i
Tata Projects
Proud winner of ABECA 2024 - AmbitionBox Employee Choice Awards
Filter interviews by
I applied via Walk-in and was interviewed in Aug 2024. There was 1 interview round.
Diesel generator is a backup power source using diesel fuel, transformer is a device that transfers electrical energy between circuits, and HVAC is a system for heating, ventilation, and air conditioning.
Diesel generator: provides backup power using diesel fuel, commonly used in areas with frequent power outages
Transformer: transfers electrical energy between circuits, stepping up or down voltage levels as needed
HVAC: ...
A fire fighting system is a set of equipment and procedures designed to detect, control, and extinguish fires in a building or area.
Includes fire alarms, sprinkler systems, fire extinguishers, and fire hoses
May also involve fire suppression systems like foam or gas
Designed to protect lives and property in the event of a fire
Regular maintenance and testing are crucial to ensure effectiveness
DM plant stands for Demineralization plant, used to remove minerals and salts from water.
DM plant is used in industries to produce demineralized water for various processes.
It consists of ion exchange resins to remove minerals like calcium, magnesium, and salts from water.
The process involves passing water through cation and anion exchange columns to remove ions.
DM plant is essential in power plants, pharmaceutical ind...
ACB, VCB, MCCB, MCB are types of circuit breakers used in electrical systems.
ACB stands for Air Circuit Breaker, used for high voltage applications.
VCB stands for Vacuum Circuit Breaker, used for medium voltage applications.
MCCB stands for Molded Case Circuit Breaker, used for low voltage applications.
MCB stands for Miniature Circuit Breaker, used for residential and commercial applications.
I was interviewed in Feb 2023.
Top trending discussions
posted on 20 Nov 2024
I applied via Company Website and was interviewed in Oct 2024. There were 2 interview rounds.
C6h12o6 what's this is
Auxin is a plant hormone that regulates growth and development.
Auxin is responsible for cell elongation and division in plants.
It plays a role in phototropism, gravitropism, and apical dominance.
Examples of auxin include indole-3-acetic acid (IAA) and synthetic auxins like 2,4-D.
posted on 3 Oct 2024
The erection of an 11 kV line involves setting up a power line infrastructure for transmitting electricity over a distance of 1 km.
Materials required include conductors (such as aluminum or copper), insulators, poles, transformers, and hardware fittings.
The conductors are used to carry the electricity from one point to another, while insulators prevent the flow of electricity to the ground.
Poles are used to support the...
posted on 3 May 2024
I applied via Approached by Company and was interviewed before May 2023. There were 2 interview rounds.
posted on 28 Dec 2022
I applied via Naukri.com and was interviewed in Jun 2022. There were 2 interview rounds.
ATS stands for Automatic Transfer Switch. It is used to transfer power supply between two sources. Transformer and motor maintenance procedures and protection methods are essential for their efficient operation. SAP is a software used for enterprise resource planning.
ATS is used to automatically switch power supply between two sources, ensuring uninterrupted power supply.
Transformer maintenance involves regular inspect...
HT motor rating is the maximum power it can handle and FLC is the current it draws at full load.
HT motor rating is expressed in kilowatts (kW) or megawatts (MW).
FLC of HT motor is the full load current it draws at rated voltage and frequency.
FLC is expressed in amperes (A) and varies depending on the motor's power rating and efficiency.
For example, a 1 MW HT motor may have a FLC of 1000 A at 11 kV.
The rating and FLC of...
Plant EHT system and single line diagram of plants.
EHT system refers to Extra High Tension system used in power plants
Single line diagram shows the electrical connections between different components
It is important to have a clear and accurate diagram for safety and maintenance purposes
posted on 11 Feb 2024
I was interviewed before Feb 2023.
The major parts in a power transformer include the core, windings, insulation, cooling system, and tap changer.
Core: Provides a path for magnetic flux and is usually made of laminated steel sheets.
Windings: Consist of primary and secondary coils that transfer electrical energy.
Insulation: Prevents electrical leakage and ensures safety.
Cooling System: Keeps the transformer within operating temperature limits, commonly u...
I want to switch electrical circuits and devices.
Switching electrical circuits to control the flow of electricity.
Switching electrical devices on or off.
Switching between different power sources.
Switching between different modes or settings of electrical equipment.
Switching between different electrical connections or configurations.
posted on 20 Apr 2021
I applied via Naukri.com and was interviewed in Mar 2021. There was 1 interview round.
based on 36 reviews
Rating in categories
Deputy Manager
1.1k
salaries
| ₹5.7 L/yr - ₹17 L/yr |
Assistant Manager
706
salaries
| ₹5 L/yr - ₹14.8 L/yr |
Manager
387
salaries
| ₹8 L/yr - ₹24.1 L/yr |
Senior Engineer
373
salaries
| ₹3.5 L/yr - ₹13 L/yr |
Senior Manager
315
salaries
| ₹10.4 L/yr - ₹32.5 L/yr |
Larsen & Toubro Limited
Reliance Infrastructure
GMR Group
Hindustan Construction Company