Filter interviews by
Clear (1)
I was interviewed in Aug 2024.
Methods for identifying and resolving defects in HPDC include visual inspection, X-ray analysis, and process optimization.
Visual inspection of castings for surface defects such as porosity, shrinkage, and cracks.
X-ray analysis to detect internal defects like gas porosity, inclusions, and shrinkage.
Process optimization through simulation software to identify potential defects before production.
Adjusting die temperature,...
Various methods such as X-ray diffraction, dilatometry, and microscopy can be used to determine parameters in metal injection molding.
X-ray diffraction can be used to analyze the crystal structure and phase composition of the material.
Dilatometry can measure the dimensional changes of the material during heating and cooling processes.
Microscopy techniques like SEM and TEM can provide detailed information on the microst...
Methods for determining the criticality of casting in part drawing
Consider the function of the part in the overall assembly
Evaluate the consequences of failure of the casting
Assess the complexity of the casting design and its impact on performance
Utilize simulation software to analyze stress distribution and potential failure points
Consult with experienced engineers or casting specialists for their input
Post-processing involves refining and enhancing data or images after initial processing.
Post-processing can involve adjusting brightness, contrast, and color levels.
It can also include removing noise or artifacts from the data.
Post-processing may involve applying filters or algorithms to enhance specific features.
Post-processing is commonly used in photography, medical imaging, and scientific data analysis.
Top trending discussions
I was interviewed before May 2021.
I applied via Approached by Company
I applied via Recruitment Consulltant and was interviewed before Apr 2022. There were 3 interview rounds.
posted on 24 Jul 2023
I applied via Approached by Company and was interviewed before Jun 2023. There were 4 interview rounds.
I was interviewed before May 2016.
I applied via Company Website
TTR stands for Total Thickness Range and is required for powder coating process to ensure proper adhesion and durability.
TTR is the range of thickness of the substrate and any coatings applied to it
It is important for powder coating as it ensures proper adhesion and durability
If the TTR is too large, the coating may not adhere properly or may crack and peel over time
Examples of substrates with varying TTR include alumi
Detection and prevention poka-yoke refers to the use of techniques to identify and prevent errors in a process.
Poka-yoke is a Japanese term for mistake-proofing
Detection poka-yoke involves identifying errors as they occur
Prevention poka-yoke involves designing processes to prevent errors from occurring
Examples of poka-yoke include using checklists, color-coding, and physical barriers
Poka-yoke can improve quality, reduc
Decrease in pH can occur due to various factors in conversion coating.
Decrease in pH can be caused by the addition of an acid or acidic solution.
Presence of reactive metals in the coating can lead to a decrease in pH.
Contamination by organic materials or impurities can also lower the pH.
Chemical reactions during the conversion coating process may result in pH decrease.
Examples of conversion coatings include phosphating
To prepare 0.1 N H2SO4 & NaOH, calculate the required amount of solute and dissolve it in distilled water.
Calculate the molar mass of H2SO4 and NaOH
Determine the required amount of solute using the formula: N = (W/M) x (1000/V)
Dissolve the calculated amount of solute in distilled water to make 1 liter of solution
Standardize the solution using a primary standard
Use a burette to measure the volume of solution needed for
To cross verify 0.1 normality H2SO4, use a standard solution of NaOH and an indicator.
Prepare a standard solution of NaOH of known concentration.
Add a few drops of an indicator such as phenolphthalein to the H2SO4 solution.
Titrate the H2SO4 solution with the NaOH solution until the endpoint is reached.
The endpoint is when the indicator changes color, indicating that all the H2SO4 has reacted with the NaOH.
Calculate the...
Prepare a pH buffer solution as per defined standard in tablet.
Determine the required pH value and buffer capacity
Select the appropriate buffer system and calculate the required amounts of buffer components
Dissolve the buffer components in water and adjust the pH as necessary
Check the pH and adjust if necessary
Filter the solution and store in a clean container
Use a calibrated pH meter to verify the pH of the solution
Some of the top questions asked at the Rico Auto Industries Researcher interview -
based on 1 interview
Interview experience
Assistant Manager
294
salaries
| ₹0 L/yr - ₹0 L/yr |
Associate Engineer
220
salaries
| ₹0 L/yr - ₹0 L/yr |
Deputy Manager
209
salaries
| ₹0 L/yr - ₹0 L/yr |
Manager
101
salaries
| ₹0 L/yr - ₹0 L/yr |
Supervisor
72
salaries
| ₹0 L/yr - ₹0 L/yr |
UNO Minda
Bharat Forge
TVS Sundram Fasteners
Samvardhana Motherson Group