Transformers are rated in kVA because it represents the apparent power capacity of the transformer.
kVA is a unit of apparent power, which takes into account both the real power (kW) and reactive power (kVAR) of the transformer.
The kVA rating helps in determining the maximum load that a transformer can handle without overheating or overloading.
It is important to specify the kVA rating of a transformer to ensure compatib...
Magnetic balancing of a transformer involves adjusting the magnetic flux to ensure proper operation and efficiency.
Magnetic balancing is necessary to prevent overheating and ensure optimal performance of the transformer.
This process involves adjusting the turns ratio of the transformer windings to achieve the desired magnetic flux.
Proper magnetic balancing helps in reducing losses and improving the efficiency of the tr...
Testing of circuit breakers involves checking for proper functionality and safety measures.
Performing visual inspections for any signs of damage or wear
Testing the circuit breaker with a multimeter to ensure proper voltage and current readings
Tripping the circuit breaker manually to test its response time
Checking for proper grounding and connections
Conducting insulation resistance tests to ensure safety
Regular maintena
Land and property Acquisition
I applied via Walk-in
I applied via Naukri.com and was interviewed in Dec 2021. There were 4 interview rounds.
Land and property Acquisition
I was interviewed before Feb 2021.
I applied via Naukri.com and was interviewed in May 2021. There was 1 interview round.
I applied via Walk-in and was interviewed before May 2020. There were 5 interview rounds.
The size of wire required for j500 tone chiller depends on the voltage and amperage of the chiller.
The wire size should be determined based on the voltage and amperage of the chiller.
The National Electrical Code (NEC) provides guidelines for selecting the appropriate wire size.
The wire size should be able to handle the maximum current that the chiller will draw.
A larger wire size may be required for longer wire runs or...
based on 3 interviews
Interview experience
based on 8 reviews
Rating in categories
Assistant Manager
1.6k
salaries
| ₹3.8 L/yr - ₹10.9 L/yr |
Facility Executive
629
salaries
| ₹2.2 L/yr - ₹6.3 L/yr |
Assistant Facility Manager
514
salaries
| ₹3.5 L/yr - ₹10.2 L/yr |
Facility Manager
496
salaries
| ₹5 L/yr - ₹14.4 L/yr |
Deputy Manager
485
salaries
| ₹4.1 L/yr - ₹13 L/yr |
JLL
Colliers India
Knight Frank
Cushman & Wakefield