Fire alarm systems are designed to detect and alert people about the presence of fire or smoke in a building.
Fire alarm systems consist of various components such as smoke detectors, heat detectors, fire alarm control panels, and notification devices.
Smoke detectors are designed to sense the presence of smoke particles in the air and trigger an alarm.
Heat detectors are used to detect rapid increases in temperature and ...
FM 200 systems are fire suppression systems that use HFC-227ea as the extinguishing agent.
FM 200 systems are commonly used in areas where water-based fire suppression systems are not suitable, such as data centers and museums.
HFC-227ea is a clean agent that does not leave residue or damage sensitive equipment.
FM 200 systems work by reducing the oxygen concentration in the protected area to a level that cannot support c...
A fire alarm is a system that detects and alerts people to the presence of fire, allowing for timely evacuation and fire suppression.
Fire alarms work by detecting smoke, heat, or flames using sensors.
When the sensors detect a potential fire, they send a signal to the control panel.
The control panel then activates the alarm devices, such as sirens, strobe lights, and voice evacuation systems.
Fire alarms may also be conn...
FM 200 is a clean agent fire suppression system commonly used in data centers and other sensitive areas.
FM 200 is a colorless, odorless gas that is stored in cylinders.
When discharged, FM 200 quickly fills the protected area and suppresses the fire by removing heat.
It works by interrupting the chemical chain reaction of the fire.
FM 200 is non-toxic and safe for occupied spaces.
After discharge, FM 200 dissipates into th...
Yes, FM-200 removes oxygen.
FM-200 is a clean agent fire suppression system that works by removing oxygen from the fire.
It chemically reacts with the fire to interrupt the combustion process.
By reducing the oxygen concentration below the level required to sustain combustion, FM-200 effectively extinguishes the fire.
FM-200 is commonly used in areas where water-based fire suppression systems are not suitable, such as data
FM-200 extinguishes fire by removing heat and interrupting the chemical reaction.
FM-200 is a clean agent fire suppression system.
It works by releasing a colorless and odorless gas into the protected area.
The gas removes heat from the fire, lowering the temperature below the ignition point.
FM-200 also interrupts the chemical reaction of the fire, preventing it from spreading.
It does not leave any residue or damage to th...
FM-200 replaced Halon as a fire suppression agent.
FM-200 is a clean, colorless, and environmentally friendly fire suppression agent.
It is commonly used in areas where water-based fire suppression systems are not suitable.
FM-200 replaced Halon due to its harmful effects on the ozone layer.
Halon was widely used as a fire suppression agent but was phased out due to its ozone-depleting properties.
FM-200 is non-toxic and le...
I applied via Campus Placement and was interviewed before Jan 2020. There were 4 interview rounds.
I applied via Campus Placement and was interviewed before May 2020. There were 4 interview rounds.
I applied via Campus Placement and was interviewed before Feb 2020. There were 4 interview rounds.
I applied via Campus Placement and was interviewed before Jul 2020. There were 4 interview rounds.
The project involved designing and implementing a new network infrastructure for a large corporation.
Conducted a thorough analysis of the existing network infrastructure
Designed a new network architecture that met the company's needs
Implemented the new network infrastructure with minimal disruption to business operations
Tested and optimized the new network to ensure optimal performance
Provided ongoing support and maint
I applied via Walk-in and was interviewed before Feb 2020. There were 4 interview rounds.
I applied via Campus Placement and was interviewed before Feb 2020. There was 1 interview round.
I applied via Recruitment Consultant and was interviewed before Aug 2020. There was 1 interview round.
I applied via Campus Placement and was interviewed before Jun 2020. There were 3 interview rounds.
based on 1 interview
Interview experience
based on 5 reviews
Rating in categories
TCS
Accenture
Wipro
Cognizant