I applied via Recruitment Consultant and was interviewed in Apr 2020. There was 1 interview round.
The existing electrical network refers to the current system of electrical infrastructure in place.
The existing electrical network includes power generation, transmission, and distribution systems.
It may also include electrical equipment and devices such as transformers, switchgear, and meters.
The network may be owned and operated by a utility company or other entity.
The network may have limitations or challenges such ...
Motor and transformer protection schemes are used to prevent damage to the equipment and ensure safe operation.
Motor protection schemes include overload protection, short circuit protection, and earth fault protection.
Transformer protection schemes include overcurrent protection, differential protection, and earth fault protection.
Motor and transformer protection schemes can be achieved through the use of fuses, circui...
Transformer oil tests include dielectric strength, acidity, interfacial tension, and dissolved gas analysis.
Dielectric strength test measures the ability of oil to withstand electrical stress
Acidity test determines the acidity level of oil
Interfacial tension test measures the oil's ability to separate from water
Dissolved gas analysis identifies the presence of gases in the oil, indicating potential faults in the transf...
Reverse synchronisation relay is a protective relay used to prevent the generator from being synchronized with the grid in the wrong direction.
It is used to prevent the generator from being synchronized with the grid in the wrong direction
It detects the reverse power flow from the grid to the generator
It trips the generator breaker if the reverse power flow exceeds a certain limit
It is important for the safety of the g
DG stands for Diesel Generator. It is used as a backup power source in case of power outages or emergencies.
DG is connected to the existing electrical network through an Automatic Transfer Switch (ATS)
The ATS detects when there is a power outage and automatically switches the power source from the main grid to the DG
Once the main power is restored, the ATS switches the power source back to the grid and the DG is turned...
posted on 7 Jul 2023
I applied via Recruitment Consulltant and was interviewed in Jun 2023. There were 3 interview rounds.
posted on 3 Feb 2024
I was interviewed in Jan 2024.
posted on 1 May 2024
I applied via Walk-in and was interviewed before May 2023. There was 1 interview round.
Transformers work on the principle of electromagnetic induction to transfer electrical energy between two or more circuits.
Transformers have two coils of wire, known as primary and secondary coils, which are wound around a core made of ferromagnetic material.
When an alternating current flows through the primary coil, it creates a changing magnetic field around the coil.
This changing magnetic field induces a voltage in ...
Transformers are cooled using methods such as oil cooling, air cooling, and water cooling.
Oil cooling: Transformers are immersed in oil to dissipate heat generated during operation.
Air cooling: Fans are used to circulate air around the transformer to cool it down.
Water cooling: Water is circulated around the transformer to absorb heat and cool it.
Forced oil cooling: Oil is circulated through a heat exchanger to remove
posted on 8 Aug 2022
posted on 23 Sep 2023
I applied via Referral and was interviewed before Sep 2022. There were 3 interview rounds.
posted on 20 Aug 2021
I applied via Naukri.com and was interviewed in Jul 2021. There were 3 interview rounds.
Current is the flow of electric charge in a circuit.
Current is measured in amperes (A).
It is caused by the movement of electrons or other charged particles.
Current can flow in both directions in an alternating current (AC) circuit.
In a direct current (DC) circuit, current flows in only one direction.
Current is essential for the operation of electrical devices and systems.
Examples of current include the flow of electric...
posted on 27 Dec 2021
I applied via Naukri.com and was interviewed before Dec 2020. There was 1 interview round.
posted on 13 May 2018
based on 1 review
Rating in categories
Assistant Manager
583
salaries
| ₹4.5 L/yr - ₹12.8 L/yr |
Deputy Manager
572
salaries
| ₹6.7 L/yr - ₹17.5 L/yr |
Executive
567
salaries
| ₹2.5 L/yr - ₹7.7 L/yr |
Plant Operator
329
salaries
| ₹1.6 L/yr - ₹4.8 L/yr |
Senior Executive
322
salaries
| ₹3.3 L/yr - ₹9 L/yr |
Vinati Organics
Atul
Navin Fluorine International
Solvay Specialities