Filter interviews by
I applied via Company Website and was interviewed before Jan 2024. There were 4 interview rounds.
Yes, I have experience operating technically advanced concrete batching plants.
Experience operating computerized batching systems
Knowledge of PLC programming and troubleshooting
Familiarity with advanced control systems like SCADA
Ability to interpret technical drawings and schematics
Experience with calibration and maintenance of sensors and instruments
The plant technically refers to the equipment and machinery used in the concrete batching process.
Understanding the operation of various components such as mixers, conveyors, and control systems
Knowledge of maintenance procedures to ensure optimal performance
Ability to troubleshoot technical issues and make necessary adjustments
Familiarity with safety protocols and regulations in operating the plant
Anything as per Batching plant oparetor Maintenance
Top trending discussions
posted on 18 Dec 2023
A batching plant is a facility where ingredients for concrete are mixed and blended together to produce concrete of desired quality.
Batching plants are used in construction projects to produce concrete in large quantities
Ingredients such as cement, water, aggregates, and admixtures are mixed in specific proportions
The plant ensures consistent quality and strength of the concrete produced
Different types of batching plan...
I applied via Walk-in and was interviewed in Oct 2023. There was 1 interview round.
ELCB stands for Earth Leakage Circuit Breaker and MCB stands for Miniature Circuit Breaker.
ELCB is a safety device used to protect against electrical shock caused by earth faults.
MCB is a type of circuit breaker that automatically switches off electrical circuits during abnormal conditions.
ELCB detects current leakage to earth and disconnects the circuit, while MCB protects against overloads and short circuits.
MCB (Miniature Circuit Breaker) provides overload protection by automatically switching off the circuit when current exceeds the rated capacity.
MCB trips when current exceeds its rated capacity to prevent overheating and potential fire hazards.
Overload protection is essential to protect electrical appliances and wiring from damage.
Examples of MCB overload protection include tripping when too many devices are connected ...
posted on 22 Apr 2024
posted on 26 Jan 2022
I applied via Naukri.com and was interviewed in Sep 2021. There was 1 interview round.
I applied via Walk-in and was interviewed in Sep 2023. There were 2 interview rounds.
I applied via Newspaper Ad and was interviewed in Mar 2024. There were 2 interview rounds.
Glanding termination
Sefty test safety code
I electrical good work All electrical Equipment and HT and LT Breker And 3.3 kv SF6 Breker transformer work and 440 volt terminition work cable jointing work
ALL ELECTRICAL WORK HT LT Breker VCB ACB CT GO and Transformer etc
based on 1 interview
Interview experience
Deputy Manager
609
salaries
| ₹6 L/yr - ₹16.5 L/yr |
Senior Engineer
429
salaries
| ₹4 L/yr - ₹12 L/yr |
Construction Engineer
301
salaries
| ₹3 L/yr - ₹9 L/yr |
Civil Site Engineer
231
salaries
| ₹1.8 L/yr - ₹9 L/yr |
Civil Supervisor
224
salaries
| ₹1.5 L/yr - ₹5.6 L/yr |
Tata Group
Reliance Industries
Adani Group
Mahindra & Mahindra