Filter interviews by
To find out a worn bearing number, inspect the bearing for visible signs of wear and refer to the bearing manufacturer's documentation.
Inspect the bearing for signs of wear such as discoloration, pitting, or scoring on the bearing surface.
Check for excessive play or looseness in the bearing when it is rotated.
Refer to the bearing manufacturer's documentation or catalog to identify the bearing number based on its physic...
Seal numbers can be found on the seal itself or in the equipment manual.
Check the seal itself for any visible numbers or markings.
Refer to the equipment manual for information on the seal.
Contact the manufacturer or supplier for assistance in identifying the seal number.
Types of pumps include centrifugal, positive displacement, axial flow, and jet pumps.
Centrifugal pumps use a rotating impeller to create a flow of fluid.
Positive displacement pumps move fluid by trapping a fixed amount and forcing it through the system.
Axial flow pumps move fluid parallel to the axis of rotation.
Jet pumps use a jet of high-pressure fluid to create a low-pressure area and move fluid.
Other types of pumps...
Gear boxes are used to transmit power and torque from one rotating shaft to another. There are several types of gear boxes.
Manual transmission
Automatic transmission
Semi-automatic transmission
Continuously variable transmission (CVT)
Dual-clutch transmission (DCT)
Epicyclic gear train
Planetary gear train
Worm gear box
Bevel gear box
Helical gear box
Pumps can be classified based on their working principle, design, and application.
Based on working principle: centrifugal, positive displacement, and jet pumps
Based on design: single-stage, multi-stage, axial, and mixed flow pumps
Based on application: water, chemical, slurry, and oil pumps
Other classifications: reciprocating, rotary, and diaphragm pumps
Mechanical seals are used to prevent leakage in rotating equipment. They can be classified into various types based on their design and application.
Types of mechanical seals include pusher seals, non-pusher seals, cartridge seals, and split seals.
Pusher seals use springs to maintain contact between the seal faces.
Non-pusher seals rely on the pressure of the fluid being sealed to maintain contact.
Cartridge seals are pre...
Maintenance of compressors involves regular inspection, cleaning, lubrication, and replacement of worn-out parts.
Regular inspection of compressor components such as valves, pistons, and bearings
Cleaning of air filters, coolers, and intercoolers to prevent clogging
Lubrication of moving parts to reduce friction and wear
Replacement of worn-out parts such as belts, hoses, and seals
Monitoring of compressor performance and a
Pneumatic cylinders use compressed air while hydraulic cylinders use pressurized fluid to generate force.
Pneumatic cylinders are lighter and cheaper than hydraulic cylinders.
Hydraulic cylinders can generate more force than pneumatic cylinders.
Single-acting, double-acting, and telescoping are common types of hydraulic cylinders.
Diaphragm, bellows, and rodless are common types of pneumatic cylinders.
Solenoid valves are used to control the flow of fluids or gases in mechanical systems.
Solenoid valves are commonly used in hydraulic and pneumatic systems.
They can be used to control the flow of water, oil, gas, or air.
They are often used in HVAC systems to control the flow of refrigerant.
Solenoid valves can be controlled by electrical signals to open or close the valve.
They are also used in automatic irrigation system...
There are various types of oils used in mechanical maintenance, each with different grades and purposes.
Mineral oils: Derived from crude oil and commonly used in engines and machinery.
Synthetic oils: Man-made oils with superior performance and stability, often used in high-performance engines.
Semi-synthetic oils: Blend of mineral and synthetic oils, offering a balance between performance and cost.
Multi-grade oils: Desi...
A torque spanner is a tool used to apply a specific amount of torque to fasteners.
A torque spanner is also known as a torque wrench.
It is commonly used in mechanical maintenance to ensure proper tightening of bolts and nuts.
Torque spanners have a calibrated scale or digital display to set the desired torque value.
They provide a clicking sound or visual indicator when the set torque is reached.
Different types of torque ...
Alignment of pump and motor involves ensuring proper positioning and parallelism to optimize performance and prevent damage.
Start by checking the alignment specifications provided by the pump and motor manufacturers.
Use alignment tools such as dial indicators, laser alignment systems, or reverse indicator method.
Ensure the pump and motor shafts are clean and free from any debris or damage.
Check and adjust the motor and...
The purpose of a gear box is to transmit and control power between the engine and the wheels or other driven components.
Transmits power from the engine to the wheels or other driven components
Provides torque multiplication and speed reduction
Allows for the selection of different gear ratios to optimize performance
Enables the vehicle to operate at different speeds and handle various loads
Protects the engine and drivetra
Top trending discussions
I appeared for an interview in Mar 2024.
