i
Atlas Copco
Filter interviews by
I appeared for an interview in Sep 2024, where I was asked the following questions.
I applied via LinkedIn and was interviewed in Mar 2024. There was 1 interview round.
Top trending discussions
I have worked on various DCS architectures in my career, including those for chemical plants and power plants.
Designed and implemented DCS architecture for a chemical plant project
Developed DCS architecture for a power plant project
Worked on DCS architecture for a water treatment plant project
Collaborated with team to create DCS architecture for a pharmaceutical plant project
What is relay..who it's work what is conductor tell about plc,scada,hmi
I applied via Naukri.com and was interviewed in Mar 2023. There were 2 interview rounds.
Environment conditions such as temperature, humidity, and cleanliness are crucial for panel installation.
Temperature should be within specified range to prevent damage to components.
Humidity levels should be controlled to avoid condensation and corrosion.
Cleanliness is important to prevent dust and debris from affecting performance.
Proper ventilation is necessary to prevent overheating.
Avoid exposure to direct sunlight...
Restricted Earth Fault is a type of fault in electrical systems where the fault current is limited to a specific section of the system.
Occurs when a fault current flows from a phase conductor to the earth through a restricted path
Usually detected by a relay that monitors the current imbalance between the phase and neutral conductors
Helps in quickly identifying and isolating the fault to prevent damage to equipment and ...
Differential earth fault is a type of fault in electrical systems where the current flowing into and out of the system is not equal due to an earth fault.
Differential earth fault protection is used to detect such faults by comparing the current entering and leaving the system.
It is important for safety as it helps prevent damage to equipment and potential electric shocks.
Examples of differential earth fault protection ...
Transformer insulation class indicates the temperature at which the insulation can operate safely.
Transformer insulation class is denoted by a letter (e.g. A, B, F, H) which corresponds to a maximum allowable temperature rise above ambient.
Higher insulation classes can withstand higher temperatures, providing better protection for the transformer.
Common insulation classes include A (105°C), B (130°C), F (155°C), and H
Implement a scheme using temperature sensors to detect transformer temperature.
Install temperature sensors at key points on the transformer
Set up a monitoring system to continuously track temperature readings
Establish temperature thresholds for alerts and shutdowns
Implement a cooling system to regulate temperature if needed
Voltage levels as per standards vary depending on the application and region, with common levels including 110V, 220V, and 415V.
Voltage levels can vary depending on the application and region
Common residential voltage levels include 110V and 220V
Industrial voltage levels are typically higher, such as 415V
International standards like IEC and ANSI provide guidelines for voltage levels
Molded Case Circuit Breakers (MCCBs) are types of circuit breakers that provide protection against overcurrents.
Thermal-magnetic MCCB: Trips when a current overload or short circuit is detected.
Electronic MCCB: Uses electronic components for more precise and adjustable protection.
Compact MCCB: Smaller in size for limited space installations.
Adjustable MCCB: Allows for manual adjustment of trip settings.
Motor protection...
Factors to consider for lighting calculation include type of space, desired lighting levels, fixture efficiency, and lighting layout.
Type of space (office, warehouse, retail, etc.)
Desired lighting levels (measured in lux or foot-candles)
Fixture efficiency (lumens per watt)
Lighting layout (spacing and placement of fixtures)
Natural lighting sources (windows, skylights)
Color rendering index (CRI) for accurate color repres...
I applied via Recruitment Consulltant and was interviewed before Apr 2023. There was 1 interview round.
What is the meaning of NPSH?
I applied via Company Website and was interviewed in May 2024. There were 2 interview rounds.
Communication between PLC controllers and DCS involves establishing a reliable connection for data exchange.
PLC controllers and DCS communicate through various communication protocols such as Modbus, Profibus, Ethernet/IP, etc.
Data is exchanged between PLC controllers and DCS for process control and monitoring.
Communication can be bidirectional, allowing both systems to send and receive data.
Proper configuration and pr...
I applied via Naukri.com and was interviewed in May 2024. There was 1 interview round.
Temperature and irradiance affect the performance and efficiency of solar panels.
High temperatures can decrease the efficiency of solar panels.
Increased irradiance levels can lead to higher power output.
Temperature coefficient determines the panel's performance at different temperatures.
Irradiance levels vary based on factors like time of day, weather conditions, and panel orientation.
Temperature and irradiance should
Co-generation plants produce both electricity and heat. They can be linked with solar PV plants to increase energy efficiency.
Co-generation plants use a single fuel source to produce both electricity and heat
Solar PV plants generate electricity from sunlight
Linking co-generation plants with solar PV plants can increase overall energy efficiency
Excess heat from co-generation plants can be used to power solar thermal sys...
based on 2 interviews
Interview experience
based on 17 reviews
Rating in categories
Design Engineer
282
salaries
| ₹2.4 L/yr - ₹12 L/yr |
Service Engineer
225
salaries
| ₹1.8 L/yr - ₹10 L/yr |
Senior Design Engineer
206
salaries
| ₹5.8 L/yr - ₹15.5 L/yr |
Project Engineer
182
salaries
| ₹6 L/yr - ₹17 L/yr |
Senior Service Engineer
104
salaries
| ₹4.5 L/yr - ₹14 L/yr |
John Deere
Cummins
ABB
Tractors and Farm Equipment