Filter interviews by
Electrical symbols are graphical representations of electrical components and devices used in circuit diagrams.
Electrical symbols are used to depict various electrical components such as resistors, capacitors, switches, and transformers.
These symbols provide a standardized way of representing electrical elements in circuit diagrams.
They help in understanding and interpreting electrical circuits and systems.
Examples of ...
Top trending discussions
posted on 15 Apr 2022
I was interviewed in Oct 2021.
posted on 23 Feb 2021
I applied via Campus Placement and was interviewed in Jan 2021. There was 1 interview round.
posted on 29 Aug 2023
posted on 5 Sep 2023
I applied via Walk-in and was interviewed in Aug 2023. There were 2 interview rounds.
An ideal transformer is a theoretical transformer with no losses and perfect efficiency.
An ideal transformer has no resistance, leakage inductance, or core losses.
It has a turns ratio that perfectly converts voltage and current from primary to secondary windings.
Efficiency is 100% in an ideal transformer.
Real transformers have losses due to resistance, eddy currents, and hysteresis.
kVA is the apparent power, while kW is the real power. The relationship between them is determined by the power factor.
kVA is the product of voltage and current in a circuit, while kW is the actual power consumed by the load.
The relationship between kVA and kW is determined by the power factor of the load.
Power factor = kW / kVA. A power factor of 1 indicates all power is being used efficiently.
For example, if a load h...
posted on 23 Feb 2023
I applied via Approached by Company and was interviewed in Aug 2022. There were 2 interview rounds.
Electrical safety is crucial for maintenance work to prevent accidents and injuries.
Proper training and education on electrical safety measures
Use of personal protective equipment (PPE) such as gloves, goggles, and insulated tools
Regular inspection and maintenance of electrical equipment
Adherence to safety regulations and guidelines
Proper labeling and identification of electrical hazards
Emergency response plan in case ...
Electrical maintenance servicing for power factor 0.999
Power factor correction capacitor maintenance
Regular inspection of electrical equipment
Testing and calibration of power factor meters
Monitoring and analysis of power factor data
Implementation of energy-efficient measures
posted on 21 Sep 2022
Maintenance and assembly are crucial for ensuring equipment reliability and optimal performance.
Maintenance involves regular inspections, cleaning, lubrication, and replacement of worn-out parts to prevent breakdowns and extend equipment lifespan.
Assembly involves putting together components to create a functional system or machine.
Both maintenance and assembly require technical knowledge, attention to detail, and adhe...
I applied via Naukri.com and was interviewed in Apr 2022. There were 2 interview rounds.
I applied via Campus Placement and was interviewed in Feb 2022. There were 2 interview rounds.
posted on 26 May 2022
I applied via Walk-in and was interviewed in Apr 2022. There were 2 interview rounds.
based on 1 review
Rating in categories
Junior Manager
1.5k
salaries
| ₹2 L/yr - ₹8.3 L/yr |
Deputy Manager
1.3k
salaries
| ₹5 L/yr - ₹20 L/yr |
Assistant Manager
872
salaries
| ₹3.8 L/yr - ₹10.6 L/yr |
Channel Sales Manager
246
salaries
| ₹6 L/yr - ₹17.8 L/yr |
Manager
242
salaries
| ₹10 L/yr - ₹26 L/yr |
Tata Motors
Ashok Leyland
Mahindra & Mahindra
Eicher Motors