Filter interviews by
I applied via Approached by Company and was interviewed before May 2022. There were 2 interview rounds.
The 3 tier breaker interlock scheme is used to ensure safe and efficient power distribution from different sources.
The scheme involves three levels of protection to prevent power overload and equipment damage.
The first tier involves interlocking the main breaker with the emergency stop button to quickly shut off power in case of an emergency.
The second tier involves interlocking the main breaker with the VFD and starte...
I applied via Campus Placement and was interviewed in Nov 2021. There were 4 interview rounds.
I applied via Recruitment Consultant and was interviewed in Mar 2021. There were 3 interview rounds.
I applied via Campus Placement and was interviewed before Oct 2020. There were 4 interview rounds.
Series reactors are used in transmission lines to limit the flow of current and improve system stability.
Series reactors are used to limit the flow of current in a transmission line.
They improve system stability by reducing voltage fluctuations and power surges.
They can also be used to compensate for line capacitance and improve power factor.
Examples of series reactors include air-core reactors, iron-core reactors, and...
Yes, core loss depends upon frequency.
Core loss is the energy lost in the magnetic core of a transformer or inductor.
It is caused by hysteresis and eddy current losses.
Hysteresis loss is proportional to the frequency and magnetic flux density.
Eddy current loss is proportional to the square of the frequency and the thickness of the core.
Higher frequency leads to higher core loss, which can cause overheating and reduced
Aarti Industries interview questions for designations
Top trending discussions
posted on 7 Jul 2023
I applied via Recruitment Consulltant and was interviewed in Jun 2023. There were 3 interview rounds.
I applied via Recruitment Consultant and was interviewed in May 2021. There were 3 interview rounds.
posted on 27 Dec 2021
I applied via Naukri.com and was interviewed before Dec 2020. There was 1 interview round.
I applied via Referral and was interviewed in Apr 2021. There were 3 interview rounds.
Relay coordination principle ensures that the protective devices operate in a coordinated manner to isolate the faulted section.
Relay coordination principle is used to ensure that the protective devices operate in a coordinated manner to isolate the faulted section.
It involves selecting the appropriate time-current characteristic curves for the protective devices.
The aim is to ensure that the protective device closest ...
TG protection details with rated setting
TG protection refers to transformer generator protection
Rated setting refers to the maximum allowable current or voltage that the protection system can handle
The protection system should be able to detect and isolate faults in the TG system
The rated setting should be set based on the maximum expected fault current or voltage
The protection system should be regularly tested and mai
NGR function with auto operation
NGR stands for Neutral Grounding Resistor
It is used to limit the fault current in a power system
Auto operation means the NGR is automatically switched on or off based on the system conditions
This helps in protecting the equipment and personnel from damage or harm
Daily maintenance planning schedule involves scheduling and prioritizing maintenance tasks.
Create a list of maintenance tasks
Prioritize tasks based on urgency and importance
Assign tasks to team members
Set deadlines for completion
Regularly review and adjust schedule as needed
I applied via Approached by Company and was interviewed before Sep 2022. There were 4 interview rounds.
posted on 18 Jun 2024
I applied via Naukri.com and was interviewed before Jun 2023. There were 2 interview rounds.
About work experience
Some of the top questions asked at the Aarti Industries Electrical Engineer interview -
based on 1 interview
2 Interview rounds
based on 17 reviews
Rating in categories
Assistant Manager
600
salaries
| ₹4.5 L/yr - ₹12.8 L/yr |
Deputy Manager
584
salaries
| ₹6.7 L/yr - ₹16 L/yr |
Executive
515
salaries
| ₹2.4 L/yr - ₹7.7 L/yr |
Senior Executive
344
salaries
| ₹3.3 L/yr - ₹10.3 L/yr |
Plant Operator
344
salaries
| ₹1.6 L/yr - ₹5.2 L/yr |
UPL
Coromandel International
PI Industries
Deccan Fine Chemicals