I applied via Naukri.com and was interviewed in Jul 2021. There were 3 interview rounds.
Current is the flow of electric charge in a circuit.
Current is measured in amperes (A).
It is caused by the movement of electrons or other charged particles.
Current can flow in both directions in an alternating current (AC) circuit.
In a direct current (DC) circuit, current flows in only one direction.
Current is essential for the operation of electrical devices and systems.
Examples of current include the flow of electric...
I applied via Campus Placement and was interviewed before Oct 2020. There were 4 interview rounds.
Series reactors are used in transmission lines to limit the flow of current and improve system stability.
Series reactors are used to limit the flow of current in a transmission line.
They improve system stability by reducing voltage fluctuations and power surges.
They can also be used to compensate for line capacitance and improve power factor.
Examples of series reactors include air-core reactors, iron-core reactors, and...
Yes, core loss depends upon frequency.
Core loss is the energy lost in the magnetic core of a transformer or inductor.
It is caused by hysteresis and eddy current losses.
Hysteresis loss is proportional to the frequency and magnetic flux density.
Eddy current loss is proportional to the square of the frequency and the thickness of the core.
Higher frequency leads to higher core loss, which can cause overheating and reduced
I applied via Recruitment Consultant and was interviewed in Mar 2021. There were 3 interview rounds.
I applied via Recruitment Consultant and was interviewed before Aug 2020. There was 1 interview round.
I applied via Recruitment Consultant and was interviewed in Jun 2020. There were 3 interview rounds.
posted on 27 Dec 2021
I applied via Naukri.com and was interviewed before Dec 2020. There was 1 interview round.
posted on 7 Jul 2023
I applied via Recruitment Consulltant and was interviewed in Jun 2023. There were 3 interview rounds.
I applied via Company Website and was interviewed in Dec 2023. There were 2 interview rounds.
Technically knowledge
I applied via Approached by Company and was interviewed before May 2022. There were 2 interview rounds.
The 3 tier breaker interlock scheme is used to ensure safe and efficient power distribution from different sources.
The scheme involves three levels of protection to prevent power overload and equipment damage.
The first tier involves interlocking the main breaker with the emergency stop button to quickly shut off power in case of an emergency.
The second tier involves interlocking the main breaker with the VFD and starte...
Retail Store Manager
39
salaries
| ₹2.1 L/yr - ₹3.8 L/yr |
Assistant Manager
26
salaries
| ₹4.2 L/yr - ₹8.2 L/yr |
Officer
14
salaries
| ₹3.1 L/yr - ₹5.5 L/yr |
Senior Officer
11
salaries
| ₹3.8 L/yr - ₹6.5 L/yr |
Marketing Manager
9
salaries
| ₹9.5 L/yr - ₹16.3 L/yr |
Aarti Industries
UPL
Coromandel International
PI Industries