Filter interviews by
I applied via Recruitment Consulltant and was interviewed in Jul 2021. There were 2 interview rounds.
Top trending discussions
I applied via Walk-in and was interviewed in Sep 2024. There was 1 interview round.
I applied via Walk-in and was interviewed in May 2022. There were 2 interview rounds.
Given a technical problem, solve it in minimum time.
Identify the problem and its root cause
Brainstorm possible solutions
Choose the most efficient solution
Implement the solution quickly and accurately
I applied via Walk-in and was interviewed in Oct 2023. There were 3 interview rounds.
I applied via Campus Placement and was interviewed in Nov 2021. There were 4 interview rounds.
I applied via Campus Placement and was interviewed before Oct 2020. There were 4 interview rounds.
Series reactors are used in transmission lines to limit the flow of current and improve system stability.
Series reactors are used to limit the flow of current in a transmission line.
They improve system stability by reducing voltage fluctuations and power surges.
They can also be used to compensate for line capacitance and improve power factor.
Examples of series reactors include air-core reactors, iron-core reactors, and...
Yes, core loss depends upon frequency.
Core loss is the energy lost in the magnetic core of a transformer or inductor.
It is caused by hysteresis and eddy current losses.
Hysteresis loss is proportional to the frequency and magnetic flux density.
Eddy current loss is proportional to the square of the frequency and the thickness of the core.
Higher frequency leads to higher core loss, which can cause overheating and reduced
I applied via Recruitment Consultant and was interviewed in Mar 2021. There were 3 interview rounds.
I applied via Approached by Company and was interviewed before May 2022. There were 2 interview rounds.
The 3 tier breaker interlock scheme is used to ensure safe and efficient power distribution from different sources.
The scheme involves three levels of protection to prevent power overload and equipment damage.
The first tier involves interlocking the main breaker with the emergency stop button to quickly shut off power in case of an emergency.
The second tier involves interlocking the main breaker with the VFD and starte...
based on 2 interviews
Interview experience
based on 7 reviews
Rating in categories
Production Supervisor
689
salaries
| ₹1.8 L/yr - ₹9 L/yr |
Executive
256
salaries
| ₹3 L/yr - ₹10.6 L/yr |
Supervisor
241
salaries
| ₹2.2 L/yr - ₹8.5 L/yr |
Research Scientist
214
salaries
| ₹4 L/yr - ₹11 L/yr |
Senior Executive
162
salaries
| ₹6.1 L/yr - ₹14.6 L/yr |
Aarti Industries
UPL
Coromandel International
Rallis India