Filter interviews by
I applied via Newspaper Ad and was interviewed in Feb 2022. There were 2 interview rounds.
I appeared for an interview in Jul 2017.
I appeared for an interview before Jan 2021.
Diploma
posted on 18 May 2020
I applied via Naukri.com and was interviewed in Nov 2019. There were 3 interview rounds.
Control valve calibration involves adjusting the valve to ensure it operates within specified parameters.
Determine the valve's operating range and desired set points
Use a calibration bench or in-line calibration equipment to adjust the valve's position and response time
Verify the valve's performance using a flow meter or pressure gauge
Document the calibration process and results for future reference
I applied via Recruitment Consultant and was interviewed in Apr 2020. There were 3 interview rounds.
I applied via Naukri.com and was interviewed in Oct 2020. There were 3 interview rounds.
I applied via From internet and was interviewed in Feb 2021. There was 1 interview round.
I applied via Approached by Company and was interviewed before Apr 2023. There were 2 interview rounds.
No, TIA Portal is not compatible with S7-300 CPU.
TIA Portal is designed for newer Siemens PLCs like S7-1200 and S7-1500, not S7-300.
For S7-300 CPUs, Step 7 software should be used for programming.
TIA Portal offers advanced features like integrated safety, motion control, and HMI design.
S7-300 CPUs are older models with limited capabilities compared to newer PLCs.
Encoder provides digital output while resolver provides analog output.
Encoder converts mechanical motion into digital signals, resolver converts mechanical motion into analog signals.
Encoder is more accurate and provides higher resolution compared to resolver.
Resolver is more robust and reliable in harsh environments due to lack of sensitive electronics.
Examples: Encoder - optical encoder, magnetic encoder. Resolver -
Pressure relief valve releases excess pressure to prevent damage, while pressure reducing valve reduces pressure to a desired level.
Pressure relief valve is used to protect equipment from overpressure by releasing excess pressure to the atmosphere.
Pressure reducing valve is used to reduce the pressure of a fluid to a desired level in a system.
Pressure relief valves are typically found in systems where pressure buildup ...
Hydraulic piston pumps offer higher efficiency, variable flow rates, and better control compared to fixed displacement vane pumps.
Hydraulic piston pumps have higher efficiency due to their ability to vary flow rates based on demand, reducing energy consumption.
Piston pumps provide better control over fluid flow and pressure, making them suitable for applications requiring precise operation.
Piston pumps are more durable...
Assistant Engineer
198
salaries
| ₹1.8 L/yr - ₹4.6 L/yr |
Production Engineer
154
salaries
| ₹1.8 L/yr - ₹6 L/yr |
Assistant Manager
130
salaries
| ₹4.2 L/yr - ₹13 L/yr |
Senior Engineer
113
salaries
| ₹3 L/yr - ₹8.2 L/yr |
Engineer
109
salaries
| ₹2.2 L/yr - ₹6.6 L/yr |
Tata Steel
JSW Steel
Jindal Steel and Power
ArcelorMittal Nippon Steel