
I was previously working as a Software Engineer at XYZ Company.
Developed and maintained software applications
Collaborated with cross-functional teams to gather requirements and design solutions
Implemented new features and enhancements
Performed code reviews and debugging
Participated in agile development processes
I am familiar with a wide range of test equipment including oscilloscopes, multimeters, signal generators, and power supplies.
Oscilloscopes: Tektronix TDS2024B, Agilent DSO-X 2002A
Multimeters: Fluke 87V, Keysight U1253B
Signal generators: Tektronix AFG3102, Agilent 33220A
Power supplies: Agilent E3631A, Tektronix PS2520G
I have a systematic approach to fault rectification, starting with identifying the root cause and then implementing a solution.
I begin by gathering information about the problem and analyzing it thoroughly
I then identify the root cause of the issue and prioritize the most critical problems
I develop a plan of action and implement a solution, testing it thoroughly to ensure it is effective
I document the entire process fo...
Our system operates on the 2.4 GHz frequency band.
Our system uses the 2.4 GHz frequency band for communication.
This frequency band is commonly used for Wi-Fi and Bluetooth devices.
It has a range of approximately 30 meters indoors.
The 2.4 GHz band is susceptible to interference from other devices operating on the same frequency.
Our system has been optimized to minimize interference and ensure reliable communication.
Yes, I am ready to travel frequently to different locations within India.
I have a flexible schedule and am willing to travel as required.
I have previous experience traveling for work.
I understand the importance of being adaptable and open to new locations.
I am familiar with the travel logistics within India.
I am excited about the opportunity to explore different parts of the country.
based on 2 interviews
Interview experience
based on 1 review
Rating in categories
Senior Engineer
57
salaries
| ₹0 L/yr - ₹0 L/yr |
Design Engineer
49
salaries
| ₹0 L/yr - ₹0 L/yr |
Technical Lead
40
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Software Engineer
36
salaries
| ₹0 L/yr - ₹0 L/yr |
System Engineer
34
salaries
| ₹0 L/yr - ₹0 L/yr |
Johnson Controls
Carrier
Daikin
Trane Technologies