I applied via Company Website and was interviewed in Apr 2023. There were 3 interview rounds.
Apply MF on reading when CTR 1200/1 and Analog Ammeter 125/1.
Calculate the multiplication factor (MF) using the formula MF = CTR / Ammeter rating
In this case, MF = 1200 / 125 = 9.6
Apply the MF to the reading obtained from the ammeter to get the actual current
For example, if the ammeter reading is 50, the actual current would be 50 x 9.6 = 480A
SPRS types include Kramer and Scherbius drive. The difference lies in their power factor correction methods.
SPRS stands for Static Phase Reversal Switch
Kramer drive uses capacitors to correct power factor
Scherbius drive uses a transformer to correct power factor
Kramer drive is more efficient for low power applications
Scherbius drive is more efficient for high power applications
Relay setting and coordination involves ensuring proper functioning and communication between different relays.
Relay setting involves configuring the relay to operate at the desired current and voltage levels.
Coordination involves ensuring that the relays communicate with each other to prevent false tripping or failure to trip during a fault.
REM, REF, and Micom are types of relays commonly used in power systems.
Proper ...
I applied via Company Website and was interviewed before May 2022. There were 3 interview rounds.
I applied via Company Website and was interviewed in Oct 2020. There were 4 interview rounds.
Top trending discussions
I applied via Recruitment Consultant and was interviewed in Jun 2019. There were 3 interview rounds.
Concrete mix design involves determining the proportions of ingredients to create a specific concrete mixture.
The mix design process considers factors such as strength, workability, and durability.
Ingredients typically include cement, water, aggregates, and admixtures.
The proportions of each ingredient are determined based on the desired properties of the concrete and the specific application.
For example, a mix designe...
I applied via Company Website and was interviewed in Nov 2019. There were 3 interview rounds.
I applied via Approached by Company and was interviewed before Mar 2021. There was 1 interview round.
I applied via Company Website and was interviewed before Jan 2021. There were 4 interview rounds.
Fcao affects the setting time, strength, and durability of cement.
Fcao (free lime) is a byproduct of cement hydration.
Excess fcao can lead to delayed setting time and reduced strength.
Insufficient fcao can result in quick setting and decreased durability.
Optimal fcao content ensures proper hydration and desired cement properties.
Some of the top questions asked at the Shree Cement Assistant Manager interview for experienced candidates -
based on 2 interviews
2 Interview rounds
based on 111 reviews
Rating in categories
Assistant Manager
390
salaries
| ₹0 L/yr - ₹0 L/yr |
Deputy Manager
316
salaries
| ₹0 L/yr - ₹0 L/yr |
Officer
283
salaries
| ₹0 L/yr - ₹0 L/yr |
Senior Engineer
280
salaries
| ₹0 L/yr - ₹0 L/yr |
Assistant Officer
255
salaries
| ₹0 L/yr - ₹0 L/yr |
UltraTech Cement
Ambuja Cements
ACC
The Ramco Cements