I have 8 years of experience working as a Shift Engineer in various industries.
I have 8 years of experience as a Shift Engineer
Worked in various industries such as manufacturing, energy, and facilities management
Experience in troubleshooting, maintenance, and operation of equipment
Familiar with safety regulations and protocols
Led teams in shift operations and coordinated with other departments
We used air circuit breakers in my previous company.
We used air circuit breakers for their reliability and ease of maintenance.
Air circuit breakers are commonly used in industrial settings for their high breaking capacity.
Examples of air circuit breaker brands we used include Siemens and Schneider Electric.
Circuit breaker rating refers to the maximum current that the breaker can safely interrupt without causing damage.
Circuit breaker rating is typically expressed in amps (e.g. 15A, 20A, 30A).
The rating should be chosen based on the maximum current that will flow through the circuit.
It is important to select a circuit breaker with a rating higher than the maximum current to prevent tripping.
Using a circuit breaker with a ...
Cycle breaker maintenance involves regular inspection, testing, and replacement of components to ensure proper functioning.
Inspecting for signs of wear or damage
Testing functionality with appropriate equipment
Replacing faulty components as needed
Following manufacturer's guidelines for maintenance schedule
Keeping detailed records of maintenance activities
I applied via Company Website and was interviewed before Mar 2022. There were 2 interview rounds.
I applied via Walk-in and was interviewed in Aug 2024. There was 1 interview round.
33 kV to 220 SLD refers to a switchgear system for electrical distribution at medium voltage levels.
33 kV to 220 SLD likely refers to a switchgear system designed to handle voltages between 33 kV and 220 kV.
SLD stands for Single Line Diagram, which is a schematic representation of the electrical distribution system.
This switchgear system would be used for distributing electricity from a higher voltage transmission syst...
ACB stands for Air Circuit Breaker and VCB stands for Vacuum Circuit Breaker.
ACB is a type of circuit breaker that operates in the air where the arc is drawn in the air and extinguished using air.
VCB is a type of circuit breaker that operates in a vacuum where the arc is drawn in a vacuum and extinguished using vacuum.
ACBs are commonly used in low voltage applications while VCBs are used in medium voltage applications.
...
posted on 24 Jun 2021
I applied via Walk-in and was interviewed before Jun 2020. There was 1 interview round.
I appeared for an interview before Feb 2024.
I applied via Approached by Company and was interviewed in Apr 2022. There were 2 interview rounds.
Bukolze relays are used in electrical engineering for their high reliability and ability to handle high voltage and current.
Bukolze relays are known for their robustness and durability.
They are commonly used in power systems and industrial applications.
These relays can handle high voltage and current levels, making them suitable for heavy-duty operations.
They provide reliable switching and protection in electrical circ...
CT and PT are used in electrical engineering for measurement and protection purposes.
CT (Current Transformer) is used to measure high currents and step them down to a level suitable for measurement instruments.
PT (Potential Transformer) is used to measure high voltages and step them down to a level suitable for measurement instruments.
CTs and PTs are also used for protection purposes, such as detecting faults and isola...
The number of transformer production varies depending on the company and market demand.
The number of transformer production is influenced by factors such as market demand, company size, and production capacity.
Large transformer manufacturers may produce thousands of transformers per year.
Smaller companies or custom transformer manufacturers may have lower production volumes.
The production volume can also vary based on ...
There are several types of breakers used in electrical engineering.
Circuit breakers are used to protect electrical circuits from overloads and short circuits.
Some common types of breakers include thermal, magnetic, and hydraulic-magnetic breakers.
Thermal breakers use a bimetallic strip to detect excessive heat and trip the circuit.
Magnetic breakers use a solenoid to detect high currents and trip the circuit.
Hydraulic-m...
I applied via Recruitment Consultant and was interviewed in Apr 2021. There were 3 interview rounds.
Facility Manager
220
salaries
| ₹4.2 L/yr - ₹13 L/yr |
Assistant Manager
206
salaries
| ₹2 L/yr - ₹10.5 L/yr |
Facility Executive
202
salaries
| ₹1.8 L/yr - ₹5.5 L/yr |
Shift Engineer
190
salaries
| ₹1.8 L/yr - ₹6 L/yr |
Assistant Facility Manager
170
salaries
| ₹2.7 L/yr - ₹9 L/yr |
ISS Facility Services
Compass Group Support Services
BVG India
Leadec India